background image

Kompact AG Installation—November 2018                                                                                                                                                    43

 

 

   

 

10

 

For  information  (including  claim  procedures)  concerning  potential  claims,  potential         

warranty claimants should contact: 

 

          

-

 in the first instance, the retailer/dealer from whom the Firenzo wood fire was  originally          

purchased or 

 

-

 (if the retailer/dealer is not contactable or does not address the claim to the claimant

satisfaction) Firenzo at the specified address, 

 

including as appropriate to arrange an inspection of the Firenzo wood fire.

 

11

 

After  complying  with  paragraph  10,  for  valid  claims,  a  warranty  claimant  must  submit  a 

comple ted warranty claim form (please see Firenzo

s website, or contact Firenzo, for this form) 

or  other  form  acceptable  to  Firenzo  providing  details  of  the  consumer

s  warranty  from  the      

Warranty Registration Card (including its date of issue) and specifying the defect: 

 

-

 to the retailer/dealer from whom the Firenzo wood fire was originally purchased; or

 

-

 to Firenzo at the specified address.

 

12

 

The  warranty  claimant  is  responsible  for  paying  any  service  call  fees,  transport  charges 

and for any damages and loss incurred in transit to the Firenzo wood fire or its component parts 

and materials, to and from Firenzo or its designated accredited agent. Where Firenzo honours a 

warranty,  as    described  in  paragraph  13,  it  will  reimburse  the  warranty  claimant  any                      

transportation costs they have incurred.

 

13

 

Firenzo  or  its  designated  accredited  agent  (please  see  paragraph  16)  will  replace  any   

component parts and materials covered by the warranties or the entire Firenzo wood fire, at its 

discretion,  where  Firenzo  is  reasonably  satisfied  a  defect  is  solely  due  to  faulty  Firenzo          

workmanship or materials.

 

14

 

Firenzo may decline (in whole or part) to honour a warranty claim:     

 

-

 until any amounts due but unpaid by a consumer in respect of the Firenzo wood fire or 

its     servicing are paid.

 

-

 until Firenzo is provided with the applicable compliance and installation permits (please 

see below);

 

-

 if it appears to Firenzo that the Firenzo wood fire has:

 

-

 not been installed correctly at the specified residential address, or not been  

 

 operated  and  maintained  strictly  in  accordance  with  the  manufacturer

s            

instructions, AS/NZS 2918:2001 and any relevant building code or consent or 

these warranty terms.

 

not  been  inspected  and  confirmed  after  installation  as  a  compliant  installation 

(with the requisite specifications and permits);

 

not been regularly maintained and at least annually serviced;

 

-

 been subject to misuse, neglect, or accident in transit, storage or use.

 

-

  been  damaged  by  water  ingress  in  any  way,  including  any  surface  rust  which 

has     occurred in transit or storage. However this exclusion will not apply to 

any  damage  to  the  Firenzo  wood  fire  which  is  determined  to  have  been 

caused by wetback leakage attributable to faulty Firenzo component parts or 

materials or workmanship;.

-

 been over fired or has used any fuel other than 

clean  dry  firewood  (having  25%  or  less  moisture  content),  including  any  

chemically treated timbers or driftwood. 

 

-

 if it appears to Firenzo that the defect is attributable to a failure to replace  consumable 

parts or components or materials within a timely manner to maintain their durability. 

 

 

Содержание Kompact AG Series

Страница 1: ...ome Heating Association solid fuel appliance installation technician SFAIT or other suitably qualified person The Fire and Flue System must be installed in accordance with AS NZS2918 All Installations must be in accordance with these instructions Consult with the building authority having jurisdiction to determine the need for a permit prior to commencing the installation Failure to follow these i...

Страница 2: ... Requirements 24 11 Mantel Clearances 25 12 Installation of Kaowool ISB Insulation in a Built in Canopy 26 13 Assembly Instructions Zero Clearance Box Built In Fire Canopy 27 28 14 KOMPACT with ATHENA Fascia 29 30 KOMPACT with DECO Fascia 31 32 KOMPACT with DIVA Fascia 33 34 KOMPACT with FORTE Fascia 35 37 KOMPACT with PLAZA 780mm 1000mm Fascia 38 15 Operating Instructions 39 Operating Instruction...

Страница 3: ...DS or AEROSOLS in the vicinity of this FIRE when it is operating Use caution when reloading with fuel Do NOT attempt to load fuel into the Fire when the fire inside the stove is at or near its peak Do NOT burn large quantities of paper or combustible material that would create an extremely hot quick fire Do NOT burn highly coloured paper or brochures junk mail USE ONLY DRY WOOD 25 or less moisture...

Страница 4: ...adherence to these instructions will meet these standards Any variation from these installation instructions or any doubt about them must be checked against the requirements of the standards Please leave this manual with the owner when installation is complete KOMPACT ZERO CLEARANCE BOX IN A MASONRY FIREPLACE OR ENCLOSURE 3 FLOOR PROTECTION REQUIREMENTS AS NZ2918 Section 3 3 states that if the Fir...

Страница 5: ... has no heat sensitive materials in its construction it must meet the following MINIMIUM dimension as marked A B from above A 300mm from breast of fire to outer edge of concrete floor protector hearth B 30mm from heat sensitive floor to upper edge of concrete floor protector hearth The minimum width of floor protector must be 820mm and or 410mm from the centre of the Fire ...

Страница 6: ... Ensure any cracks are sealed loose masonry repaired and the chimney swept Check the dimensions of your fireplace opening are adequate to accept the new Fire Existing linings may need to be removed The Fire must be installed on a level non combustible base An Insulated Floor Protector Hearth must consist of a minimum of 20mm of Insulation board Promatech H Eterpan LD Pacbld Pro or product of simil...

Страница 7: ...is may be reduced if a Firenzo Kompact deflector is fitted A Unprotected B With Firenzo Deflector Kompact Diva 975mm N A Kompact Forte 975mm 915mm Kompact Athena 1100mm 915mm Kompact Deco 1225mm 915mm Kompact Plaza 1225mm 915mm SIDE PILLAR CLEARANCE The minimum clearance from the side of the fascia to any heat sensitive material must be 5mm providing the material does NOT protrude more than 150mm ...

Страница 8: ... firebox and flue are in position place 25mm white Kaowool blanket supplied on top of casing 7 As this fire sources its combustion air from the chimney cavity enclosure the Fire MUST be sealed around the front between the casing and the masonry This is achieved by packing the yellow ISB insulation supplied between the casing and the masonry at the FRONT ONLY to maximum depth of 80mm As shown on pa...

Страница 9: ...Kompact AG Installation November 2018 9 6 TYPICAL INSULATION REQUIREMENTS ...

Страница 10: ...om the chimney cavity the fire must be sealed using the yellow ISB insulation provided around the front of the casing and masonry enclosure at the FRONT ONLY to a maximum depth of 80mm UNDER NO CIRCUMSTANCES SHOULD THE AIR SUPPLY INTO THE AIRPORTS ON THE SIDE OF THE FIRE BE RESTRICTED ...

Страница 11: ...top The chimney plate must be weather sealed with silicone or mortar 4 Install chimney liner on top of the chimney plate 5 Ensure flue is extended over the chimney liner by 180mm Secure top spacer bracket to the flue and ensure slots fit snugly inside the chimney liner 6 Slide flashing cone over top of flue until it rests firmly over top spacer Ensure ventilation gap is not closed off Secure with ...

Страница 12: ...Kompact AG Installation November 2018 12 8 INSERT FLUE SYSTEM FOR INSTALLATION IN A ZERO CLEARANCE BOX FIREPLACE ...

