background image

REV. B      Page 4

Flat Pan - Match Throw Fire Pits

Table 1

  Fire Pit Dimensions

MODELS

OUTSIDE PAN

DIMENSIONS

A

BURNER 

DIMENSIONS

B

MAX OPENING 

DIMENSIONS

GROUND 

LEVEL

SIDE 

WALL

COMBUSTILE 

CEILING

COMBUSTIBLE 

FLOOR

LOF-2414FHMT-N

24” x 14

(609 x 355mm)

21” x 10”

(609 x 254mm)

22” x 12”

(558 X 330mm)

8”

(203mm)

36”

(914mm)

96”

(2438mm)

18”

(457mm)

LOF-3014FHMT-N

30” x 14” 

(762 x 355mm)

27” x 10”

(686 x 245mm)

28” x 12”

(711 x 330mm)

8”

(203mm)

36”

(914mm)

96”

(2438mm)

18”

(457mm)

LOF-3614FHMT-N

36” x 14”

(914 x 355mm)

33”x10

(838 x 254mm )

38” x 12”

(889 x 330mm)

8”

(203mm)

36”

(914mm)

96”

(2438mm)

18”

(457mm)

LOF-4814FHMT-N

48” x 14” 

(1219 X 355mm)

45”x10”

(1143 x 254mm)

46” x 12”

(1193 x 330mm)

8”

(203mm)

36”

(914mm)

120”

(3048mm)

18”

(457mm)

LOF-6016FHMT-N

60” x 16”

(1524 x 406mm)

57”x10”

(1447 x 254mm)

58” x 14”

(1498 x 381mm)

8”

(203mm)

36”

(914mm)

120”

(3048mm)

18”

(457mm)

LOF-7216FHMT-N

72” x 16”

(1828 x 406mm)

69”x10”

(1752 x 254mm)

70” x 14”

(1803 x 381mm)

8”

(203mm)

36”

(914mm)

120”

(3048mm)

18”

(457mm)

LOF-8416FHMT-N

84” x 16”

(2133 x 406mm)

81”x10”

(2057 x 254mm)

82” x 14” 

(2032 x 381mm)

8”

(203mm)

36”

(914mm)

120”

(3048mm)

18”

(457mm)

LOF-9616FHMT-N

96” x 16”

(2438 x 406mm)

93” x 10” 

(2362 x 254mm)

94” x 14”

(2387 x 381mm)

8”

(203mm)

36”

(914mm)

120”

(3048mm)

18”

(457mm)

A

A

B

B

Fig. 1

 H-style burner pan specifications.

SPECIFICATIONS

Model:

NG 

Orifice

Btu 

Ratings

LP 

Orifice

LOF-2414FHMT-N

#29

75,000

(21.98kW)

#41

LOF-3014FHMT-N

#22

100,000

(29.30kW)

#35

LOF-3614FHMT-N

#16

125,000 

(36.63kW)

#31

LOF-4814FHMT-N

#11

150,000 

(43.96kW)

#29

LOF-6016FHMT-N

#05

175,000 

(51.28kW)

#26

LOF-7216FHMT-N

#02

200,000 

(58.61kW)

#22

LOF-8416FHMT-N

#01

225,000 

(69.94kW)

#19

LOF-9616FHMT-N

25/64”

250,000

(73.26kW)

#12

Disclaimer:

 Btu listings are based on 7.0”WC for Natural Gas and 

11.0”WC for Liquid Propane (LP) at the burner orifice.  Flex line size 

and proper gas pipe sizing will also affect Btu’s.  As a result your 
Btu’s may vary slightly from Table 2 

specifications.

96”/120”

18”

C

ombustible 

Side W

all

Combustible Ceiling

Combustible Floor

CL

36”

     Max 

Overhang

36”

Fig. 2

 Clearance to Combustibles for 

models. (Not to be used in an enclosed 

space)

Table 2

  H-burner specifications.

Содержание LOF-2408FTMT-N

Страница 1: ...s LOF 7216FHMT N 69 x 10 Burner 200 000 Btu s LOF 8416FHMT N 81 x 10 Burner 225 000 Btu s LOF 9616FHMT N 93 x 10 Burner 250 000 Btu s MODELS H Burner Models T Burner Models DO NOT DISCARD THIS MANUAL HAS IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS LEAVE WITH THE HOMEOWNER MODEL SERIAL PN 90105 Natural Gas T Burner Input Rating LOF 2408FTMT N 21 Burner 50 000 Btu s LOF 3008FTMT N 27 Burner 50 ...

Страница 2: ...department DANGER WARNING Do not store or us gasoline or other flammable vapors and liquids in the vicinity of this or other appliances Any LP cylinder not connected for use shall not be stored in the vicinity of this or other appliances WARNING Do not leave unattended during use Do not use for cooking Follow all gas leak procedures in this manual prior to operation WARNING Improper installation a...

Страница 3: ... pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may still cause the media to pop ALWAYS USE CAUTION WHEN USING THE FIRE FEATURE Extra caution should be taken when lighting a fireplace when heavy rains high humidity and moisture are pr...

Страница 4: ...LOF 8416FHMT N 84 x 16 2133 x 406mm 81 x10 2057 x 254mm 82 x 14 2032 x 381mm 8 203mm 36 914mm 120 3048mm 18 457mm LOF 9616FHMT N 96 x 16 2438 x 406mm 93 x 10 2362 x 254mm 94 x 14 2387 x 381mm 8 203mm 36 914mm 120 3048mm 18 457mm A A B B Fig 1 H style burner pan specifications SPECIFICATIONS Model NG Orifice Btu Ratings LP Orifice LOF 2414FHMT N 29 75 000 21 98kW 41 LOF 3014FHMT N 22 100 000 29 30k...

Страница 5: ... 203mm 36 914mm 120 3048mm 18 457mm LOF 9608FTMT N 96 x 8 2438 x 203mm 93 2362mm 94 x 7 2387 x 152mm 8 203mm 36 914mm 120 3048mm 18 457mm SPECIFICATIONS Model MT Natural Gas NG Orifice Btu Ratings LP Orifice LOF 2408FTMT N OAS NG34 50 000 14 65kW OAS LP47 LOF 3008FTMT N OAS NG34 50 000 14 65kW OAS LP47 LOF 3608LTMT N OAS NG29 75 000 21 98kW OAS LP41 LOF 4808LTMT N OAS NG22 100 000 29 30kW OAS LP35...

Страница 6: ...gear Outdoors to consult the installation before proceeding If you move forward and modify a product without consulting Firegear Outdoors cannot be responsible if the product does not operate as designed PREPARING A NON COMBUSTIBLE STRUCTURE The fire pit can be installed on a flat stable surface away from any combustible materials Install fire pit on any level outdoor non combustible flat stable s...

Страница 7: ...he fire pit into the non combustible enclosure Refer to Table 1 dimension A 4 Follow the local code requirements for the gas type being used This fire pit should be installed in accordance with local codes and ordinances or in the absence of local codes with the latest National Fuel Gas Code ANSI Z223 1 NFPA54 or CSA B149 1 Natural and Propane Installation Code in Canada 5 Fire pits create high te...

Страница 8: ...equired for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have proper pressure This chart is for reference only we recommend you consult with a Licensed Plumber Gas Fitter or NFPA54 National Fuel Gas Code current edition for more details Length of Pipe in Feet 1 2 3 4 1...

Страница 9: ...etails Note Be sure to leak test all fitting before operation Fig 5 shows an example of a typical installation Primary Gas Supply O N O F F Fig 6 Key valve components INSTALLATION OF LAVA ROCK MEDIA INTO BURNER PAN Install lava rock media into the burner pan Ensure the media is a minimum of 1 inch diameter for proper operation Note Do not pour Lava Rock directly from bag Media should be placed nat...

Страница 10: ... Wall Material Non Combustible Wall Material Key Valve Key Valve Side View Det a i l Note A 1 x 2 black iron or galvanized coupler nipple not supplied can be used as a spacer between the manual valve and the valve flange to add additional support to hold the manual key valve in place Key Valve Flange Non Combustible Wall Material Non Combustible Wall Material Key Valve Black Iron Nipple Fig 7 Typi...

Страница 11: ...efore each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This appliance is hot when operated and can cause severe burns if contacted 2 Do not burn any solid fuels in this appliance LIGHTING INSTRUCTIONS Key Fig 9 Inserting Key into Valve O N O F F Fig 8 Key Valve Face Butane ...

Страница 12: ...REV B Page 12 Flat Pan Match Throw Fire Pits O N O F F TMSI REPLACEMENT PARTS 1 2 6 7 5 9 10 Drawings not to scale 11 4 3 8 ...

Страница 13: ... Pan Used with 21 T burner 78047 3 30 x 8 LT Flat Burner Pan Used with 27 T burner 1 78057 3 36 x 8 LT Flat Burner Pan Used with 33 T burner 1 78049 3 48 x 8 LT Flat Burner Pan Used with 45 T burner 1 78050 3 60 x 8 LT Flat Burner Pan Used with 57 T burner 1 78051 3 72 x 8 LT Flat Burner Pan Used with 69 T burner 1 78052 3 84 x 8 LT Flat Burner Pan Used with 81 T burner 1 78053 3 96 x 8 LT Flat Bu...

Страница 14: ...urner orifice must be kept a minimum of 6 inches away from the burner connection nipple to prevent any back pressure at the LP orifice See Fig 11 below for details Note It is acceptable to install a 90 elbow if necessary to run the gas line the opposite direction see Fig 12 or 13 A 90 elbow or close nipple are not provided with the kit All NPT pipe threads must be sealed with approved gas Teflon t...

Страница 15: ...op of burner it can inhibit gas from flowing 4 Check gas pressure 5 Ensure thermocouple is correct height Tip of thermocouple should be fully engulfed by flame and approximately 1 35mm to 1 45mm from base of bracket 6 Check thermocouple voltage Minimum voltage to operate system is 12 14mV Low flame 1 Ensure the base media is at least 1 inch in diameter and top media is no more than 1 inch over top...

Страница 16: ...AR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS FIVE 5 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTI...

Страница 17: ...ACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS SANCTUARY SERIES GFRC FIRE FEATURES THREE 3 YEAR WARRANTY GFRC STRUCTURE REFER TO THE APPROPRIATE BURNER SYSTEM FOR WARRANTY WARRANTY COVERS MANUFACTURING DEFE...

Страница 18: ...air the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not c...

Страница 19: ...air the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and replacement Firegear is not responsible for Issues related to gas or electrical installation The Limited Warranty is voided if not assembled installed and operated as intended This Limited Warranty does not c...

Страница 20: ...idental or consequential damages so this limitation or exclusion may not apply to you We do not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and or such representation are binding Firegear Outdoors 17322 Gothard Street Huntington Beach CA 92647 www firegearoutdoors com ...

Страница 21: ...REV B Page 21 Flat Pan Match Throw Fire Pits NOTES ...

Страница 22: ..._ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6 What type of media are you using __________________ 7 Review the troubleshooting section in the installation manual 8 What are the symptoms Please be prepared to explain 9 Be prepared to send photos to us w...

Отзывы: