Round/Square Flat Disc Fire Pits
CONVERTING TO LP GAS
Table 6
LP conversion chart
Converstion Kit
Common Parts
Btu Ratings
LP Orifice
OAS-LPK31
#SS499-8, #113SS4-D5,
U3-8D-S
125,000
(36.63kW)
OAS-LP31
OAS-LPK26
#SS499-8, #113SS4-D5,
U3-8D-S
175,000
(51.28kW)
OAS-LP26
OAS-LPK12
#SS499-8, #113SS4-D5,
U3-8D-S
250,000
(73.26kW)
OAS-LP12
When converting Burners to LP gas the main burner orifice must be kept a minimum of 6-inches away from the burner
connection (nipple) to prevent any back pressure at the LP orifice. See Fig. 14 below for details.
Note
: It is acceptable to
install a 90° elbow, if necessary, to run the gas line the opposite direction (see Fig 15 or 16). A 90° elbow is not provided
with the kit
.
All NPT pipe threads must be sealed with approved gas Teflon tape or pipe compound.
Check for any gas leaks before presuming normal operation after conversion is complete.
CAUTION:
Ensure there is ventilation under the burner to provide fresh air for air shutter/orifice.
Burner Pan
GAS FL
OW
½” x 5-inch Nipple
(113SS4-D5)
½” OAS-LP Orifice
½” Flared Fitting
(U3-8D-S)
½” x ½” Coupling
(SS499-8)
Fig. 14
LP conversion illustration.
Fig. 15
Optional LP conversion illustration shows a 90º
elbow (not supplied).
Burner Pan
½” x 5-inch Nipple
(113SS4-D5)
½” OAS-LP Orifice
½” Flared Fitting
(U3-8D-S)
½” x ½” Coupling
(SS499-8)
GAS FLOW
½” 90º Elbow
(not supplied)
Burner Pan
½” x 5-inch Nipple
(113SS4-D5)
½” OAS-LP Orifice
½” Flared Fitting
(U3-8D-S)
½” x ½” Coupling
(SS499-8)
GAS FLOW
½” 90º Elbow
(not supplied)
½” Close Nipple
(not supplied)
Fig. 16
Optional LP conversion illustration shows a 90º
elbow and close nipple (not supplied).