Finalizing the Installation
(for qualified installers only)
© Travis Industries
1/17/2019 – 1483-FR
864 31K CF Install
Conversion du foyer en aération arrière (suite)
Tuck the 3 pieces of insulation (included in the
rear vent conversion kit) into the area above the
exhaust manifold. The insulation must be placed
so it covers the entire area over the flue
assembly.
Attach the intake cover plate to
the top of the fireplace using the
screws removed earlier.
Bend the heat shield legs
downward as shown.
Remove the screws from the
top of the fireplace. Attach
the heat shield to the top of
the fireplace using these
screws.
Attach the vent cover plate to the
back of the fireplace using the
screws removed earlier.