Firepower FP 95 Скачать руководство пользователя страница 27

SERVICE 

FIREPOWER FP 95 FC

Service 5-3 

Manual 0-5122

5.05  Power Source Problems

    FAULT  

    CAUSE  

    REMEDY  

  1  

Primary line voltage is ON. 
Welding arc can not be 
established.  

A  Primary fuse is blown.

A Replace primary fuse. 

B Broken connection in primary 

circuit.

B Have an Accredited ESAB Service Agent check primary circuit.

  2  

Primary line voltage is ON 
but when the MIG Gun 
trigger switch is depressed 
nothing happens.

   MIG Gun trigger switch leads are 

disconnected.

   Reconnect.

  3  

Primary line voltage is ON, 
no wire feed but gas flows 
from the MIG Gun when 
the torch trigger switch is 
depressed.

A Electrode wire stuck in wire liner 

or contact tip (burn-back jam).

A Check for clogged / kinked MIG Gun wire liner or worn contact 

tip. Replace faulty component(s).

B Faulty control PCB

B Have an Accredited ESAB Service Agent investigate the fault.

  4  

Wire feeds when the MIG 
Gun trigger switch is de-
pressed but arc can not be 
established.

Poor or no work lead connection.

Clean work clamp area and ensure good electrical contact.

  5  

Jerky wire feed

A Worn or dirty contact tip

A Replace

B Worn feed roller.

B Replace

C Excessive back tension from 

wire reel hub.

C Reduce brake tension on spool hub

D Worn, kinked or dirty conduit 

liner

D Clean or replace conduit liner

6

Thermal Overtemp Light 
is ON and Fan motor is 
running

The machine duty cycle has 
been exceeded.

Allow the fan to run so machine can cool down. When light 
goes out, welding may resume.

7

Thermal Overtemp Light 
turns on in less than 30 
seconds during welding.

Fan has stopped running or fuse 
on PCB has blown

Have an Accredited ESAB Service Agent replace the fuse.

Table 5-2: Power Source Problems

Содержание FP 95

Страница 1: ...Firepower FP 95 FLUX CORED WELDER R vision AB Issue Date April 8 2016 Manual No 0 5122 Operating Manual www firepoweronline com A 13015...

Страница 2: ...re please take the time to read the entire manual especially the Safety Precautions They will help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY...

Страница 3: ...or in part without written permission of the publisher is prohibited The publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused by any error or omissio...

Страница 4: ...reof contained in this manual and accom panying labels and or inserts when installed operated maintained and repaired in accordance with the instructions provided This equipment must be checked period...

Страница 5: ...lling Wire Spool 3 1 3 07 Feedrolls 3 2 3 08 Install Wire into the Feedhead 3 2 3 09 Install Wire into the Welding Gun 3 3 SECTION 4 OPERATION 4 1 4 01 General Safety Precautions 4 1 4 02 Firepower Co...

Страница 6: ...TABLE OF CONTENTS APPENDIX 1 OPTIONS AND ACCESSORIES A 1 APPENDIX 2 POWER SUPPLY REPLACEMENT PARTS A 2 APPENDIX 3 FIREPOWER FP 95 FC SYSTEM SCHEMATIC A 4 REVISION HISTORY A 6...

Страница 7: ...started up no one is unprotected when the arc is struck 3 The workplace must be suitable for the purpose be free from drafts 4 Personal safety equipment Always wear recommended personal safety equipm...

Страница 8: ...filter lens and wear protective clothing Protect bystanders with suitable screens or curtains FIRE HAZARD Sparks spatter can cause fire Make sure therefore that there are no inflammable ma terials nea...

Страница 9: ...t g es lorsque l arc est amorc 3 Le lieu de travail doit tre am nag convenablement pour acqu rir le mat riel en toute s curit libre de courants d air 4 quipement de s curit personnelle Vous devez touj...

Страница 10: ...INCENDIE Les tincelles projections peuvent causer un incendie Assurez vous qu il n y a pas de mat riel inflammable proximit de l appareil BRUIT un bruit excessif peut endommager la capacit auditive Pr...

Страница 11: ...power web site listed below http www firepoweronline com 2 02 Equipment Identification The unit s identification number specification or part number model and serial number usually appear on a data ta...

Страница 12: ...8mm Table 2 1 System Specifications The recommended time delay fuse or circuit breaker size is 20 amp An individual branch circuit capable of carrying 30 am peres and protected by fuses or circuit br...

Страница 13: ...designed for 17 duty cycle at 85 amps This means that it has been designed and built to provide the rated amperage 85 amps for1 7 minutes out of every 10 minute period During the other 8 3 minutes of...

Страница 14: ...FIREPOWER FP 95 FC INTRODUCTION Manual 0 5122 2 4 Introduction This Page Intentionally Blank...

