6.3
POSITIONING
CLEARANCE REQUIREMENTS
This unit must be installed in accordance with the clearances shown on the rating label which is adhered to the
unit.
CLEARANCES
Combustible construction Noncombustible construction
Back
6" (152 mm)
6" (152 mm)
Right Side
25" (635 mm)
25" (635 mm)
Left Side
0"
0"
"Suitable for installation on combustible floors"
There are no particular prescriptions regarding side distances from other appliances or walls, however it is
advisable to leave enough space (20/30 “ : 50/70 cm) in case of maintenance and/or repairs.
The appliance must stand level.
Small differences in level can be eliminated by screwing or
unscrewing the adjustable feet.
A significantly uneven or sloping stance can affect the
operation of the appliance adversely.
Adjust the bottom foot on each leg to overcome an uneven floor.
The appliance must be fixed to the floor. See drawing for correct position.
-
Mark hole locations on floor through anchoring holes provided in posterior flanged adjustable feet.
-
Remove unit and drill holes where marked and insert expansion shields to accommodate 5/16" size
lag bolts.
-
Reposition unit. Re-level kettle by making necessary adjustments on flanged feet.
-
Bolt down unit and seal with Silastic or equivalent sealing compound. Sealant must be applied not only
to bolt heads but also around flanges making contact with the floor surface to fulfil NSF requirements.
Wipe off excess sealant immediately.
If the appliance is equipped with casters (optional), leveling must be ensured by the floor. If
the floor is not level, it must be made such with thicknesses in correspondence of the wheels.
The surface and the inclination of the shims must be such as not to affect the stability of the
machine.
After positioning remove the anterior bar under the frame.
It is advisable to keep the bar so that they are available for subsequent movements.