REV. B Page 14
Flat Pan - Match Throw Fire Pits
CONVERTING TO LP GAS
Table 6
LP conversion chart
Converstion Kit
Common Parts
Btu Ratings
LP Orifice
Models
OAS-LPK47
S499-8,113-SS4-D5,
U3-8D-S
50,000
(14.65kW)
OAS-LP47
LOF-2408FTMT-N
LOF-2408FTMT-N
OAS-LPK41
S499-8,113-SS4-D5,
U3-8D-S
75,000
(21.98kW)
OAS-LP41
LOF-2414FHMT-N
LOF-3608FTMT-N
OAS-LPK35
S499-8,113-SS4-D5,
U3-8D-S
100,000
(29.30kW)
OAS-LP35
LOF-3014FHMT-N
LOF-4808FTMT-N
OAS-LPK31
S499-8,113-SS4-D5,
U3-8D-S
125,000
(36.63kW)
OAS-LP31
LOF-3614FHMT-N
LOF-6008FTMT-N
OAS-LPK29
S499-8,113-SS4-D5,
U3-8D-S
150,000
(43.96kW)
OAS-LP29
LOF-4814FHMT-N
LOF-7208FTMT-N
OAS-LPK26
S499-8,113-SS4-D5,
U3-8D-S
175,000
(51.28kW)
OAS-LP26
LOF-6016FHMT-N
LOF-8408FTMT-N
OAS-LPK22
S499-8,113-SS4-D5,
U3-8D-S
200,000
(58.61kW)
OAS-LP22
LOF-7216FHMT-N
LOF-9608FTMT-N
OAS-LPK19
S499-8,113-SS4-D5,
U3-8D-S
225,000
(65.94kW)
OAS-LP19
LOF-8416FHMT-N
OAS-LPK12
S499-8,113-SS4-D5,
U3-8D-S
250,000
(73.26kW)
OAS-LP12
LOF-9616FHMT-N
When converting Burners to LP gas the main burner orifice must be kept a minimum of 6-inches away from the burner
connection (nipple) to prevent any back pressure at the LP orifice. See Fig. 11 below for details.
Note
: It is acceptable to
install a 90° elbow, if necessary, to run the gas line the opposite direction (see Fig 12 or 13). A 90° elbow or close nipple
are not provided with the kit.
All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound.
Check for any gas leaks before presuming normal operation after conversion is complete.
CAUTION:
Ensure there is ventilation under the burner to provide fresh air for air shutter/orifice.
Burner Pan
GAS FL
OW
½” x 5-inch Nipple
(113-SS4-D5)
½” OAS-LP Orifice
½” Flared Fitting
(U3-8D-S)
½” x ½” Coupling
(S499-8)
Fig. 11
LP conversion illustration.
Fig. 12
Optional LP conversion illustration shows a 90º
elbow (not supplied).
Burner Pan
½” x 5-inch Nipple
(113-SS4-D5)
½” OAS-LP Orifice
½” Flared Fitting
(U3-8D-S)
½” x ½” Coupling
(S499-8)
GAS FLOW
½” 90º Elbow
(not supplied)
Burner Pan
½” x 5-inch Nipple
(113-SS4-D5)
½” OAS-LP Orifice
½” Flared Fitting
(U3-8D-S)
½” x ½” Coupling
(S499-8)
GAS FLOW
½” 90º Elbow
(not supplied)
½” Close Nipple
(not supplied)
Fig. 13
Optional LP conversion illustration shows a 90º