4.0 INSTALLATION INSTRUCTION
4.1 PERFORMANCE
The following highlights the output and test performance of the inset stove:
Fuel Type
Wood
Ancit
Ancit
Output to Water - kW
7.3
8.3
7.2
Output to Space - kW
2.5
3.6
0.1
Efficiency - %
75
79.9
81.5
CO (@13% O
2
)
0.61
0.36
0.44
Mean Flue Gas Temp ˚C
276
228
216
Flue Gas Mass Flow g/s
8.6
7.5
5.2
BS Standard
BS EN 13229:2001
Weight - kg
96.6
Test Type
Intermittent
Intermittent
Continuous
Maximum water operating pressure: 3 bar. Minimum safe distance from
combustible materials: sides 75mm and shelf 200mm.
Fuel Type
Wood
Ancit
Ancit
Output to Water - kW
6.9
12.1
7.1
Output to Space - kW
3.6
3.6
1.7
Efficiency - %
77.0
81.0
79.6
CO (@13% O
2
)
0.91
0.43
0.41
Mean Flue Gas Temp ˚C
277
317
222
Flue Gas Mass Flow g/s
7.3
8.3
8.1
BS Standard
BS EN 13229:2001
Weight - kg
102.4
Test Type
Intermittent
Intermittent
Continuous
Maximum water operating pressure: 3 bar. Minimum safe distance from
combustible materials: sides 75mm and shelf 200mm.
Heat outputs and efficiencies are based on heat over a one hour period, using Ancit solid
fuel. Outputs are obtained by independent testing to BS Standard EN 13229, burning Ancit
solid fuel.
The appliance is capable of intermittent operation when burning wood logs and
both intermittent and continuous operation when burning smokeless fuel.
Firebird 16” Multifuel Backboiler Inset Stove
Firebird 18” Multifuel Backboiler Inset Stove
Ancit = Smokeless Coal
4
Содержание Multifuel Backboiler Inset Stove Series
Страница 1: ...Instruction Manual Multifuel Backboiler Inset Stove HEATING SOLUTIONS ...
Страница 2: ......