Firenzo CONTESSA Скачать руководство пользователя страница 1

 

CI-2013-05-14 
 

Instructions for Installation 

 

 

 

Contessa 

Freestanding Woodburner 

 

 

 

 

Firenzo Woodfires UK Limited 

98 Niven Street, Napier 4142, New Zealand 

Website: www.firenzo.co.uk 

 
 

Содержание CONTESSA

Страница 1: ...1 CI 2013 05 14 Instructions for Installation Contessa Freestanding Woodburner Firenzo Woodfires UK Limited 98 Niven Street Napier 4142 New Zealand Website www firenzo co uk ...

Страница 2: ...s 3 3 1 Draught 3 3 2 The draught will be reduced when 3 3 3 A good draught is achieved when 4 Chimney sweep 5 Stove placement clearance and floor protector requirements 5 1 Floor protector requirements 5 2 On the floor 5 3 Clearance to furniture and soft furnishings 6 HETAS amendments 6 1 More detailed advice about existing chimney usage 6 2 Commissioning and handover 6 3 Extractor fan 6 4 Perman...

Страница 3: ...t 2 5 Metal parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury 2 6 Note of references to the current UK regulations In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Re...

Страница 4: ... and up to 50kW rated output burning any fuel 175mm diameter or rectangular square flues having the same cross sectional area and a minimum dimension not less than 150mm NOTES 1 Closed appliances include cookers stoves room heaters and boilers 2 Fuels such as bituminous coal untreated wood or compressed paper are not smokeless or low volatiles fuels 3 These appliances are known as exempted firepla...

Страница 5: ...The chimney is not tall enough with the result that it sits in the lee of the roof surface or tall trees These conditions are also associated with the greatest risk of smoke coming back down the chimney Air is entering the chimney in undesired places e g through cracked joints or leaks in the cleaning door or the flue pipe Unsealed unused fireplaces are connected to the chimney The flue pipe and c...

Страница 6: ... of 700 mm When lit a wood burning stove gets hot and therefore adequate protect must be provided particularly in situations where there is a safety risk to children or the infirm A suitable safety guard around the stove should be considered 6 HETAS amendments 6 1 More detailed advice about existing chimney usage NOTE A chimney height of not less than 4 5 metres measured vertically from the outlet...

Страница 7: ... to do should smoke or fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons 6 3 Extractor fan There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit smoke and fumes into the room 6 4 Permanent air vent The stove requires a permanen...

Страница 8: ...ent of the flue system to the spigot outlet 6 Assemble and install flue system accordingly to comply with all national and local regulations 7 Fit the air control knob place the flat on the knob to the flat on the shaft situated on the right hand side of the fire Press home firmly 8 Fit door knob with spacer as per drawing shown below 9 Commission stove to ensure correct operation and adequate flu...

Отзывы: