FireKing NKL Bad Safe Audilok XL Скачать руководство пользователя страница 12

NKL

 auditlok xl

®

®

SERVICE MANUAL

12

®

service nOTes

basic TrOUbLeshOOTing

Lost pin:

 NKL does not have access to any 

PIN  nor  can  a  key  (or  user  number)  be 

made functional without it. If a PIN is lost the 

user must be deleted and reenrolled.

damaged  Key:

  This  may  be  caused  by 

extreme temperature; exposure to electro-

magnetic fields; immersion in liquid. Delete 

any lost or damaged keys.

message

 

ErrOr

,

  iNVALiD    UsEr

:

 

The user is not enrolled, has been deleted, 

or the key is damaged. 

message

 

kEy iNActiVE sEE mAN-

AgEr

:

 The user is inactive. A manager can 

reactivate a user.

display  blank  and  completely  inoperative:

 

Check  power  supply  connections.  Verify 

power  is  present  at  the  AC  outlet.  Verify 

power is present at the DIN connector from 

the transformer. If the power supply is okay 

the problem is the inner board, outer board, 

internal power supply cable, or communi-

cation cable.

display  responds  to  only  some  buttons:

  Re

-

place the outer board.

display  responds  normally  but  there  is  no 

beeping sound when buttons are pressed:

 The 

buzzer is damaged or disconnected. The 

buzzer is located in the cavity behind the 

outer board. The buzzer is connected di

-

rectly to the inner board.

continuous tone with doors closed:

 A door sen-

sor needs adjustment, has failed or become 

disconnected. Log in at the Administrator 

level (New XL) or run an override (New or 

Old  XL)  to  disable  the  offending  sensor 

until  it  can  be  adjusted,  reconnected  or 

replaced.

Unable to enroll a user:

 The user memory is 

full. Delete one or more users. If memory is 

not full and/or deleting users does not solve 

the problem, run an override to clear the 

user table or replace the inner board.

Keyport does not respond:

 Replace the outer 

board.

erratic behavior or corrupt settings:

 Replace 

the inner board.

majOr hisTOricaL changes

power  supply  (Old  XL):

  In  January  2000 

NKL switched from a 9V transformer to a 

12V transformer. Transformers are not in-

terchangeable due to different connectors 

and internal cables. Units with the 9V trans-

former were built with an 8V backup battery 

mounted behind the inner board. The bat-

tery backup feature is no longer supported. 

An  external  UPS  is  recommended  for  all 

installations, past or present.

power supply (new XL):

 AuditLok XL requires 

less power than AuditLok XLV, however you 

may use the AuditLok XLV transformer (part 

15000346) if you have one available and do 

not have the normal 12V transformer.

gold  display  (Old  XL):

  A  gold  outer  board 

was used 2001-2003. If a gold outer board 

fails it should be replaced with a blue outer 

board (15020200).

Keyless  Option  (Old  XL):

  Software  became 

available  to  support  keyless  access, 

streaming  audit  output  and  optional  bio-

metrics reader in 2005.

door sensors:

 Starting in late 2003 to early 

2004 NKL stopped using the switch sensor 

mounted behind the door closer and began 

using the white magnetic plunger sensor 

mounted at the top hinge side of the outer 

door. At the same time the same plunger 

began being used on the inner door.

dust covers:

 In January 2004 the dust covers 

were  changed  for  improved  quality.  New 

dust covers cannot be retrofitted onto old 

safes.

cam mounting:

 In January 2000 NKL began 

using washers with a cotter pin to mount 

the center cam. Prior to this the cam was 

mounted with a capture nut.

Содержание NKL Bad Safe Audilok XL

Страница 1: ...ics NKL is a member of FireKing Security Group 101 Security Parkway New Albany IN 47150 USA Ph 800 528 9900 or 812 948 8400 www fireking com 2008 FireKing Security Group NKL FireKing and AuditLok are registered trademarks of FireKing Security Group Doc 801793 Rev 12 2008 SERVICE Manual ...

Страница 2: ...tronics User features remain substantially similar even though the new AuditLok XL uses completely different circuit boards and cables New AuditLok XL electronics allow either Key or Keyless access Upgrade Policy As of this writing it is NKL policy to replace old AuditLok XL pre 2008 components with the same generation parts until those parts are no longer available When old AuditLok XL parts are ...

Страница 3: ...s after confirmation by a second user Permission Levels Four permission levels exist in the new Au ditLok XL Administrator can configure all safe settings except Company Code this setting may only be set by factory override Manager can open doors and perform limited supervisory actions Users are only permitted to open safe doors Log In Keyless Press any number button except ESC 0 Enter your user n...

Страница 4: ...Level Set PIN Life Set Auto Inactivate Set Auto Delete Set Door Delay Set Time Military Set Date Format Adjust 2 Minutes Set Next Dates Set Delay Access Set Open Time Alarm Select Door to Configure Select Door to Configure Display or Print Enter Personal ID Enter User Name Set Confirm PIN Set Door Permission Enter Old PIN Enter New PIN Confirm New PIN Set Lockout Dates Administrator Menus The foll...

Страница 5: ...able attached E 15054013 Door Sensor Plunger x2 F 15016000 Outer Door Swingbolt Lock G 15011000 Inner Door Springbolt Lock H 15025825 Outer Door Armored Lock Cable I 15025901 Inner Door Armored Lock Cable J 15027003 Data Cable Printer XLiP K 15027001 Power Supply Internal Harness Assembly L 15020613 Alarm Cable M 18000006 Rear connector plate N 700463B RJ45 RJ45 Modular Clip Jack mounted to connec...

Страница 6: ...CROLL BUTTONS NUMBER BUTTONS Key Level Open Safe Door 1 Open Safe Door 2 Open Safe Door 3 Open Safe Door 4 Display or Print Audit Audit Via Modem Adjust DST Enroll Users Delete Users Set Timelocks Set Door Delay Access and Warning Times Armor Car Override Adjust Minutes Arm Disarm Alarm Set Time or Date Set Time or Date Format Print Configuration Initialize Audit Set Idle Text Configure Doors Set ...

Страница 7: ...Lock Cable before 2004 15021826 Outer Door Lock Cable BSD4725 before 2004 G 15011000 Inner Door Lock H 15025901 Inner Door Lock Cable includes 15051013 since 2004 15014000 Inner Door Lock Cable before 2004 no sensor I 15021100 Printer Buzzer Cable J 15021300 Piezoelectric Buzzer K 15020613 Alarm Cable L 15020320 Power Supply Internal Cable Assembly for 12V Transformer 15020300 Power Supply Interna...

Страница 8: ...002 Handle Clevis Pin 5 16 x 7 8 H 06141001 Linkage Clevis Pin x6 3 8 x 3 4 I 06010013 Hex Socket Head Cap Screw x2 10 32 x 3 8 J 10000006 Detent Catch K 10000001 Cam L 06020008 Washer 1 2 ID 2 OD M HW202 Washer 1 2 ID 1 3 8 OD N 06041007 Nylon Handle Bushing 1 2 ID O 10000003 Handle Linkage P 06091006 Nylock Nut 5 8 11 Q 10050141 Vertical Bolt BSD2620 x2 Q 10030141 Vertical Bolt BSD2920 x2 Q 1002...

Страница 9: ...Lock Swingbolt Non handed B 06030022 Screw x3 1 4 20 x 1 1 4 Brass C 700480 Relocker Plate standard right swing 700480L Relocker Plate left swing not shown D 06030007 Screw x2 8 32 x 1 2 E 600 1463 Relocker Pin 3 16 x 1 1 2 F 06500006 Relocker Spring Item Part Description A 800237 Door Closer Rubber Tip B 10000052 Door Closer Tube C 06500005 Door Closer Spring C B A lock harness retainer Item Part...

Страница 10: ...31 700429 Dust Cover BSD4125 10010043 before SP2004004031 700530 Dust Cover BSD4725 10080009 before SP2004004031 700463B Buzzer Bracket 920 5021 Flat Washer Zink 1 2 06030007 Screw 8 32 Philips Panhead Machine 06030008 Screw 4 40 x 1 2 Philips Panhead Machine x2 HS400 Screw 6 32 Type F Philips Panhead Machine x2 HS407 Screw 10 32 Type F Philips Panhead Machine x5 800231 Screw 6 32 x 5 16 Type F Ph...

Страница 11: ...al Paper Replacement Roll 3 1 8 New XL 15000097 Okidata Printer Old XL 15007052 Okidata DB9 DB25 Printer Adapter Old XL 15020002 Okidata Printer Cable Old XL ALARM OUTPUT WIRING Notes AuditLok XL provides for duress and burglar alarm connections through a cable located at the back of the safe Each alarm is switched via a SPDT relay with both normally open and normally closed contacts provided When...

Страница 12: ...full and or deleting users does not solve the problem run an override to clear the user table or replace the inner board Keyport does not respond Replace the outer board Erratic behavior or corrupt settings Replace the inner board Major historical changes Power Supply Old XL In January 2000 NKL switched from a 9V transformer to a 12V transformer Transformers are not in terchangeable due to differe...