REV. B Page 4
Flat Pan - Match Throw Fire Pits
Table 1
Fire Pit Dimensions
MODELS
OUTSIDE PAN
DIMENSIONS
A
BURNER
DIMENSIONS
B
MAX OPENING
DIMENSIONS
GROUND
LEVEL
SIDE
WALL
COMBUSTILE
CEILING
COMBUSTIBLE
FLOOR
LOF-2414FHMT-N
24” x 14
(609 x 355mm)
21” x 10”
(609 x 254mm)
22” x 12”
(558 X 330mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-3014FHMT-N
30” x 14”
(762 x 355mm)
27” x 10”
(686 x 245mm)
28” x 12”
(711 x 330mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-3614FHMT-N
36” x 14”
(914 x 355mm)
33”x10
”
(838 x 254mm )
38” x 12”
(889 x 330mm)
8”
(203mm)
36”
(914mm)
96”
(2438mm)
18”
(457mm)
LOF-4814FHMT-N
48” x 14”
(1219 X 355mm)
45”x10”
(1143 x 254mm)
46” x 12”
(1193 x 330mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
LOF-6016FHMT-N
60” x 16”
(1524 x 406mm)
57”x10”
(1447 x 254mm)
58” x 14”
(1498 x 381mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
LOF-7216FHMT-N
72” x 16”
(1828 x 406mm)
69”x10”
(1752 x 254mm)
70” x 14”
(1803 x 381mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
LOF-8416FHMT-N
84” x 16”
(2133 x 406mm)
81”x10”
(2057 x 254mm)
82” x 14”
(2032 x 381mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
LOF-9616FHMT-N
96” x 16”
(2438 x 406mm)
93” x 10”
(2362 x 254mm)
94” x 14”
(2387 x 381mm)
8”
(203mm)
36”
(914mm)
120”
(3048mm)
18”
(457mm)
A
A
B
B
Fig. 1
H-style burner pan specifications.
SPECIFICATIONS
Model:
NG
Orifice
Btu
Ratings
LP
Orifice
LOF-2414FHMT-N
#29
75,000
(21.98kW)
#41
LOF-3014FHMT-N
#22
100,000
(29.30kW)
#35
LOF-3614FHMT-N
#16
125,000
(36.63kW)
#31
LOF-4814FHMT-N
#11
150,000
(43.96kW)
#29
LOF-6016FHMT-N
#05
175,000
(51.28kW)
#26
LOF-7216FHMT-N
#02
200,000
(58.61kW)
#22
LOF-8416FHMT-N
#01
225,000
(69.94kW)
#19
LOF-9616FHMT-N
25/64”
250,000
(73.26kW)
#12
Disclaimer:
Btu listings are based on 7.0”WC for Natural Gas and
11.0”WC for Liquid Propane (LP) at the burner orifice. Flex line size
and proper gas pipe sizing will also affect Btu’s. As a result your
Btu’s may vary slightly from Table 2
specifications.
96”/120”
18”
C
ombustible
Side W
all
Combustible Ceiling
Combustible Floor
CL
36”
Max
Overhang
36”
Fig. 2
Clearance to Combustibles for
models. (Not to be used in an enclosed
space)
Table 2
H-burner specifications.