background image

REV. A             Page 17

FPB Pro Spur Burners Fire Pits with MT System

The end-user must provide a bill of sale, canceled check, or payment record to verify the purchase date and to establish 

the warranty period. This Limited Warranty shall be valid and limited to the 

original purchaser only.

WARNING:

 

 Any modification to the product will void the warranty.

This Limited Warranty shall be limited to the repair and/or replacement of parts that have been proven to be defective 

under normal use and service. All warranty claims must be made by the 

OEM/Distributor/Dealer account on behalf of the end-user. You may contact Technical Support at 

800-966-8126.

Our Technical Service Department must confirm all approved defects. If a defect is confirmed and we approve the claim, 

we will replace such parts without charge. This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state.

The manufacturer may request defective products returned with an RMA (Return Merchandise 

Authorization) issued by Firegear Outdoors for specific products, which is considered to be the 

nature of the defect and or warranty claim. Product to be returned should; be packed so as not to incur damages during 

transportation. Firegear is not responsible for damages on returned items. RMA is valid for thirty (30) days from the date 

issued. The RMA must be clearly marked on the outside of the package.

Please check with your local building code department or governing agency for proper approvals 

before purchasing. Firegear Outdoors is not responsible for any violation of local codes.

Travel, diagnostic cost, service labor to repair the defect on warranty parts to and from the factory will be the responsibility 

of the owner. We will not be responsible for labor charges and/or damage 

incurred in installation, repair, and replacement. Firegear is not responsible for Issues related to gas or electrical installa-

tion.

The Limited Warranty is voided if not assembled, installed, and operated as intended. This Limited Warranty does not 

cover any defects due to accident, abuse, misuse, alteration, misapplication, 

vandalism, improper installation or improper maintenance or service, removal from the original 

location, or re-installation into another location, or failure to perform normal and routine maintenance.

Damage due to severe weather conditions such as hail, hurricanes, earthquakes, tornadoes, 

discoloration due to overheating, exposure to chemicals (including chlorine and salt), either directly or in the atmosphere, 

or very high humidity, is not covered by this Limited Warranty. Costal, humid and/or salt environments are subject to man-

ufacturer review. All out-of-box claims must be made within 30 days of purchase and must be made prior to installation. 

Any product installed damaged will be 

considered damaged during installation and not covered under warranty.

There are no other express warranties except as set forth herein. For consumer applications, any 

applicable implied warranties of merchantability and fitness are limited induration to the period of 

coverage of this Limited Warranty. Some states do not allow limitation on how long an implied 

warranty lasts, so this limitation may not apply to you.

For Commercial Applications, the liability of Firegear Outdoors is limited to the express terms of this warranty. We ex-

pressly disclaim any and all implied warranties, including any warranties of fitness for a particular purpose or merchantabi-

lity.

Содержание FPB-25SFPSBR21 MT-N

Страница 1: ...of cross ventilation Failure to provide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 26DPSBR21MT N FPB 26DPSBR21MT P 19 Round Pan with 21 Pro Brass...

Страница 2: ...ff gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoli...

Страница 3: ...s happens the media has the potential to crack or pop outside the fireplace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling...

Страница 4: ...s A Disc Depth B Disc Diameter C Burner Size Min Opening D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor FPB 26DPSBR21MT N FPB 26DPSBR21MT P 1 16 26 Rd 21 24 8 36 120 18 FPB 29DPS...

Страница 5: ...s required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have prop...

Страница 6: ...ontents The box includes a flex gas line key valve flange key and flared fitting with nipple Inspect for any damage or missing parts See Fig 4 Install the flared fitting and nipple into the bottom of...

Страница 7: ...ten 2 Extend the gas supply system using minimum of black iron pipe or an approved flexible gas line from existing house supply This can be accomplished by teeing off or tapping into a gas line connec...

Страница 8: ...outdoor use only Not approved for any indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not cover more than 1 above the...

Страница 9: ...s Supply Key Valve Side View Det a i l Fig 7 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple n...

Страница 10: ...connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This ap...

Страница 11: ...REV A Page 11 FPB Pro Spur Burners Fire Pits with MT System MT REPLACEMENT PARTS 1 2 6 3 8 4 9 10 Drawings not to scale O N O F F 7 5...

Страница 12: ...ur fire pit to protect it from humid rainy weather conditions when not in use Heavy rains downpours could affect the fire pit operation if not covered if this occurs ensure you allow the fire pit time...

Страница 13: ...Web Site www firegearoutdoors com 800 966 8126 See Firegear Outdoors catalog for other accessories E STOP Gas shut off valve with mechanical timer and emergency shut off Models ESTOP1 0H 1 hour timer...

Страница 14: ...D S Fitting Fire Pit Disc Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads...

Страница 15: ...VE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME...

Страница 16: ...FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR...

Страница 17: ...o repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and rep...

Страница 18: ..._______ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6...

Отзывы: