2.05 Specifications
Description
FP 125
FP 135
FP 165
Package System Part Number
1444-0324
1444-0326
1444-0328
Power Source Weight
47.4 lb (21.5 kg)
52.9 lb (24.0kg)
58.1 lb (26.4 kg)
Power Source Dimensions HxWxD
12 x 9.75 x 17.5" ( 304.8 x 247.7 x 444.5mm)
Number of Phases
1 Ø
Frequency
60Hz
Flexible Supply Cable Size
7 ft (2.2 m) 14AWG
7 ft (2.2 m) 14AWG
7.5 ft (2.5 m) 14AWG
Supply Lead Plug Type
5-15P
5-15P
6-50P
Nominal Input Voltage
120V AC
120V AC
230V AC
Rated kVA @ 100% Duty Cycle
5kVA
6kVA
7kVA
Rated Input Current
15A (60A@40%)
15A (60A@60%)
22.5A (120A@25%)
Maximum Input Current
38A (110A@10%)
50A (120A@13%)
35A (155A@15%)
Generator Requirements
# 5kVA
# 6kVA
# 7kVA
Supply VA @ max. output
# 4.6kVA
# 5kVA
# 6.8kVA
Open Circuit Voltage Range
16 – 30V
16 – 32V
15 – 30V
Output Current Range
40 – 125A
39 – 135A
36 – 165A
Duty Cycle Period
10 Minutes
Number of Output Voltage Values
4
Minimum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
15A (60A@40%)
15A (60A@60%)
22.5A (120A@25%)
Maximum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
38A (110A@10%)
50A (120A@13%)
35A (155A@15%)
Wire Size Range
Steel
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
Stainless Steel
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
Flux Core
.030” - .035”
(0.8 - 0.9mm)
.030” - .035”
(0.8 - 0.9mm)
.030” - .035”
(0.8 - 0.9mm)
Table 2-1: System Specifications
∆
The recommended time delay fuse or circuit breaker size is 20 amp. An individual branch circuit capable of carrying 30 am-
peres and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent
of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)
Firepower continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment
previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above spec-
ifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components,
installation location and conditions and local power grid supply conditions.
Содержание FP 95 FC
Страница 26: ...FIREPOWER FP 125 135 165 INSTALLATION 3 10 Manual 0 5123 This Page Intentionally Blank...
Страница 42: ...ESAB FIREPOWER FP 125 135 165 SERVICE 5 4 Manual 0 5123 This Page Intentionally Blank...
Страница 46: ...FIREPOWER FP 125 135 165 APPENDIX A 4 Manual 0 5123 APPENDIX 3 FIREPOWER 125 SYSTEM SCHEMATIC Art A 09022...
Страница 47: ...FIREPOWER FP 125 135 165 Manual 0 5123 A 5 APPENDIX APPENDIX 4 FIREPOWER 135 SYSTEM SCHEMATIC Art A 09023...
Страница 48: ...FIREPOWER FP 125 135 165 APPENDIX A 6 Manual 0 5123 APPENDIX 5 FIREPOWER 165 SYSTEM SCHEMATIC Art A 09024...
Страница 49: ...FIREPOWER FP 125 135 165 Manual 0 5123 A 7 APPENDIX This Page Intentiolnally Blank...
Страница 51: ......