Page 22 of 22
ELECTRICAL CONNECTIONS MODELS 500
Main blower motor(s) are 220 vac. This 220 vac motor power is kept separate from the 120 vac
burner and Fan Control by the Power Relay coil. The Power Relay coil is 120 vac and is activated
by the RED Fan Control wire. Contacts of the Power Relay carry the two 120vac leads to the
220vac motor(s). Note that some dual blower kits may have the Power Relay mounted in the
blower compartment. Slide the large aluminum air filters back to access the components.
[
BOLD
Print is Field Wiring ]
Fan Motor leads to unused terminals on relay
Main power feed panel; (2) 120vac Hot feeds, Neutral, Ground
Power Relay
Burner Cord
Oil Pump Hot to RED Burner wire, Pump Neutral to any WHITE
***Picture is for reference, see following wiring diagrams***
COMPLETING WIRING
3. Connect burner power cord coming from junction box to mating connection on burner. Do
note force, Internal moldings permit only one orientation of connection. Tighten locking
ring to secure.
Run cord through clamp located on top of cabinet, remove slack
from burner cord, clamp and secure. This will prevent burner door from swinging
open and burner capable of firing. Disconnect molded cord to open door and service
burner.
4. Install the room wall thermostat in work area to be heated. Mount it level or accuracy of
settings will be affected. Run 18-2 wire from thermostat to primary control. Connect to
screws labeled T-T on primary control. Set the room thermostat in the “OFF” position.
Содержание 155
Страница 21: ...Page 21 of 21 APPLIES TO ALL HEATER MODELS EXCEPT MODEL 500 ...
Страница 23: ...Page 23 of 23 MODEL 500 HEATER ONLY 220 VAC FEED ...
Страница 27: ...Page 27 of 27 K5 Burner w Air Pump 1 of 2 Burner Drawing ...
Страница 28: ...Page 28 of 28 K5 Burner w Air Pump 2 of 2 Burner Drawing ...
Страница 29: ...Page 29 of 29 B5 Burner Drawing ...
Страница 30: ...Page 30 of 30 B5 Burner Drawing ...
Страница 33: ...Page 33 of 33 120 VOLT MODEL B5 TWO STAGE w AIR DELAY BURNER WIRING ...
Страница 34: ...Page 34 of 34 HAS EXTRA AIR SOLENOID AND TIMERS 120 VOLT MODEL B5 TWO STAGE w AIR DELAY BURNER WIRING ...
Страница 55: ...Page 55 of 55 BLUE CABINET MODEL 235 ...
Страница 63: ...Page 63 of 63 BURNERS ...
Страница 65: ...Page 65 of 65 BURNERS CONTINUED ...
Страница 67: ...Page 67 of 67 BURNERS CONTINUED ...