Страница 13: ...op of the floor protector 2 The flue cowl must be at least 600mm above the highest point of the roof if within 3 metres of it or 1 metre above the roof penetration if more than 3 metres from the ridge 3 No part of the building or any adjacent building may be in or above a circular area of a horizontal radius of 3 metres from the flue exit ...

Страница 14: ...O CLEARANCE BOX BUILT IN FIRE CANOPY A ZERO CLEARANCE BOX Built in Fire Canopy IS REQUIRED IF THE FIRE IS NOT BEING INSTALLED INTO A MASONRY FIREPLACE For Zero Clearance Box installations see the following pages 15 to 22 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 15: ...Kompact AG Installation November 2018 15 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 16: ...Kompact AG Installation November 2018 16 DIMENSIONS IN MILLIMETERS UNLESS OTHERWISE STATED STANDARD FRAME ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 17: ...Kompact AG Installation November 2018 17 Dimensions taken from Zero Clear ance Box ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 18: ...Kompact AG Installation November 2018 18 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 19: ...Kompact AG Installation November 2018 19 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 20: ...Kompact AG Installation November 2018 20 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 21: ...Kompact AG Installation November 2018 21 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 22: ...Kompact AG Installation November 2018 22 ZERO CLEARANCE BOX Built in Fire Canopy ...

Страница 23: ...Kompact AG Installation November 2018 23 10 FLOOR PROTECTOR REQUIREMENTS FOR A ZERO CLEARANCE BOX BUILT IN CANOPY FIRE WITH HEAT SENSITIVE FLOOR Fire ...

Страница 24: ...200mm deep A Unprotected not tested with deflector Kompact Athena 1180mm B With Firenzo Deflector Only Kompact Deco 1180mm Kompact Diva 1180mm minimum Kompact Forte 1180mm minimum Kompact Plaza 1180mm Kompact Serenity 1180mm Non heat sensitive non combustible mantle no greater than 200mm deep A Unprotected deflector not required All Kompact fires 1180mm SIDE PILLAR CLEARANCE The minimum clearance ...

Страница 25: ...Kompact AG Installation November 2018 25 12 INSTALLATION OF KAOWOOL AND ISB INSULATION IN A ZERO CLEARANCE BOX ...

Страница 26: ...as per instructions on pages 11 13 if using a Zero Clearance Box Built in Fire Canopy 6 As this Fire sources its combustion air from the chimney cavity enclosure the Fire MUST be sealed around the front between the casing and Zero Clearance Box This is achieved by packing the yellow ISB insulation supplied between the casing and the built in canopy at the FRONT ONLY to maximum depth of 80mm UNDER ...

Страница 27: ...Kompact AG Installation November 2018 27 14 KOMPACT WITH ATHENA FASCIA ...

Страница 28: ... granite ashlip from the fascia box and fit below the door opening using the two locator screws at the bottom of the firebox screws for granite ashlip 5 see illustration 1 These two screws protrude by 5mm to enable the ashlip to be lifted up and over the screw heads and then screw up tight 4 4 4 3 5 3 Athena Ashlip 4 Fit the bottom grill on to the 2 locating screws Bottom Grill 3 4 6 5 Fit the top...

Страница 29: ...Kompact AG Installation November 2018 29 KOMPACT WITH DECO FASCIA ...

Страница 30: ...opening using the two locator screws at the bottom of the firebox Screws for granite ashlip 3 see illustration 1 These two screws protrude by 5mm to enable the ashlip to be lifted up and over the screw heads and then screw up tight Attach the bottom grill 2 Granite ashlip 5 Bottom grill 5 3 4 Place the keyhole brackets on the 3 plate Deco fascia over the protruding screws on the back plate Screws ...

Страница 31: ...Kompact AG Installation November 2018 31 Assembly and Installation Instructions KOMPACT with DIVA Fascia ...

Страница 32: ... 15mm self tap screw below the door opening 6 4 Fit the air control knob 7 Fit the granite ashlip 8 provided by securing it to the bottom support plate by inserting the locking pin on the support plate into the hole on the bottom of the granite ashlip Finally fit the door Locate the hinges correctly by angling the door at approximately 45 degrees 2 3 4 1 Remove door Place the backplate with bottom...

Страница 33: ...Kompact AG Installation November 2018 33 KOMPACT WITH FORTE FASCIA ...

Страница 34: ...Kompact AG Installation November 2018 34 Assembly and Installation Instructions KOMPACT with FORTE Fascia ...

Страница 35: ...Kompact AG Installation November 2018 35 KOMPACT WITH 780MM PLAZA FASCIA 780mm Fascia Masonry ONLY ...

Страница 36: ...Kompact AG Installation November 2018 36 KOMPACT WITH 1000MM PLAZA FASCIA 1000mm Fascia Masonry and Zero Clearance ...

Страница 37: ...Kompact AG Installation November 2018 37 Assembly and Installation Instructions KOMPACT with PLAZA Fascia ...

Страница 38: ...n door carefully and place small pieces then larger logs on top 6 Close door tight and leave Air Control on HIGH for some 30 minutes The value in establishing this technique is that you are providing an excellent base for burning your wood effectively 7 When a good fire is established move air control to middle position DO NOT IMMEDIATELY SHUT THE FIRE TO LOW Remember to close the air con trol gra...

Страница 39: ...almost empty Fire set at the same position Remember you only get out of any Fire what you put into it The better the fuel the better the Fire Do NOT burn plastic household refuse or driftwood This will void any Warranty and reduce the lifespan of the fire FLAMMABLE LIQUIDS CAUTION Never use gasoline type fuel kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in this F...

Страница 40: ...urer s instructions for spraying Never spray a hot fire BLACK OR SILVER PLATED RAILS The black or silver plated rails must not come in contact with abrasive materials Use a clean damp cloth when the Fire is cool if cleaning is required FIRE BRICKS The internal fire bricks on the sides and base of the firebox can crack in extreme heat However they are safe to leave as is until they start to crumble...

Страница 41: ...ting material for the glass should be replaced at this time also NEVER place glass directly against the door Without the insulation seal tape in place the glass is likely to shatter Your Firenzo agent will be able to supply any spare parts 18 SAFETY All surfaces on the inserts will get hot and cause burning if touched by bare hands Firenzo recommends using a fireguard The heat from inserts will ef...

Страница 42: ...Guarantees Act 1993 To the fullest extent permitted at law no other warranties or guarantees express or implied are assumed or given by Firenzo to any person with respect to the quality merchantability description or fitness for purpose or use of Firenzo wood fires or their component parts and materials 6 Firenzo is not liable for and to the maximum extent permitted by law excludes any liability f...

Страница 43: ...covered by the warranties or the entire Firenzo wood fire at its discretion where Firenzo is reasonably satisfied a defect is solely due to faulty Firenzo workmanship or materials 14 Firenzo may decline in whole or part to honour a warranty claim until any amounts due but unpaid by a consumer in respect of the Firenzo wood fire or its servicing are paid until Firenzo is provided with the applicabl...

Страница 44: ... questions about the warranties or this document please contact Firenzo at its specified address on telephone 06 8438260 by email at firenzo firenzo co nz or via the Firenzo website www firenzo co nz 18 This document is intended to form part of and may be expressly referenced in the terms of sale and purchase by every original New Zealand consumer of a Firenzo wood fire Without limiting that inten...

Страница 45: ...Kompact AG Installation November 2018 45 ...

Страница 46: ... Encore Lady Kitchener Napier Viking Vision Insert Aqualux Athena Bay Flush Forte Bay Flush Kompact Athena Kompact Deco Kompact Diva Kompact Forte Kompact Plaza Kompact Serenity Topaz 98 Niven Street PO Box 3231 HB Mail Centre Napier 4142 Phone 06 8438260 Website www firenzo co nz email firenzo firenzo co nz ...

Отзывы: