FIREPOWER TIG 200 AC/DC
INSTALLATION
3-12
Manual 0-5370
Installation
Adjust programming parameter using
the Multi Function Control knob
Press to go forward / go back between
programming status LED’s
A-12717
Figure 3-6: LIFT TIG and HF TIG Programming Mode
Programming Parameter
Adjustment Device
Display
Pre-Flow
This parameter operates in
TIG modes only and is used to
provide gas to the weld zone
prior to striking the arc, once
the torch trigger switch has been
pressed. This control is used to
dramatically reduce weld porosity
at the start of a weld.
V
SEC
%
Hz
Volts
0.0 to 1.0 second
Initial Current
This parameter operates in (4T)
TIG modes only and is used to
set the start current for TIG. The
Start Current remains on until the
torch trigger switch is released
after it has been depressed.
Note: The maximum initial current
available will be limited to the set
value of the weld current.
Amps
5 to 200 Amps (DC TIG mode)
30 to 200 Amps (AC LIFT TIG mode)
10 to 200A (AC HF TIG mode)
Up Slope
This parameter operates in (4T)
TIG modes only and is used to
set the time for the weld current
to ramp up, after the torch trigger
switch has been pressed then
released, from Initial Current to
High or Weld current.
V
SEC
%
Hz
Volts
0.0 to 15.0 seconds
Содержание TIG 200 AC/DC
Страница 6: ...This Page Intentionally Blank...
Страница 74: ...FIREPOWER TIG 200 AC DC APPENDIX A 2 Manual 0 5370 Appendix APPENDIX 2 200 AC DC SETUP GUIDE...
Страница 75: ...APPENDIX FIREPOWER TIG 200 AC DC Manual 0 5370 A 3 Appendix A 12718...
Страница 76: ...FIREPOWER TIG 200 AC DC APPENDIX A 4 Manual 0 5370 Appendix This Page Blank Intentionally...
Страница 77: ...This Page Intentionally Blank...