Страница 15: ...n conductor size and over current protection shall conform to the requirements of the local electrical code All installation wiring and machine connection shall be done by a competent electrician The...

Страница 16: ...ction 3 06 onto the hub so that the wire will feed off the spool as the spool rotates counter clockwise CAUTION Use care in handling the spooled wire as it will tend to unravel when loosened from the...

Страница 17: ...Wire into the Welding Gun 1 Plug the Welding Power Source into the 120VAC recep tacle WARNING ELECTRIC SHOCK CAN KILL With the gun switch located on the gun activated welding power is applied to the...

Страница 18: ...e contact tip and nozzle Cut the wire within 6mm from the nozzle WARNING The drive rollers when moving may crush the fingers Periodically check the drive rollers Replace them when they are worn and co...

Страница 19: ...ne into overtemp 2 The Wire Speed Control knob controls the welding current via the electrode wire feed rate i e the speed of the wire feed mo tor 3 The Voltage Power Switch selects between MIN and MA...

Страница 20: ...ION Manual 0 5122 4 2 Operation Art A 09064_AD Wire Speed Control On Off Switch Hi Low Powe Switch MIG Welding Torch Ground Cable Clamp Input Power Cable Wire Feeder Pressure Adjust Welding Wire Figur...

Страница 21: ...releasing the gun switch the electrode wire will remain electrically hot for several seconds 4 05 Basic Welding Technique General Two different welding processes are covered in this section with the i...

Страница 22: ...ld joint Hold the gun so that the welding seam is viewed at all times Always wear the welding helmet with proper filter lenses CAUTION Do not pull the welding gun back when the arc is established This...

Страница 23: ...ss the plate to the opposite edge NOTE When the equipment is properly adjusted a rapidly cracking or hissing sound of the arc is a good indicator of correct arc length 6 Practice stopping in the middl...

Страница 24: ...3_AB Steel Flux Core E71T GS None Required 030 0 8mm 035 0 9mm Material Type Wire Type Shielding Gas and Flow Rate Wire Size Diameter 24 ga 0 6mm 22 ga 0 7mm 20 ga 0 9mm 18 ga 1 2mm 16 ga 3mm 1 8 3 2m...

Страница 25: ...ch nozzle and the work piece a Keep the distance between the MIG torch nozzle and the work piece to a minimum 2 Inconsistent wire feed Wire feeding problems can be reduced by checking the following po...

Страница 26: ...sing the voltage selection switch or reduce wirespeed control 5 Irregular weld shape A Incorrect voltage and current settings Convex voltage too low Concave voltage too high A Adjust voltage and curre...

Страница 27: ...lace faulty component s B Faulty control PCB B Have an Accredited ESAB Service Agent investigate the fault 4 Wire feeds when the MIG Gun trigger switch is de pressed but arc can not be established Poo...

Страница 28: ...FIREPOWER FP 95 FC SERVICE Manual 0 5122 5 4 Service This Page Intentionally Blank...

Страница 29: ...re Feed Rolls MIG Gun Consumables Part No Description 1444 0427 Wire Feed Roll Knurle 023 030 035 0 6 0 8mm 0 9mm Hard Cored 1444 0050 Nozzle 1444 0026 Contact Tip 030 0 8mm 1444 0027 Contact Tip 035...

Страница 30: ...43 0025 10 FRONT FRAME FP 95 FC 1444 0829 11 HANDLE FP 95 FC HELV21600036 12 KIT SPOOL HOLDER FOR D 16 SPOOLS COMP 1444 0801 13 LEFT SIDE PANEL FP 95 FC W SILKS HELV05000363 14 LOWER PANEL FP 95 FC SI...

Страница 31: ...APPENDIX FIREPOWER FP 95 FC Appendix A 3 Manual 0 5122 20 13 11 23 6 17 4 19 14 8 16 21 7 18 22 12 25 1 5 24 2 3 Art A 09067_AD 10 15 9 Figure A 2 FP 95 FC Parts List Callouts...

Страница 32: ...FIREPOWER FP 95 FC APPENDIX Manual 0 5122 A 4 Appendix APPENDIX 3 FIREPOWER FP 95 FC SYSTEM SCHEMATIC Art A 09025_AB Figure A 3 FP 95 FC Simple System Schematic...

Страница 33: ...APPENDIX FIREPOWER FP 95 FC Appendix A 5 Manual 0 5122 This Page Intentionally Blank...

Страница 34: ...FIREPOWER FP 95 FC APPENDIX Manual 0 5122 A 6 Appendix Revision History Date Rev Description 03 19 2009 AA Manual release 04 08 2016 AB Rebrand updates part number art updates schematic updates...

Страница 35: ......

Страница 36: ...2 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 UKRAINE ESAB Ukraine LLC Kiev Tel 38 044 501 23 24 Fax 38...

Отзывы: