![FireLake 155 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/firelake/155/155_owners-manual_2291775003.webp)
Page 3 of 3
SPECIFICATIONS
Model 'A' Oil Pump Model 'J' Oil Pump
1/4 " FNPT
Inlet Port
1/4 " FNPT
1/8 FNPT
Outlet Port
1/8 " FNPT
40-60 PSI
Pressure Range
20-40 PSI
6 GPH
Max. Flow
18 GPH
3450 RPM
Max Allowable Speed
3450
RPM
1/4
HP
1/4
CW Shaft End
Rotation
CW Shaft End
20” Hg
Max Operating Vacuum
20" Hg
10’ Vertical
Maximum Suggested Lift
10' Vertical
<30’, use 3/4” pipe
Horizontal Suction Piping
<30', use 3/4" pipe
30-90’, use 1” pipe
Horizontal Suction Piping
30-90', use 1" pipe
Maximum Fuel Consumption
Model U.S. Gal./Hr. liters/hr Model U.S. Gal./Hr. liters/hr
155 1.1 4.2 200 1.43 5.41
Model U.S. Gal./Hr. liters/hr
245 1.75 6.62 315 2.25 8.52
235 1.6 6 350 2.5 9.46 500 3.6 13.6
Air Pump
(Burner mounted, fits all but Mdl 350, 500)
3450 rpm, filtered inlet, 20 psi discharge.
Minimum Heater Clearances
Above: 6"(15cm)
Inlet Blower: 18"(46cm)
Rear: 18"(46cm)
Chimney Connector: 18"(46cm)
Below: 18"(46cm)
Outlet Louver: 84"(2.1m)
Front: 24”(61cm)
Cabinet Dimensions (includes stack collars but not blower or burner)
Model
Length Width Height
Weight
Hot Air Outlet
155
66”(1.67m) 22”(56cm) 18”(46cm) 150#(68kg)
15” sq. (38cm)
200
79”(2m) 22”(56cm) 22”(56cm) 167#(76kg)
15” sq. (38cm)
245
82”(2.1m) 26”(66cm) 22”(56cm) 200#(91kg)
18” sq. (46cm)
315
96”(2.5m) 26”(66cm) 22”(56cm) 256#(116kg)
18” sq. (46cm)
235
42”(1.1m) 32”(0.8m) 33”(84cm) 350#(160kg) 23x29”(58x74cm)
350
55”(1.4m) 52”(1.32m) 33”(84cm) 800#(364kg) 23x29”(58x74cm)
500
55”(1.4m) 52”(1.32m) 33”(84cm) 800#(364kg) 23x41”(58x104cm)
Overall Dimensions of Heater with Burner and Blower
Model
Length
Width
Height
Weight
155
79.5”(2.0m)
22”(56m)
34.5”(88cm)
234#(106kg)
200
92.5”(2.3m)
22”(56m)
34.5”(88cm)
251#(114kg)
245
95.5”(2.3m)
26”(66m)
41”(1m)
348#(158kg)
315
109.5”(2.8m)
26”(66m)
41”(1m)
348#(158kg)
235
52”(1.3m)
42”(1.1m)
33”(0.84m)
480#(217kg)
350
59”(1.5m)
62”(1.57m)
33”(0.84m)
927#(421kg)
500
59”(1.5m)
62”(1.57m)
33”(0.84m)
927#(421kg)
Construction and Specifications: Certified by UL and filed in MH16601 (US & Canada)
Heat Exchanger :
Stainless and/or aluminized steel. Exhaust collars 8” (20cm), 10” (25.4cm) model 500.
Stack allows connection to either side (except 350,500). Cap provided must be installed on unused collar.
Cabinet :
Mill coated appliance grade painted steel. The louvered opening may be rotated and/or placed
on either side and filler panel is provided and installed on the side opposite the outlet (Except model 350,
500). Burner is attached to a hinged door that allows for easy clean out as well as inspection of nozzle area.
Blower HP (Min.) :
Μ
odel 15, 20, 35: 3/4 HP. Model 24, 31, 50: 1HP
Содержание 155
Страница 21: ...Page 21 of 21 APPLIES TO ALL HEATER MODELS EXCEPT MODEL 500 ...
Страница 23: ...Page 23 of 23 MODEL 500 HEATER ONLY 220 VAC FEED ...
Страница 27: ...Page 27 of 27 K5 Burner w Air Pump 1 of 2 Burner Drawing ...
Страница 28: ...Page 28 of 28 K5 Burner w Air Pump 2 of 2 Burner Drawing ...
Страница 29: ...Page 29 of 29 B5 Burner Drawing ...
Страница 30: ...Page 30 of 30 B5 Burner Drawing ...
Страница 33: ...Page 33 of 33 120 VOLT MODEL B5 TWO STAGE w AIR DELAY BURNER WIRING ...
Страница 34: ...Page 34 of 34 HAS EXTRA AIR SOLENOID AND TIMERS 120 VOLT MODEL B5 TWO STAGE w AIR DELAY BURNER WIRING ...
Страница 55: ...Page 55 of 55 BLUE CABINET MODEL 235 ...
Страница 63: ...Page 63 of 63 BURNERS ...
Страница 65: ...Page 65 of 65 BURNERS CONTINUED ...
Страница 67: ...Page 67 of 67 BURNERS CONTINUED ...