8
FGi.FPi.FXi
Issue
12 10/17
5.0
Technical Data & Declaration of Performance (DoP)
Manufacturer: Charlton & Jenrick Ltd.
Range Designation: FG/FX/FP Eco Inset Stoves.
Models: FG/FX/FPi5, FG/FX/FPi5W, FG/FX/FPi8 Eco with nominal outputs of 5kW, 5kW and 8kW.
Intended Use: Domestic heating appliances
Independently Performance & Safety tested by: Kiwa Gastec, Notified Body No: 0558
Constancy of Performance System: ISO9001
Signed:
Peter Mintoft
Director
November 2017
NOTE: Refuelling intervals for testing are chosen according to the standards concerned for performance testing and are
comparative only. They do not relate directly to re-fuelling intervals that can/might/will be achieved on an installed product. Re-
fuelling intervals of 1-1.5h for wood and 3-4+ hours for briquetted smokeless fuels would be more usual. Under normal
conditions on a low air control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Model
FG/FX/FPi5
FG/FX/FPi5W
FG/FX/FPi8
Notes
Appliance weight (packed/unpacked) (Kg):
80/70
95/84
118/105
Approximate Output Range: (kW)
4.0-6.0
4.3-6.5
5.5-11.0
Harmonised EN European Standard (hEN):
EN13229: 2001
Amd 2: 2004
EN13229: 2001
Amd 2: 2004
EN13229: 2001
Amd 2: 2004
Additional Characteristics Test Standard:
DIN +
DIN +
DIN +
Additional Particulate Emission Test Standard:
PD6434
PD6434
PD6434
Performance Characteristics using Wood Fuel
Test Report Issue Date:
11/17
11/17
11/17
Total Efficiency: (%)
81.0
78.0
78.4
Declared nominal output: (kW)
5.0
5.0
8.0
Tested nominal Output: (kW)
5.0
5.0
7.9
Tested wood re-fuelling interval: (h)
0.82
0.8
0.78
Flue gas mass flow: (g/s)
3.6
4.4
5.8
Mean CO emission (@13% O
2
) : (%) (Nmg/m
3
)
0.06 (750)
0.07 (875)
0.05 (625)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
24
35
27
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
84
83
83
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
11
15
15
PD6434 Particulate Emissions High output: (gh
-1
)
2.0
3.5
2.6
PD6434 Particulate Emissions Low output: (gh
-1
)
1.8
1.6
1.6
Optical Density Time > 0.2 High (Mins)
0.6
1.2
1.1
Optical Density Time > 0.2 Low (Mins)
0.6
0.0
0.8
Mean Flue Temperature: (Deg C)
288
292
331
Nominal
EEI Labelling Category
A+
A
A
Approximate Max Log Length: (mm)
300
395
540
Performance Characteristics using Ancit Briquetted Smokeless Fuel
Test Report Issue Date:
10/2014
10/2014
10/2014
Total Efficiency: (%):
76.4
76.5
77.0
Declared nominal output: (kW)
5
5
8
Tested nominal output: (kW)
5.2
5.2
8.5
Tested re-fuelling interval: (h)
1.05
1.02
0.97
Flue gas mass flow: (g/s)
3.8
4.2
5.9
Mean CO emission (@13% O
2
) : (%) (Nmg/m
3
)
0.09 (1125)
0.09 (1125)
0.07 (875)
Mean C
n
H
m
emission (@13% O
2
): (Nmg/m
3
)
33
12
19
Mean NOx emission (@13% O
2
): (Nmg/m
3
)
91
144
115
DIN+ particulates (@13% O
2
): (Nmg/m
3
)
33
35
40
Mean Flue Temperature: (Deg C)
275
253
297
Nominal
Safety Distances From Combustibles
Shelf: (mm)
250
400
400
Side Full Combustible Wall
350
350
350
Side Surround Leg: (mm)
150
150
150