INSTALLATION
FIREPOWER FP 95 FC
Installation 3-3
Manual 0-5122
NOTE!
If there is too much pressure on the drive
roll the wire gets locked and the motor
could get damaged, If it is too loose the
wire will not feed properly.
Pressure Adjust Device
Pressure Arm
Art # A-09070 AB
Figure 3-4: Opening Pressure Arm
Pressure Adjust Device
Pressure Arm
Wire Spool
Wire
Feed Roll
Ar
t #
A
-0
90
71
_A
B
Figure 3-5: Inserting Wire
Art # A-09072_AB
Figure 3-6: Wire Installed
3.09 Install Wire into the Welding Gun
1. Plug the Welding Power Source into the 120VAC recep-
tacle.
!
WARNING
ELECTRIC SHOCK CAN KILL! With the gun
switch (located on the gun) activated,
welding power is applied to the output
terminals, feedroll, ground clamp, gun cable
connection and welding wire. Do not touch
these parts with the gun switch activated.
2. Turn the welding machine ON with the front panel Volt-
age Power Switch set to "Min"
MIN
MAX
Art # A-09073_AB
Figure 3--7: Power ON
3. Set the wire feed speed to half-way or "5".
MIN
MAX
Art # A-09073_AB
Figure 3-8: Wire Speed Half-way
4. Straighten the gun cable. Remove the nozzle and con-
tact tip from the MIG welding gun (see Section 2.08).