Страница 1: ...EL LE ES SS S G GA AS S F FI IR RE E M MO OD DE EL L L L2 23 3G G I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D U US SE ER R I IN NS ST TR RU UC CT TI IO ON NS S All instructions must be handed to u...
Страница 2: ...FL05 FL06...
Страница 3: ...d by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room vol ume in ft3 by 35 3 This appliance is intended as a secondary source of heat only and should not be used in a...
Страница 4: ...only in a suffi ciently ventilated space A minimum of 100cm2 15 5 in2 purpose provided ventilation is required for this appliance an openable window or louvre is also required To reduce the possibilit...
Страница 5: ...a home however there are exceptions and the appliance may not be used in the following rooms Bedrooms or areas which are mainly used for sleeping Bathrooms or areas where large amounts of steam are l...
Страница 6: ...positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positi...
Страница 7: ...e gas supply pipework to enter the appliance firebox These entry points are knock out type holes Non concealed gas connections may be made using the entry points at either end of the firebox or the on...
Страница 8: ...tely 5mm from the wall Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance Insert the lower fixing screws into the lower wall plugs through...
Страница 9: ...f under any circumstances the piezo electric spark fails the pilot can not be lit manually SETTING PRESSURE The pressure test point is located on the left hand side of the appliance on the main burner...
Страница 10: ...n in order to create a 2mm gap shown Simply hang the facia panel onto the outer casing ensuring that the corresponding keyhole shaped holes engage the screw heads fully BRIEFING THE CUSTOMER All instr...
Страница 11: ...main burner pipes and blow through to dislodge any debris Now remove the restric tor elbow and blow through to make sure it is entirely clear Unclip the pilot lint gauze and clean with a soft brush Cl...
Страница 12: ...gure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide the concentration of carbon monoxide CO expressed in percent by the concentration of car bon dioxide CO2 to obtain the applianc...
Страница 13: ...tray realign HT lead Fire runs for a time and then cuts off Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If th...
Страница 14: ...bracket Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embossed paper low temperature surrounds etc may discolour if fitted too close to the fire See...
Страница 15: ...or discolouration may occur over time The appliance must not be positioned vertically within 100 mm of a carpeted floor rugs or fabric materi als of any kind This dimension is measured vertically to t...
Страница 16: ...or or window has been opened cre ating a draught then pilot disturbance could be the problem and removal of the draught should resolve this The appliance can then be re lit in accordance with the prev...