FireBird System 120 Скачать руководство пользователя страница 24

terMs & CondItIons oF warranty

Firebird products are designed and manufactured to give 
many years of trouble free service.

The terms laid down in the warranty must be adhered to.

u

  Firebird  provides  a  comprehensive,  conditional           

warranty of 5 years on the boiler shell and 2 years 
on     all other parts from date of installation, provided   
installation has occurred within 12 months from date 
of purchase.

u

  The 5 year boiler shell warranty consists of parts and 

labour for the first 3 years and parts only for years 4 and 
5.

u

 The warranty will only apply if the boiler is 

commissioned by an OFTeC registered or competent, 
qualified engineer and is serviced annually thereafter.

u

  Correct commissioning will ensure that your boiler is 

set to operate at its maximum fuel efficiency.

u

  Consumable components, the nozzles and the oil hose 

are excluded.

terMs & CondItIons oF warranty 

1.  Warranty implies that the product shall be free from 

defective parts or workmanship for a period of warranty 
cover, which begins from the date ofinstallation.

2.  all claims under the warranty programme must be 

within the time limits stated on the left.

3.  Installation and commissioning of the product must 

be  in  accordance  with  (a)  instruction/technical            
manuals  (b)  all  relevant  standards  and  codes  of           
practice.

4.  a competent, qualified engineer, using the correct 

installation  and  test  equipment  must  carry  out        
installation and commissioning.

5.  This warranty does not cover special, incidental or 

consequential damages, injury to persons or property, 
or any other consequential loss.

6.  Servicing of the boilers is to be carried out annually to 

maintain the manufacturer’s warranty.

7.  Firebird accepts no liability in respect of any defect 

arising from incorrect installation, negligence, 
fair  wear  and  tear,  misuse,  alteration  or  repair  by                
unqualified persons.

8.  Firebird will not accept any liability in respect of any 

defect occurring to the product due to limescale 
build-up and or low return water temperature.

9.  The warranty programme extends to reasonable 

labour costs eXCePT in the case of a 5 year warranty 
period whereby any valid claim made after 3 years will 
not include labour costs.

10.  Firebird’s prior authorisation must be obtained before 

examination or repair of the product takes place.

11.  Firebird  will  examine  all  claims  made  under  the            

warranty programme and for any claims that are 
deemed invalid, the costs incurred will be borne by 
the owner.

12. The warranty programme only applies where the 

product  was  used  for  normal  domestic  heating               
purposes.

13. any defective part removed under any or all of the 

warranty programmes MUST be returned to Central 
Heating New Zealand.

14. Burner controls and flue kits (supplied by Firebird), 

will be free from defective parts or workmanship for a 
period of 2 years form the date of installation (with the 
exception of burner nozzles, which must be replaced 
at the recommended service intervals).

STATUTORY RIGHTS OF THE OWNER ARE NOT

AFFECTED BY THIS WARRANTY

7

24

Содержание System 120

Страница 1: ...manual must remain with the householder once installation is complete HEATING SOLUTIONS ENVIRONMENT INNOVATION TECHNOLOGY Technical Manual Standard Efficiency Indoor Boiler System 90 26kW System 120...

Страница 2: ...ulations 5 3 1 Flue Regulations 6 3 2 Flue Systems 8 3 3 Liquid Fuel Supply 11 4 SYSTEM BOILER 4 1 End User Information 12 4 2 Installer Guidelines 13 4 3 Technical Details 17 5 COMMISSIONING 21 6 Ser...

Страница 3: ...erform reliably and as a regular check on its built in safety features It is important that servicing should be conducted by a competent engineer such as one who is OFTEC trained and registered All ap...

Страница 4: ...be sought following eye contact or prolonged reddening of the skin The small quantities of adhesives and sealants used in the product are cured They present no known hazards when used in the manner fo...

Страница 5: ...RMA Clean Air Approval number of BUR0801 This appliance and flue system has been tested by CRL Laboratories in New Zealand Certificate number 07 41180 and can be installed to meet the requirements of...

Страница 6: ...C D K F F L N O P H J Boundary Boundary F Q Q Q Q Q Q Q R Pressure Jet Location Appliance Burner Type Non Condensing ROI NI A Directly below an opening airbrick opening window etc 600mm B Horizontall...

Страница 7: ...for low level flue and low level balanced flue discharge when tested to BS EN 303 1 5 Terminating positions must be at least 1 8m distant from a fuel storage tank unless a wall with at least 30 minute...

Страница 8: ...ax length 6m Overall length must take into account bends where 45 bend 0 5m length and 90 bend 1m length INSTALLATION INSTRUCTIONS SUPPLIED WITH ALL FLUE KITS Elbows 45 90 Adjustable extensions 305 42...

Страница 9: ...pipe to ensure a positive seal IMPORTANT A 50mm 2inch gap must be left between the cone cowl and the wall Ensure Combustion air pipe protrudes beyond the outer surface of the wall GAS GAS GAS GA S GA...

Страница 10: ...ipe protrudes beyond the outer surface of the wall Flue extension for right hand outlet Push the flue pipe through the 125mm hole in the wall Apply high temperature sealant to the O ring on the inner...

Страница 11: ...allow household waste or hot ashes container in vicinity of oil storage tank or boiler flue outlet 11 Flexible Oil Pipe s Two flexible burner Diesel hoses are supplied with the boiler which must be w...

Страница 12: ...ent of the control thermostat failing and keeps the boiler safe The safety high limit thermostat will shut the boiler off and will require the limit button to be pushed to restart the boiler It is rec...

Страница 13: ...c pipe from overheating Additional measures must be incorporated into the system pipework for protection in these circumstances Plastic pipe must never be connected directly to the boiler and there mu...

Страница 14: ...sured in bar equals static head of system measured in bar plus 0 3 Sealed Heating Circuit The system must comply with BS 7074 Part 1 and BS 5449 Part 1 with a maximum water temperature of 80 C A manua...

Страница 15: ...s cold water is supplied through the boiler drain fill valve Heating Circuit This is the heating system including the boiler which is filled from the mains supply via a flex filling loop to a pressure...

Страница 16: ...erate the post purge function on the burner when applicable If a permanent live supply is not provided the burner will not operate Mains Burner Limit Lockout WIRING Electrical Supply The boiler and co...

Страница 17: ...Standard Efficiency output range Weight kg Dimensions mm H W D A B C E F G I J K L System 90 26kW 148 856 555 618 760 231 165 210 580 648 341 78 62 93 System 120 35kW 151 856 555 618 760 231 165 210...

Страница 18: ...ue elbow adaptor 210249 6 1 Gasket seal 110555 7 1 Stat pocket ACC003PKT 8 1 Air hose ACC000SSH 9 1 Control panel 314734 10 1 Casing left side 214744 11 1 Casing side cover 214748 12 1 Casing right si...

Страница 19: ...0555 7 1 Stat pocket ACC003PKT 8 1 Flue elbow adaptor 210249 9 1 Bolt M8X150 110437 10 1 Air hose ACC000SSH 11 1 Control panel 314734 12 1 Casing left side 214744 13 1 Casing side cover 214748 14 1 Ca...

Страница 20: ...er 15 mm dia 15 mm dia Circulating Pump 25 60 25 60 Integral Expansion Vessel Normal Capacity 12 litres 12 litres Expansion Vessel Pre charge Pressure 1 bar 1 bar Low Pressure Water Switch Filling Loo...

Страница 21: ...e a smoke gun to check clean combustion Flue gas analysis and fine tuning of burner u Ensure flue gas is over 50 C when setting CO2 u Allow the boiler to run for a period of time before fine tuning to...

Страница 22: ...matter Refill the system and again vent at all points as described Examine the complete system for water leaks having pressurised it to 1 2 5 bar Correct any leaks then check operation of the safety...

Страница 23: ...leaks Draw off any accumulated water and sludge from the tank by opening the drain valve Turn off the diesel supply and remove the filter bowl then wash the element clean with diesel Fit a new element...

Страница 24: ...nd commissioning 5 This warranty does not cover special incidental or consequential damages injury to persons or property or any other consequential loss 6 Servicing of the boilers is to be carried ou...

Страница 25: ...Valve Location Condensate Trap where fitted Condensate Trap Piped to Drain Condensate Trap Primed Float and Condensate Trap in Place Check Flue Seals Deflector Plate and Baffles Graphite Door Seal and...

Страница 26: ......

Страница 27: ......

Страница 28: ...the specification of our products at any time and be without obligation to make similar changes in products previously produced MLOBNZEBSE000 For further information on Firebird products please conta...