Dimensions are given in mm.

Building In

Building over a cupboard or
drawer

If the hob is to be installed above a cupboard or drawer
it will be necessary to fit a heat resistant board below
the base of the hob on the underside of the work
surface.
It is also recommended to carry out the electrical
connection to the hob as shown in diagrams 1 and 2.

Building over a kitchen unit
with door

Proper arrangements must be taken in designing the
furniture unit, in order to avoid any contact with the
bottom of the hob which can be heated when it is
operated. The recommended solution is shown in
diagram 3.
The panel fitted under the hob  ("a") should be easily
removable to allow easy access if technical
assistance is needed. The space behind the kitchen
unit ("b") can be used for connections.

Rectangular cut-out size for hob

A)

End of shaft with nut

B)

Washer

C)

Elbow

It is important to install the elbow correctly, with
the shoulder on the end of the thread, fitted to the
hob connecting pipe.
Failure to ensure the correct assembly will cause
leakage of gas.

FO 0814

Gas Connection

Connection to the gas supply should be with either rigid
or semi-rigid pipe, i.e. steel or copper.
The connection should be suitable for connecting to R 1/
2" (1/2 BSP male thread).
When the final connection has been made, it is essential
that a thorough leak test is carried out on the hob and
installation.
Ensure that the main connection pipe does not exert
any strain on the hob.

FO 2098

Dimensions are given in mm.

FO 0264

Cut Out Size

The dimensions of the cut-out are given in the diagram.

30

20 min

60

a

b

FO 1013

3

550

470

30

Содержание FGH 610

Страница 1: ...GAS HOB FGH 610 INSTRUCTION BOOKLET 35685 3401 GB...

Страница 2: ...2...

Страница 3: ...is intended for domestic cooking only It is not designed for commercial or industrial purposes z When in use a gas cooking appliance will produce heat and moisture in the room in which it has been ins...

Страница 4: ...6 Service and Spare Parts 6 Guarantee Conditions 7 Engineers technical data 8 Installation 9 Building In 10 Electrical connections 11 Wiring Diagram 12 Fault Finding 12 Commissioning 14 Conversion fro...

Страница 5: ...lectricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool The Hob Top Regularlywipeoverthehobtopusingasoftclothwellwrung out i...

Страница 6: ...l make a charge if the fault is not a mechanical or electrical breakdown Service and Spare Parts In the event of your appliance requiring service or if you wish to purchase spare parts please contact...

Страница 7: ...bulbs or removable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom Appliances found to be in...

Страница 8: ...V 0 6 YA T 120 Spark Gap Fixed Rear Left Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Left Burner rapid Heat Input 3 0 kW 10236 BTU HR Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid...

Страница 9: ...r vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before making the cut out in the worktop ensure that the edges...

Страница 10: ...to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is...

Страница 11: ...to the cable a 3 amp plug provided withASTAapproved BS 1362 fuse must be used The wires in the mains lead are coloured in accordance with the following code Green andYellow Earth Blue Neutral Brown Li...

Страница 12: ...an infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trac...

Страница 13: ...ight burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignitio...

Страница 14: ...gnite the burner and set to MIN Remove the control knob To adjust use a thin bladed screwdriver and turn the adjustment screw see diagram until the flame is steady and does not extinguish when the kno...

Страница 15: ...ly Remove all pan supports burner caps rings crowns and control knobs With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors TO ADJU...