16
NFOD42 Gas Fireplace
INSTALLATION
:$//6:,7&+,167$//$7,21
,1&/8'(':,7+81,7
1) The unit comes with 10' of wire located on the left side of the unit.
2) Install supplied electrical box in desired location.
3) Route low voltage wire through electrical box.
4) Connect 2 wires to switch (use supplied dielectric grease on connections)
5) Install weather resistance cover plate to switch using 2 inner holes with screws provided.
(Ensure gasket and spacer are in place)
6) Mount completed switch assembly with cover plate to the electrical box using 2 outer holes on cover plate. (Shown without facing material)
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
18 GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.
&$87,21
'RQRWZLUHPLOOLYROW
ZDOOVZLWFKZLUHV
WR9ZLUH