Firelight Blaze Скачать руководство пользователя страница 1

 

 

 

FIRELIGHT BLAZE USER INSTRUCTIONS 

 

Description: 

 
The Firelight  model FL-B “Blaze” fixture is a compact, lightweight  moving pattern projector which uses 
advanced long lifetime LED light sources to produce high light output from a very small package.  The unit is 
designed to project a moving pattern of light with an irregular character resembling the appearance of fire or 
flames.  Two pattern wheels rotated by gear reduction motors produce the moving effect pattern with very 
little light loss.  The projection lens mount allows for adjustment of effect focus.  The lighting industry 
standard DMX control interface provides control of effect motor speed and output intensity.  Installation of 
glass or dichroic color filters, aperture plates, or other optics in the filter slot provided will create further 
variations in the appearance of the output pattern.   
 

 

Recommended Use 

 
The Firelight Blaze fixture is intended for use in applications where the appearance or illusion of fire or flames 
is desired.  The fixture is intended to operate from a 120 volt AC power source using the DC power supply 
provided, or an appropriate substitute.  The FL-B unit can be operated from any DC power source with 
correct voltage and polarity, and an adequate current rating.   
 

 

 

 

PRECISION PROJECTION SYSTEMS INCORPORATED 

17508 STUDEBAKER ROAD, CERRITOS, CA 90703-3638 

TELEPHONE: 562 865-8552 FACSIMILE: 562 924-7133 

WEBSITE 

www.ppsfx.com

 

EMAIL: 

[email protected]

 

Содержание Blaze

Страница 1: ...rovides control of effect motor speed and output intensity Installation of glass or dichroic color filters aperture plates or other optics in the filter slot provided will create further variations in the appearance of the output pattern Recommended Use The Firelight Blaze fixture is intended for use in applications where the appearance or illusion of fire or flames is desired The fixture is inten...

Страница 2: ...ture which is not covered by the fixture warranty and may cause increased risk of electrical shock or fire potentially resulting in serious injury or death The Firelight FL B models are usually shipped with a Universal Voltage AC power supply which can operate the fixture from 100 to 240 volt AC line voltage at either 50 or 60 Hertz Do not attempt to operate the unit or power supply from unknown o...

Страница 3: ...selected External Manual Mode Selection and Operation When no DMX data source is available the FL B Blaze fixture can be set to operate in manual mode for either demonstration purposes or for stand alone operation Manual mode can be selected by setting the DMX address switches to address 900 or higher When the unit is powered up with a DMX address setting of 900 or above normally invalid the fixtu...

Страница 4: ...xture After displaying the DMX mode the Sync indicator will then go out in the absence of DMX data or will illuminate steadily if good DMX data is being received DMX Mode Selection The DMX mode is selected by the position of internal jumpers J7 and J8 which are located on the DMX Interface board inside the fixture If necessary these settings can be altered by opening the fixture to change the jump...

Страница 5: ...s and effect motors will operate at the intensity and speed settings as determined by the DMX data values The unit will continue to operate in this manner until the settings are readjusted to the users preference The fixture is rated for continuous operation and in normal use the unit will continue to display the desired output pattern until power is removed or until the DMX data settings are alte...

Страница 6: ...cts are generated The remaining control mode is the Analog Mode where the LED emitter is always active but the LED drive current is modulated to control the emitter intensity In this mode there is no PWM modulation of the LED output which will appear constant to the eye and also on high speed film or video systems All control modes feature a positive LED shutoff at minimum intensity settings The d...

Страница 7: ...er is responsible for mounting the instrument in a safe and secure manner Please consult with local public or workplace safety authorities to determine if any additional safety restraints such as safety wires or cables may be required Aiming The instrument can be pointed using the mounting hole on the yoke as a directional pivot Tightening the mounting fastener will lock the instrument in that axi...

Страница 8: ... two inches by two inches or 50mm square in size and be no thicker than 1 16 inch or 1 5mm A thumbscrew at the front of the unit retains the filter Both color filters and shaped apertures may be used to change the general character and appearance of the projected display To install or change a filter disconnect power to the unit remove the thumbscrew next to the output port and slide the filter in...

Страница 9: ...om 5 to 7 turns from minimum Higher or lower settings may be used depending upon the display requirements It is normal for the noise level from the effect motors to increase at higher speed settings but the motors will not be damaged by prolonged operation even at maximum speed settings Motor speed controls are non functional in 3 or 4 channel DMX mode Changing Motor Direction Two switches control...

Страница 10: ...ust through the optical section of the fixture Dust will eventually build up outside and inside the fixture over time Heavy accumulations of dust will reduce the fixture output and may reduce the airflow through the unit resulting in increased temperatures and reduced LED lifetimes Periodic cleaning with compressed air or bottled gas will remove most light dust contamination Heavy dust contaminati...

Страница 11: ... drivers LED Emitters operate normally Motor speed settings at minimum 1 2 Ch Manual Mode but no effect motion or animation Motor direction switches set at mid position Defective effect motor or motor driver Fixture partially illuminates the normal Fixture output blocked or occluded display area Manual intensity setting at minimum Manual Mode DMX data for inactive area at minimum 4 Ch Mode Defecti...

Страница 12: ...atts Transformer 100 240 VAC 50 60 Hz UL listed Class 2 power supply Universal input voltage Controls Manual focus and effect direction Manual or DMX speed and intensity DMX 5 pin XLR isolated input and output OPTIONS AND ACCESSORIES Emitters Dual 10 Watt White LED Lumen Maint 25 000 hours at 70 minimum Color Temp 6300 Kelvin Cool White Dispersion 53 degrees typical soft edge Gel Filter 2 x 2 or 5...

Отзывы: