Firewerks VFRMV18NB Скачать руководство пользователя страница 17

www.desatech.com

116412-01C

1

4.  Press in and turn control knob clockwise 

 to the OFF position (see Figure 18).

  WARNING:  Burners  will 

come  on  automatically  within 

one  minute  when  the  switch 

is  in  the  ON  position  after  the 

pilot is lit.

5.  Wait five (5) minutes to clear out any gas. 

Then smell for gas, including near the floor. 

If you smell gas, STOP! Follow “B” in the 

safety information in column 1, page 16. If 

you don’t smell gas, go to the next step.

6.  Press in and turn control knob counter-

clockwise 

 to the PILOT position. 

Press in control knob for five (5) seconds 

(see Figure 18).

 

Note:

 You may be running this heater for 

the first time after hooking up to gas sup

-

ply. If so, the control knob may need to be 

pressed in for 30 seconds or more. This will 

allow air to bleed from the gas system.

7.  With control knob pressed in, press and 

release ignitor button. This will light pilot. 

The pilot is attached to the front burner. If 

needed, keep pressing ignitor button until 

pilot lights.

 

Note:

 If pilot does not stay lit, contact a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. To light pilot with match, see 

Manual Lighting Procedure

, page 18.

8.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

• If control knob does not pop out when 

released, contact a qualified service person 

or gas supplier for repairs.

 

Note:

 If pilot goes out, repeat steps 4 

through 8.

OPERATING HEATER

Continued

Figure 18 - Control Knob and Ignitor 

Button Location, Manual Controlled

9.  Slightly push in and turn control knob coun-

terclockwise 

 to the ON position.

10.  Wait one minute and switch selector switch 

to the ON position to light burners. 

Note:

 

AUTO  is  only  functional  when  using 

GWMT1 or GWMS2 optional accessories.

11.  Set flame adjustment knob to any level 

between HI and LO.

12.  To leave pilot lit and shut off burners only: 

turn control knob clockwise 

 to the 

PILOT  position,  or  use  remote  control 

manual OFF button, or set selector switch 

in the OFF position.

 CAUTION: Do not try to ad

-

just heating levels by using the 

equipment shutoff valve.

  WARNING:  Make  sure  the 

selector  switch  is  in  the  OFF 

position  when  you  are  away 

from home for long periods of 

time. Heater will come on auto

-

matically with selector switch in 

the ON position.

Figure 19 - Pilot

Ignitor 
Electrode

Pilot 
Burner

Natural

Ignitor 
Electrode

Pilot 
Burner

Propane/LP

TO TURN OFF GAS 

TO APPLIANCE

Shutting Off Heater

1.  Turn control knob clockwise 

 to the 

OFF position.

2a.  Set selector switch in the OFF position.

2b. 

If Using Optional Hand-Held Remote:

 Set se-

lector switch in the OFF position to prevent 

draining battery.

3.  Close equipment shutoff valve (see Figure 

15, page 15).

Piezo Ignitor

Switch 

Control Knob

Flame Adjustment Knob

Содержание VFRMV18NB

Страница 1: ...y phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and serv...

Страница 2: ...in which it is installed Provi sions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 6 of this manual This appliance may be in...

Страница 3: ...manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING Do not use a blower insert heat exchanger...

Страница 4: ...er SAFETY INFORMATION Continued 7 Topreventthecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 20 8 Before using furniture polish wax carpet cleaner or similar products turn heat...

Страница 5: ...four optional remote controls that can be purchased separately Wall switch Hand held ON OFF remote Wall thermostat Hand held thermostat remote See Accessories page 26 Thewallthermostatorhand heldtherm...

Страница 6: ...ide additional fresh air Unusually tight construction is defined as construction where a Walls and ceilings exposed to the out side atmosphere have a continuous water vapor retarder with a rating of o...

Страница 7: ...ON Continued The space in the previous example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the space can support You must provide additional fresh air Your optio...

Страница 8: ...ion Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Installation NOTICE This heater is intended for use as supplemental heat Use this heater along with your p...

Страница 9: ...ane LP for your unit If your gas supply is not correct do not install in fireplace Call dealer where you bought the appliance for proper type of appliance Installation Continued WARNING This appliance...

Страница 10: ...al A Figure 5 Heat Resistant Material Slate Marble Tile etc Above Fireplace If Using Mantel Youmusthavenoncombustiblematerial s abovethe fireplace opening Noncombustible materials such as slate marble...

Страница 11: ...inimum clearances shown in this manual Notice Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following operate the logs only with the flue damper open and damper...

Страница 12: ...damper clamp will keep damper open Installation instructions are included with clamp accessory Figure 10 Attaching Damper Clamp Damper Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Damp...

Страница 13: ...l codes Propane LP Supply Tank External Regulator Figure 13 External Regulator With Vent Pointing Down Vent Pointing Down CAUTION Never connect propane LP fireplace directly to the propane LP supply T...

Страница 14: ...lve from your dealer See Accessories page 26 Minimum inlet pressure for purpose of input adjustment Figure 14 Gas Connection Remote Ready Models Only To Gas Control Valve 3 Minimum Sediment Trap Propa...

Страница 15: ...as or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LPsup ply to e...

Страница 16: ...r Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If...

Страница 17: ...knob If control knob does not pop out when released contact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 OPERATING HEATER Continued Figure 18...

Страница 18: ...ration On Off Series Model HRC100 Hold the control button on the hand held remote until burner turns on Hold the con trol button again until burner turns off see Figure 21 To Lock press both buttons o...

Страница 19: ...G HEATER Continued Key Pad Lock Feature This feature allows the user to lock unlock the keypad on the hand held remote in the MANU or AUTO mode to prevent inadvertent operation i e children operating...

Страница 20: ...keep control areas burners and circulating air passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need mor...

Страница 21: ...th the unit off lightly blow air through the air inlet hole in the same direction as gas flow You may blow through a drinking straw if compressed air is not available This hole is accessible from the...

Страница 22: ...ne LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tightennuthold...

Страница 23: ...rol knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas compan...

Страница 24: ...2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see pages 9 through 12 4 Clean burners see...

Страница 25: ...logged 1 Gas leak See warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between con trol valve and burner 2 Gas leak See warning statement at top of page 1 Han...

Страница 26: ...rgaspressureistoolow Ifso con tact your local propane LP or natural gas supplier Accessories Purchase these heater accessories from your local dealer If they can not supply these accessories call DESA...

Страница 27: ...6CA FB42C SERIES CIRCULATING FB36NCA FB42NC SERIES NON CIRCULATING blower Not Shown For all models DAMPER CLAMP GA6080 Not Shown For all models Permanently opens chimney flue damper for vented operati...

Страница 28: ...www desatech com 116412 01C 28 Illustrated Parts Breakdown Models VFRMV18NB VFRMV18PB VFRMV24NB Shown and VFRMV24PB 1 4 5 3a 3b 6 9 11 2 12 13 16 18 8 19 22 7 10 20 17 14 15...

Страница 29: ...3 8 1 8 14396 Adapter 1 9 111804 01 Burner 1 111804 03 Burner 1 10 111819 04 Orifice 1 111819 05 Orifice 1 111819 14 Orifice 1 111819 15 Orifice 1 11 111807 01 Valve 1 111807 02 Valve 1 12 111796 01 V...

Страница 30: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 32: ...er in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fa...

Отзывы: