REV. B Page 10
Round & Square Flat Disc
SECTION
A THERMOCOUPLE MANUAL
SAFETY
(TMSI) INST
ALLA
TION
Fig. 7
TMSI typical installation.
Gas Outlet
to Fire Pit
Gas Inlet
Thermocouple
Lead
PIEZO48WH
PIEZO23WH
+
-
AAA
Plastic Nut
Red Button Cap
Mounting Plate
Illustration shows side view of valve and Piezo ignitor.
Remove red button cap and install battery into Piezo
ignitor module.
Illustration above shows ground tab
connection underneath the burner pan.
INSTALLING GAS VALVE
The gas valve is secured into the mounting plate with a nut.
Fig. 7 shows an example of a typical installation.
Gas Supply
Flat Disc
Non-Combustible Enclousure
Shut-Off
Spur Burner
OFF
Gas Valve
TC Wire
Piezo
Gas valve and flexible gas lines are supplied; gas shut-off is not, but available in accessories page 27. Flex lines with
flared fittings do not require Teflon tape or pipe compound. Ensure not to “kink” the flex lines to allow better gas flow of
gas. The illustration above is only a guide for the gas connection. Local codes may require different methods to connect
the gas supply.
Note: See optional mounting method of TMSI face plate on back of this manual.
Fig. 8
Typical installation.
Ratin
g Pla
te
Bottom of Burner Pan
PIEZO48WH
Piezo Ground Tab