background image

22

Kalea Bay LED Outdoor Fireplace

REV. 4-17-19  Page 16

This fireplace is equipped with LED lighting.  

Preparation for the LED lighting a must be planned before the fireplace 

finish materials are installed

. After the fireplace is set in its final location the LED lighting will need to be installed and 

tested before finishing materials are applied.  You will need to provide the following:

(1) 120VAC GFCI outlet double gang junction box with a weatherproof cover.  Provides power to LED lights and gas valve 

system.  Follow local electrical codes for installation.

A RGB control box with switches is provided with the fireplace. It must be installed within the framing parameters of the 

fireplace. 

Step 1:

 Install the GFCI outlet 

double gang junction box with a 

weatherproof cover on the opposite 

side of the inlet gas supply.  

Note

: This is not a requirement; 

however, with the gang box on the 

opposite side of inlet will create 

more room for LED installation. 

Fig. 15 shows GFCI gang box 

installed.

Step 2: 

Find mounting location for the GFCI gang box.  Fig. 14 shows flat area underneath burner pan.  Mount box 

underneath the burner pan, below the square (cutout) hole area.  Fig. 15 shows the GFCI outlet double gang junction box 

with a weatherproof cover mounted underneath the fireplace.

Burner Pan

Support leg under fireplace

Bo

tto

m

 su

pp

or

t fi

n

GFCI Outlet installed in a double 

outlet NEMA 3R enclosure

(Bring electrical up 

from underneath 

the fireplace)

Fig. 14 

GFCI box location under fireplace

GFCI Outlet installed in a double 

outlet NEMA 3R enclosure

Fig. 15 

Show GFCI box mounted in fireplace

LED LIGHTING INSTALLATION

 

36” Model = 13”

48“ Model = 18”

60“ Model = 24”

72” Model = 30”

5”

11½”

TYP

Electrical Area (GFCI)

The electric junction box (GFCI) with a weatherproof cover must be installed in 

the shaded area shown below.  Ensure the j-box is close to the floor area where 

the fireplace is sitting and not touching the burnerpan.

Fig. 13

 Electrical placement.

KALEA BAY: E LED

Содержание Kalea Bay 0FP-6QLEC0-NLED

Страница 1: ... Failure to provide proper ventilation can void the warranty MODELS MH 60069 Natural Gas Description OFP 36LECO NLED 36 Open Front Fireplace OFP 48LECO NLED 48 Open Front Fireplace OFP 60LECO NLED 60 Open Front Fireplace OFP 72LECO NLED 72 Open Front Fireplace Kalea Bay Outdoor Gas Fireplace with LED Lighting Installation and Operating Instructions LED MODEL DO NOT DISCARD THIS MANUAL HAS IMPORTAN...

Страница 2: ...ing can affect Btu s As a result your Btu s may vary slightly from Table 1 specifications NOTE These fireplaces come shipped as Natural Gas models only There is an LP conversion kit available as an accessory Ensure you order the specific conversion kit for your model fireplace Table 1 shows the applicable information if converting to Liquid Propane LP gas See page 32 IMPORTANT It is permissible to...

Страница 3: ... Clearance To Combustible Ceiling OFP 36LECO NLED 40 36 37 16 16 11 10 6 42 OFP 48LECO NLED 52 48 37 16 16 11 10 6 42 OFP 60LECO NLED 64 60 37 16 16 11 10 6 42 OFP 72LECO NLED 76 72 37 16 16 11 10 6 42 Fig 6 Single sided fireplace clearance to combustibles See Table 3 Fig 7 Open front fireplace mantel clearances FRONT VIEW TOP VIEW END VIEW E E C 6 20 F D A B G Bottom Finish Fin Hood Typ Each Side...

Страница 4: ...ce refer to Table 4 SINGLE SIDED FRAMING DIMENSIONS WITH METAL STUDS Table 5 Fireplace framing dimensions NOTE This fireplace requires metal studs for framing WOOD STUDS ARE NOT PERMITTED A B Metal Studs Metal Studs Metal studs shown in gray Bottom Support Fin Hood C Metal Studs Metal Studs Front NOTE This outdoor fireplace is not a load bearing fireplace All finishing materials must be supported ...

Страница 5: ...de Wall I Clearance To Combustible Ceiling OFP 36LECO NLED 40 36 37 16 16 11 10 36 42 OFP 48LECO NLED 52 48 37 16 16 11 10 36 42 OFP 60LECO NLED 64 60 37 16 16 11 10 36 42 OFP 72LECO NLED 76 72 37 16 16 11 10 36 42 Fig 10 See through fireplace clearance to combustibles See Table 6 I H END VIEW S I D E W A L L CEILING FLOOR 11 Front Front This fireplace ships from the factory as a single sided fire...

Страница 6: ...RAMING DIMENSIONS WITH METAL STUDS Table 7 Fireplace framing dimensions NOTE This outdoor fireplace is not a load bearing fireplace All finishing materials must be supported by the surrounding structure and not rely on the fireplace itself A B Metal Studs Metal Studs Metal studs shown in gray Bottom Support Fin Hood C Metal Studs Metal Studs Top view showing lip using non combustible facing materi...

Страница 7: ...the opposite side of inlet will create more room for LED installation Fig 15 shows GFCI gang box installed Step 2 Find mounting location for the GFCI gang box Fig 14 shows flat area underneath burner pan Mount box underneath the burner pan below the square cutout hole area Fig 15 shows the GFCI outlet double gang junction box with a weatherproof cover mounted underneath the fireplace Burner Pan Su...

Страница 8: ...ll a total of 4 retainer clips two on open side LED Retainer Clip Fig 17 Shows clip installed on right side of fireplace Wire Grommets Fig 16 Locating wire grommets Step 4 Install the four 4 windshield clips two on each side one at the top and one with the LED retainer clip as shown in Fig 18 Note if you are preparing a see through fireplace you will install a total of 8 windshield clips four on e...

Страница 9: ...ip and channel the same direction Wire Grommet Bottom End LED Channel Assembly Fig 20 Installing LED lights and channel Fig 21 LED installed in retainer clip inside fireplace LED LIGHTING INSTALLATION Step 5 Remove the LED right channel assembly from the carton The front of the channel has a shield facing the front with the LED wire hanging on the right side See Figs 19 21 for details Note If you ...

Страница 10: ...or in one direction Once locked in position screw the threaded cap of the female connector securely over the male connector See Fig 23 Step 9 Attach 77110 to 77111 using the molex connectors After connecting the LED lights into the 77111 wire harness insert the 12 volt adapter 77102 with terminals into the red black wires of LED wire harness Plug the 12 volt adapter into the 120VAC GFCI box with w...

Страница 11: ...e The wires from the switches can be removed for eaiser installation if needed Ensure to match the wires with the labels for each switch when reattaching Step 13 Remove the 8 PIN module wire harness 77116 from the components part box Locate the 8 PIN male connector from the valve box under the fireplace and connect it to the 8 PIN female end of the wire harness Connectors only attach one way press...

Страница 12: ...00ADP48EX 77102 77114 77113 77111 LED Tray Assy 77110 77102 D e t a i l o f Hidden wires Fig 26 Overview of fireplace wiring to control box Note The fireplace is provided with 10 feet of wire If you require a longer length an optional 10 foot wire harness 77116 77111 are available in replaemet parts section LED LIGHTING INSTALLATION KALEA BAY ECOFLOW LED ...

Страница 13: ...RESENTS COMPONENTS INSIDE LED CONTROLLER BOX 12VDC adapter inside a weatherproof box REPRESENTS COMPONENTS INSIDE FIREPLACE AF 4000ADP24 7 5VCD adapter powers gas valve system Brown Blue Yellow Black Red Note If using single sided fireplace only one LED connection will be used AF 4000ADP48EXT Fig 27 This wiring diagram shows the LED circuit in relationship to the IPI gas valve control system Each ...

Страница 14: ...LET PILOT TUBE S I SWITCHES POWER MOTOR COMM BATT V BRONZE INSULATED WIRE BLACK WIRE BRASS WIRE GROUND MOTOR DRIVE WIRES TO 120VAC POWER SWITCHES MOUNTED IN RGB CONTROL ASSEMBLEY LOW RATE SET SCREW Fig 28 This wiring diagram shows the components inside the valve box The dotted line box shows the components external of the valve box GAS VALVE WIRING DIAGRAM KALEA BAY ECOFLOW LED ...

Страница 15: ...ig 31 This is a good time to double check for any gas leaks or electrical connections before finalizing the installation by installing the glass media Fig 31 Proper pilot flame through ignition hole INSTALLING MEDIA Use Firegear Outdoors large broken glass media not supplied Table 8 will specify the proper amount needed Place fireglass media into the trough area first as shown in Fig 32 Use the re...

Страница 16: ...wall switch ON OFF ONLY Model 1001D ATX Wireless Wall Switch Timer 4 Button Wall Timer 30 60 120 OFF Model TM R AF1TX Home Automation System Model AF 4000HAT Enables the fireplace to operate with a home automation device Additional Remotes Model RCAF 3TX hand held remote Twig Set Model 926 930 6 piece Beach Driftwood twisted twig set NOTE Logs cannot be placed directly on the burner They must be p...

Отзывы: