10
Purevision Freestanding
Issue 02 01/14
6.0
Technical Data & Declaration of Performance (DoP)
Manufacturer:
Fireline UK Ltd, a Division of Charlton & Jenrick Ltd.
Range Designation:
Purevision freestanding stoves.
Models:
Purevision 5kW, 5kW Wide and 8.5kW with nominal outputs of 5kW, 5kW and 8.5kW.
Intended Use:
Domestic heating appliances
Independently Performance & Safety tested by:
Kiwa Gastec, Notified Body No: 0558
Constancy of Performance System:
ISO9001
Signed:
Peter Mintoft
Director
October 2013
NOTE:
Refuelling intervals for testing are chosen according to the standards concerned for performance testing
and are comparative only. They
do not
relate directly to re-fuelling intervals that can be achieved on an installed
product. Re-fuelling intervals of 1-1.5h for wood and 3-4+ hours for Ancit would be more usual. Under normal
conditions on a low air control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Model
Purevision
5kW
Purevision
5kW Wide
Purevision
8.5kW
Notes
Appliance weight (packed/unpacked) (Kg):
105/94
120/108
153/139
Approximate Output Range: (kW)
3.1 - 6
3.8 - 8
4.9-10
Harmonised EN European Standard (hEN):
EN13240:
2001 Amd 2:
2004
EN13240:
2001 Amd 2:
2004
EN13240:
2001 Amd 2:
2004
Additional Characteristics Test Standard:
DIN +
DIN +
DIN +
Additional Particulate Emission Test Standard:
PD6434
PD6434
PD6434
Performance Characteristics on Wood Fuel
Test Report Issue Date:
10/2013
10/2013
10/2013
Total Efficiency: (%)
80.2
82.2
76.7
Declared nominal output: (kW)
5
5
8.5
Tested nominal Output: (kW)
4.9
5
8.4
Tested wood re-fuelling interval: (h)
0.75
0.76
0.75
Flue gas mass flow: (g/s)
3.6
3.6
5.9
Mean CO emission (@13% O
2
) : (%)
(Nmg/m
3
)
0.1
(1250)
0.08
(1000)
0.1
(1250)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
96
61
76
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
124
128
96
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
17
10
19
PD6434 Particulate Emissions High output: (gh
-1
)
2.5
3.2
3.7
PD6434 Particulate Emissions Low output: (gh
-1
)
1.5
1.5
1.7
Optical Density Time > 0.2 High (Mins)
1.2
0.2
0.4
Optical Density Time > 0.2 Low (Mins)
0.7
0.4
1.4
*Mean Flue Temperature: (Deg C)
301
274
363
Approximate Max Log Length: (mm)
300
400
400 - 650
Performance Characteristics on Ancit Briquetted Smokeless Fuel
Total Efficiency: (%):
74.8
80.0
77.4
Declared nominal output: (kW)
5.0
5.0
8.5
Tested nominal output: (kW)
5.0
5.0
8.7
Tested re-fuelling interval: (h)
1.01
1.07
1.03
Flue gas mass flow: (g/s)
3.7
2.7
6.1
Mean CO emission (@13% O
2
) : (%)
(Nmg/m
3
)
0.16
(2000)
0.51
(6375)
0.07
(875)
Mean Flue Temperature: (Deg C)
239
174
339
Safety Distances From Combustibles
Side Wall: (mm)
400
250
150
Rear Wall: (mm)
600
450
400