CoolSmart TV
864, PB 42 Linear, PB 42 CF, 4415 HO
Sku# 98900779
Page 32 of 33
17602029- 9/24/19
© Travis Industries, Inc.
6. Re-attach the two rear mounting brackets (removed in step 6) to the bottom of the convection manifold.
Leave the screws loose so the brackets can be positioned to the back of the chase. Secure the brackets
to the chase using screws (not included). Tighten the screws securing the brackets to the manifold.
7. Stretch the included flex to its maximum length. Measure the distance between the starter collars on the
fireplace and the inlets on the convection manifold. Cut the flex to the appropriate length and install
between the fireplace and the manifold. Secure using (3) screws at every connection and seal the joints
with silicone caulk or aluminum (U.L. 181A-P) tape.
Self-Drilling
Screw