Firelight Blaze Скачать руководство пользователя страница 4

DMX Mode Selection  

 
The FL-B Blaze fixture has internal jumpers which can be preset to operate the unit in one of four  DMX 
control modes.  Minimal control mode allows control of fixture intensity, while full control mode allows control 
over fixture intensity and effect motor speed.  Depending on the fixture model, the unit may be set to use 
from one to four DMX channels.  The default setting for all FL-B Blaze fixtures is for four channel DMX 
mode.  The first two channels control the intensity of the red and amber LED emitters, with two additional 
channels controlling the speed of the effect drive motors.       
 

 
DMX Mode Confirmation 

 

The selected DMX mode can be confirmed without opening the unit.  When power is applied to the fixture in 
DMX mode, the green “Power” indicator will light immediately, and the green “Sync” indicator will flash from 
one to four times depending upon the DMX Mode setting.  The number of flashes corresponds to the mode, 
and to the number of DMX channels required to properly control the fixture.  After displaying the DMX 
mode, the “Sync” indicator will then go out in the absence of DMX data, or will illuminate steadily if good 
DMX data is being received.  

 

 

 
DMX Mode Selection 

 
The DMX mode is selected by the position of internal jumpers J7 and J8, which are located on the DMX 
Interface board inside the fixture.  If necessary, these settings can be altered by opening the fixture to change 
the jumper settings . The fixture should be disconnected from the DC power supply before opening the unit 
housing to change any jumper setting.  The jumper positions for the various settings are illustrated below.    

 

 

 
 
 
 
 
 
 
 
 
 
 
DMX Channel Assignments 

 
The DMX channel assignments in the four available modes are defined in the following chart 
 
Mode 

Channel 1 

Channel 2 

Channel 3 

Channel 4 

One Channel 

LED Intensity* 

Unused 

Unused 

Unused 

Two Channels 

LED 1 Intensity 

LED 2 Intensity 

Unused 

Unused 

Three Channels 

LED Intensity* 

Motor 1 Speed 

Motor 2 Speed 

Unused 

Four Channels 

LED 1 Intensity 

LED 2 Intensity 

Motor 1 Speed 

Motor 2 Speed 

 
*  LED intensity in these settings will control the output of both LED driver channels, which are commonly 
driven in parallel for driving high output white LED emitters, or arrays of multiple emitters.   

Содержание Blaze

Страница 1: ...rovides control of effect motor speed and output intensity Installation of glass or dichroic color filters aperture plates or other optics in the filter slot provided will create further variations in the appearance of the output pattern Recommended Use The Firelight Blaze fixture is intended for use in applications where the appearance or illusion of fire or flames is desired The fixture is inten...

Страница 2: ...ture which is not covered by the fixture warranty and may cause increased risk of electrical shock or fire potentially resulting in serious injury or death The Firelight FL B models are usually shipped with a Universal Voltage AC power supply which can operate the fixture from 100 to 240 volt AC line voltage at either 50 or 60 Hertz Do not attempt to operate the unit or power supply from unknown o...

Страница 3: ...selected External Manual Mode Selection and Operation When no DMX data source is available the FL B Blaze fixture can be set to operate in manual mode for either demonstration purposes or for stand alone operation Manual mode can be selected by setting the DMX address switches to address 900 or higher When the unit is powered up with a DMX address setting of 900 or above normally invalid the fixtu...

Страница 4: ...xture After displaying the DMX mode the Sync indicator will then go out in the absence of DMX data or will illuminate steadily if good DMX data is being received DMX Mode Selection The DMX mode is selected by the position of internal jumpers J7 and J8 which are located on the DMX Interface board inside the fixture If necessary these settings can be altered by opening the fixture to change the jump...

Страница 5: ...s and effect motors will operate at the intensity and speed settings as determined by the DMX data values The unit will continue to operate in this manner until the settings are readjusted to the users preference The fixture is rated for continuous operation and in normal use the unit will continue to display the desired output pattern until power is removed or until the DMX data settings are alte...

Страница 6: ...cts are generated The remaining control mode is the Analog Mode where the LED emitter is always active but the LED drive current is modulated to control the emitter intensity In this mode there is no PWM modulation of the LED output which will appear constant to the eye and also on high speed film or video systems All control modes feature a positive LED shutoff at minimum intensity settings The d...

Страница 7: ...er is responsible for mounting the instrument in a safe and secure manner Please consult with local public or workplace safety authorities to determine if any additional safety restraints such as safety wires or cables may be required Aiming The instrument can be pointed using the mounting hole on the yoke as a directional pivot Tightening the mounting fastener will lock the instrument in that axi...

Страница 8: ... two inches by two inches or 50mm square in size and be no thicker than 1 16 inch or 1 5mm A thumbscrew at the front of the unit retains the filter Both color filters and shaped apertures may be used to change the general character and appearance of the projected display To install or change a filter disconnect power to the unit remove the thumbscrew next to the output port and slide the filter in...

Страница 9: ...om 5 to 7 turns from minimum Higher or lower settings may be used depending upon the display requirements It is normal for the noise level from the effect motors to increase at higher speed settings but the motors will not be damaged by prolonged operation even at maximum speed settings Motor speed controls are non functional in 3 or 4 channel DMX mode Changing Motor Direction Two switches control...

Страница 10: ...ust through the optical section of the fixture Dust will eventually build up outside and inside the fixture over time Heavy accumulations of dust will reduce the fixture output and may reduce the airflow through the unit resulting in increased temperatures and reduced LED lifetimes Periodic cleaning with compressed air or bottled gas will remove most light dust contamination Heavy dust contaminati...

Страница 11: ... drivers LED Emitters operate normally Motor speed settings at minimum 1 2 Ch Manual Mode but no effect motion or animation Motor direction switches set at mid position Defective effect motor or motor driver Fixture partially illuminates the normal Fixture output blocked or occluded display area Manual intensity setting at minimum Manual Mode DMX data for inactive area at minimum 4 Ch Mode Defecti...

Страница 12: ...atts Transformer 100 240 VAC 50 60 Hz UL listed Class 2 power supply Universal input voltage Controls Manual focus and effect direction Manual or DMX speed and intensity DMX 5 pin XLR isolated input and output OPTIONS AND ACCESSORIES Emitters Dual 10 Watt White LED Lumen Maint 25 000 hours at 70 minimum Color Temp 6300 Kelvin Cool White Dispersion 53 degrees typical soft edge Gel Filter 2 x 2 or 5...

Отзывы: