Safety Distances from Combustible Surfaces:
Side/Front
Top
HD Insert 4KW Stove
275mm*
275mm
*The HD Insert 4KW stove can be situated 200mm from the side of a wooden fireplace
mantel if the mantel is flush (or less deep) with the front of the appliance
Commissioning and Handover
Upon completion of the installation, allow a suitable period of time for any fire cement
and mortar to dry out. A small fire may then be lit and checked to ensure the smoke and
fumes are taken from the stove up the chimney and emitted safely to atmosphere. Do not
run the stove at full output for at least 3 – 4 days.
On completion of the installation and commissioning, ensure that the operating
instructions and operating tools for the stove are left with the customer. Ensure to advise
the customer on the correct use of the appliance with the fuels likely to be used on the
stove and warn them to use only the recommended fuels for the stove.
Advise the user on what to do should smoke or fumes be emitted from the stove. The user
should use a suitable fireguard in the presence of children, aged and/or infirm persons.
HD Insert 4KW
Wood
Solid Fuel
Nominal heat output:
kW
4.3
3.9
Efficiency
%
80.9
75.3
CO Emissions (@13% O
2)
%
0.67
0.56
Appliance weight:
kg
82
82
Flue gas mass flow:
g/s
2.9
3.8
*Flue Temp:
°C
215
162
*under nominal heat output