FireBird Multifuel Backboiler Inset Stove Series Скачать руководство пользователя страница 20

Photographs, Illustrations & Specifications.  This catalogue was correct at the time of going to print.  However, Firebird’s policy is one of continuous development.  
The right is reserved to change specifications, colour, and prices of the models and items illustrated and described in this publication at any time.  Whilst every care 
has been exercised in the production of this catalogue, Firebird cannot accept any liability for errors or omissions.   For the latest details always consult Firebird.           

MLIS004

Republic of Ireland

Firebird Heating Solutions Ltd.,

Údarás Industrial Estate,
Baile Mhic Íre,
Co. Cork, 
Ireland.

t:

 +353 (0)26 45253 

f:

 +353 (0)26 45309 

e: 

[email protected]

www.firebird.ie

United Kingdom

Firebird Heating Solutions Ltd.,

Central Avenue,
Lee Mill Industrial Estate,
Nr. Ivybridge,
Devon  PL21 9PE
United Kingdom.

t:

 +44 (0)1752 691177 

f:

 +44 (0)1752 691131  

e: 

[email protected]  

www.firebirduk.co.uk

Northern Ireland

Firebird Heating Solutions Ltd.,

Shean,
Forkhill,
Newry,
BT35 9SY.

t:

 +44 (0)28 3088 8330 

f:

 +44 (0)28 3088 9096 

e: 

[email protected]

www.firebird.ie

Содержание Multifuel Backboiler Inset Stove Series

Страница 1: ...Instruction Manual Multifuel Backboiler Inset Stove HEATING SOLUTIONS ...

Страница 2: ......

Страница 3: ...g 11 4 11 Commissioning 11 5 0 OPERATING INSTRUCTIONS 5 1 Fuels 12 5 2 Lighting and Controlling 12 5 2 1 Wood 12 5 2 2 Smokeless Fuel 13 5 3 Overnight Burning 13 5 4 Clearance of Ash 14 5 5 Throat Plate Baffles 14 5 5 1 Initial Burning 14 5 5 2 Regular Checking 14 5 6 CO Alarms 14 5 7 Extractor Fans 14 6 0 MAINTENANCE 6 1 Cleaning 14 6 2 Door Seals 14 6 3 When Not in Use 14 6 4 Chimney Cleaning 15...

Страница 4: ... no cracks or openings are evident and that the seals on the inset stove are in good condition ENSURE THE BAFFLES ARE ALWAYS IN PLACE WHEN LIGHTING THE INSET STOVE AND NEVER LIGHT A FIRE IF THE BAFFLES ARE NOT IN PLACE THE INSET STOVE DOOR SHOULD NOT BE KEPT OPEN WHEN THE FIRE IS LIT BURNING The inset stove should never be over stocked over filled The draught settings should be reduced if this occ...

Страница 5: ... and returned to Firebird within 28 days of complete installation and commissioning The following terms laid out in the warranty must be adhered to a All claims under the warranty must be within the above stated time limits b Warranty implies that the product shall be free from defective parts or workmanship for a period of warranty cover which begins from the date of installation c The inset stov...

Страница 6: ... to Space kW 3 6 3 6 1 7 Efficiency 77 0 81 0 79 6 CO 13 O2 0 91 0 43 0 41 Mean Flue Gas Temp C 277 317 222 Flue Gas Mass Flow g s 7 3 8 3 8 1 BS Standard BS EN 13229 2001 Weight kg 102 4 Test Type Intermittent Intermittent Continuous Maximum water operating pressure 3 bar Minimum safe distance from combustible materials sides 75mm and shelf 200mm Heat outputs and efficiencies are based on heat ov...

Страница 7: ...e skin In case of contact wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the possibility of personal injury 4 3 AIR SUPPLY It...

Страница 8: ...lled on a hearth that can take the weight and is of a non combustible material Ensure that when installing the appliance the following regulations are met IRL Building Regulations 1997 Technical Guidance Document 5 states that the hearth must extend in front of the appliance by 500mm and to the sides by 150mm UK Building regulations for class 1 appliances state that the hearth must extend in front...

Страница 9: ...ble material If the stove is filled in place of an open fire the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire 4 7 INSTALLING AND BACK FILLING 1 Remove the inset stove from its packaging and inspect for any damage 2 Place adjustable legs to the bottom of the inset stove if...

Страница 10: ...oint where the chimney narrows Ensure that the flue manufacturer s instructions are adhered to at all times 12 All voids must be filled and the flue pipe flaunched into the chimney so that no soot can collect when sweeping the chimney 13 Make good the holes in the front and side of the chimney breast ensuring they are airtight Remove any material from inside the appliance and check the flue pipe i...

Страница 11: ...tallation 60 60 min 415 for 16 inset min 350 mm for 18 inset min 400 mm to open door Fireplace surround Inset facia Inset stove Fixing screws Allow access from side of chimney breast to facilitate pipework installation X X Limiting dimensions of hearth ...

Страница 12: ...flow 28 mm Gravity radiator Feed and expansion tank Open vent 22 mm Open vent 22 mm Circulating pump Drain cock at lowest point Back boiler Central heating return Central heating flow Drain cock Domestic hot water draw off Overflow Overflow Cold water tank Indirect hot water cylinder Minimum return thermostat Gravity return 28 mm Gravity flow 28 mm Gravity radiator Feed and expansion tank Open ven...

Страница 13: ...t stove allow sufficient time for the back fill to dry at normal conditions The following checks should be carried out prior to lighting a fire in the inset stove 1 The fire grate is in place 2 The flue is clear 3 Ensure that baffles are in place 4 Check the door fitting 5 The system is full with water and vented 6 Has a suitable inhibitor been added 4 11 COMMISSIONING Light the fire and check all...

Страница 14: ...oatings and preservatives should not be used Not only does it release noxious chemicals into the air but it can also contribute to the amount of tar and deposits building up in your chimney NOTE You should never over stock over fill your inset stove This is necessary to avoid fuel falling out onto the glass door and also to avoid chimney fires Best practice is not to fill above the front frame of ...

Страница 15: ...close the door Once the new fuel has taken adjust the secondary air control 5 2 2 SMOKELESS FUEL The same applies as with wood but you will require more primary air than secondary air with smokeless fuel When burning Homefire or Anthracite smokeless fuel always have the secondary air fully open on ignition Leave it open for 3 5 minutes and adjust thereafter 5 3 OVERNIGHT BURNING To achieve slow bu...

Страница 16: ...be done on a regular basis about once a month or more as deemed necessary 5 6 CO Alarms Your installer should have fitted a CO alarm in the same room as the appliance see also section 4 11 If the alarm sounds unexpectantly follow the instructions under item no 6 6 below 5 7 Extractor Fans Do not fit an extractor fan in the same room as this stove This may cause the stove to emit fumes into the roo...

Страница 17: ...6 6 FUME EMISSION Properly installed operated and main tained this stove will not emit fumes into the dwelling Occasional fumes from de ashing and re fuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If fume emission does persist then the following immediate action should be taken 1 Open all windows and doors to ventilate the room 2 Let the fire...

Страница 18: ...t blocked FIRE NOT RESPONDING TO AIR CONTROLS OVER BURNING Check that The door is fully closed Both air controls to the appliance are fully closed The door seals are in place and in good condition The correct fuel is being used REDUCING BLACKENING OF GLASS This stove is designed with an air wash the function of which is to reduce deposits on the glass Please note that certain fuel types can cause ...

Страница 19: ...on Chimney cleaned Stainless steel relining Flue system sealed Flue diameter minimum flue diameter of 150mm Flue Draught Flue draught test complete Result of test min 12 Pascal s draught Handover Details First ignition of stove complete Operation and controls confirmed Manuals handed to householder INSTALLER SIGNATURE DATE HEATING SOLUTIONS HOUSEHOLDER Name Address Tel Please complete the followin...

Страница 20: ... or omissions For the latest details always consult Firebird MLIS004 Republic of Ireland Firebird Heating Solutions Ltd Údarás Industrial Estate Baile Mhic Íre Co Cork Ireland t 353 0 26 45253 f 353 0 26 45309 e info firebird ie www firebird ie United Kingdom Firebird Heating Solutions Ltd Central Avenue Lee Mill Industrial Estate Nr Ivybridge Devon PL21 9PE United Kingdom t 44 0 1752 691177 f 44 ...

Отзывы: