Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or 

ducts. You must provide two permanent openings: 

one within 12" of the ceiling and one within 12" 

of the floor. Connect these items directly to the 

outdoors or spaces open to the outdoors. These 

spaces include attics and crawl spaces. Follow the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, 

Section 5.3, Air for Combustion and Ventilation

 for 

required size of ventilation grills or ducts.

IMPORTANT:

 Do not provide openings for inlet 

or outlet air into attic if attic has a thermostat-

controlled power vent. Heated air entering the attic 

will activate the power vent.

AIR FOR COMBUSTION 

AND VENTILATION

Continued

Figure 3 - Ventilation Air from Outdoors

Figure 2 - Ventilation Air from Inside 

Building

Outlet
Air

Ventilated
Attic 

Outlet
Air

Inlet
Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Or

Remove

Door into
Adjoining

Room,
Option

3

Ventilation Grills 

Into Adjoining Room,

Option 2

Ventilation

Grills Into

Adjoining 

Room,

Option 1

12"

12"

INSTALLATION

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install this heater as your primary 

heating  source.  If  you  have  a 

central heating system, you may 

run system's circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In event of a power out

-

age, you can use this heater as 

your primary heat source.

 WARNING: A qualified ser

-

vice person must install heater. 

Follow all local codes.

NOTICE: State or local codes may 

only allow operation of this appli

-

ance  in  a  vented  configuration. 

Check your state or local codes.

  WARNING:  Make  sure  the 

selector switch is in the OFF po

-

sition before installing heater.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo

-

sote, ashes and loose paint by a 

qualified chimney cleaner. Creo

-

sote will ignite if highly heated. A 

dirty chimney flue may create and 

distribute soot within the house. 

Inspect chimney flue for damage. 

If damaged, repair flue damper 

before operating appliance.

Содержание VFRMV18NB

Страница 1: ...y phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and serv...

Страница 2: ...in which it is installed Provi sions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 6 of this manual This appliance may be in...

Страница 3: ...manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING Do not use a blower insert heat exchanger...

Страница 4: ...er SAFETY INFORMATION Continued 7 Topreventthecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 20 8 Before using furniture polish wax carpet cleaner or similar products turn heat...

Страница 5: ...four optional remote controls that can be purchased separately Wall switch Hand held ON OFF remote Wall thermostat Hand held thermostat remote See Accessories page 26 Thewallthermostatorhand heldtherm...

Страница 6: ...ide additional fresh air Unusually tight construction is defined as construction where a Walls and ceilings exposed to the out side atmosphere have a continuous water vapor retarder with a rating of o...

Страница 7: ...ON Continued The space in the previous example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your optio...

Страница 8: ...ion Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Installation NOTICE This heater is intended for use as supplemental heat Use this heater along with your p...

Страница 9: ...ane LP for your unit If your gas supply is not correct do not install in fireplace Call dealer where you bought the appliance for proper type of appliance Installation Continued WARNING This appliance...

Страница 10: ...al A Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace If Using Mantel Youmusthavenoncombustiblematerial s abovethe fireplace opening Noncombustible materials such as slate marble...

Страница 11: ...inimum clearances shown in this manual Notice Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following operate the logs only with the flue damper open and damper...

Страница 12: ...damper clamp will keep damper open Installation instructions are included with clamp accessory Figure 10 Attaching Damper Clamp Damper Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Damp...

Страница 13: ...l codes Propane LP Supply Tank External Regulator Figure 13 External Regulator With Vent Pointing Down Vent Pointing Down CAUTION Never connect propane LP fireplace directly to the propane LP supply T...

Страница 14: ...lve from your dealer See Accessories page 26 Minimum inlet pressure for purpose of input adjustment Figure 14 Gas Connection Remote Ready Models Only To Gas Control Valve 3 Minimum Sediment Trap Propa...

Страница 15: ...as or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LPsup ply to e...

Страница 16: ...r Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If...

Страница 17: ...knob If control knob does not pop out when released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 OPERATING HEATER Continued Figure 18...

Страница 18: ...ration On Off Series Model HRC100 Hold the control button on the hand held remote until burner turns on Hold the con trol button again until burner turns off see Figure 21 To Lock press both buttons o...

Страница 19: ...G HEATER Continued Key Pad Lock Feature This feature allows the user to lock unlock the keypad on the hand held remote in the MANU or AUTO mode to prevent inadvertent operation i e children operating...

Страница 20: ...keep control areas burners and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need mor...

Страница 21: ...th the unit off lightly blow air through the air inlet hole in the same direction as gas flow You may blow through a drinking straw if compressed air is not available This hole is accessible from the...

Страница 22: ...ne LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tightennuthold...

Страница 23: ...rol knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas compan...

Страница 24: ...2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see pages 9 through 12 4 Clean burners see...

Страница 25: ...logged 1 Gas leak See warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between con trol valve and burner 2 Gas leak See warning statement at top of page 1 Han...

Страница 26: ...rgaspressureistoolow Ifso con tact your local propane LP or natural gas supplier Accessories Purchase these heater accessories from your local dealer If they can not supply these accessories call DESA...

Страница 27: ...6CA FB42C SERIES CIRCULATING FB36NCA FB42NC SERIES NON CIRCULATING blower Not Shown For all models DAMPER CLAMP GA6080 Not Shown For all models Permanently opens chimney flue damper for vented operati...

Страница 28: ...www desatech com 116412 01C 28 Illustrated Parts Breakdown Models VFRMV18NB VFRMV18PB VFRMV24NB Shown and VFRMV24PB 1 4 5 3a 3b 6 9 11 2 12 13 16 18 8 19 22 7 10 20 17 14 15...

Страница 29: ...3 8 1 8 14396 Adapter 1 9 111804 01 Burner 1 111804 03 Burner 1 10 111819 04 Orifice 1 111819 05 Orifice 1 111819 14 Orifice 1 111819 15 Orifice 1 11 111807 01 Valve 1 111807 02 Valve 1 12 111796 01 V...

Страница 30: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 32: ...er in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fa...

Отзывы: