HealtH & saFety inFoRMation

tHis PRoDuCt Has Been DesigneD to tHe FolloWing 
stanDaRDs: 

this equipment complies with the low voltage Directive 
2014/35/eu and Directive 2014/30/eu.

eMC - conformity was demonstrated by meeting the                     
following standards:

BS EN 55014-2: 2015: Electromagnetic Compatibility - 
Requirements for Household Appliances, Electric Tools and 
Similar Apparatus - Part 1: Emission

BS EN 55014-1: 2017: Electromagnetic Compatibility - 
Requirements for Household Appliances, Electric Tools 
and Similar Apparatus - Part 2: Immunity - Product Family 
Standard

BS EN 61000-3-2: 2014: Electromagnetic Compatibility (EMC) 
Part 3-2: Limits - Limits for Harmonic Current Emissions 
(equipment input current <16 A per phase)

BS EN 61000-3-3: 2013: Electromagnetic Compatibility (EMC) 
Part 3-3: Limits - Limitation of Voltage Changes, Voltage 
Fluctuations and Flicker in Public Low-voltage Supply             
Systems (equipment with rated current <16 A per phase and 
not subject to conditional connection)

2

saFety

The installer should be aware of his/her responsibilities 
under the current, local Health and Safety at Work Act. The 
interests of safety are best served if the boiler is installed 
and commissioned by a competent, qualified engineer, 
preferably OFTEC trained and registered. A Building Notice 
may be required in England and Wales and other parts of the 
United Kingdom.

Under the Consumer Protection Act 1987 (UK), section 6 of 
the Health and Safety Act 1974 (UK) and the Safety, Health 
and  Welfare  at  Work  Act  2005  (ROI),  we  are  required  to           
provide information on substances hazardous to health.

insulation anD seals
Ceramic Fibre, Alumino - Silicone Fibre material are used for 
boards, ropes and gaskets. Known hazards are that people 
may suffer reddening and itching of the skin. Fibre entering 
the eye will cause foreign body irritation. It may also cause 
irritation to the respiratory tract.

Precautions should be taken by people with a history of 
skin complaints or who may be particularly susceptible to 
irritation. High dust levels are only likely to arise following 
harsh abrasion. Suitable personal protective equipment 
should be worn where appropriate.

generally, normal handling and use will not give discomfort. 
Follow  good  hygiene  practices,  wash  hands  before                          
consuming food, drink or using the toilet.

First Aid - medical attention should be sought following eye 
contact or prolonged reddening of the skin.

The small quantities of adhesives and sealants used in the 
product are cured. They present no known hazards when 
used in the manner for which they are intended.

Fuel sPillage

1.  Switch off all electrical and other ignition sources.

2.  Remove all contaminated clothing to safeguard against 

fire risk and skin damage. Wash affected skin thoroughly 

with soap and water and remove clothing to a safe well 

ventilated area and allow to air before cleaning.

3.  Contain  and  smother  the  spill  using  sand  or  other           

suitable  oil  absorbent  media  or  non-combustible             

material.

4.  Do not allow fuel to escape into drains or water courses. If 

this happens, contact the relevant authorities in your area 

(Ireland).

5.  Consult local authority about disposal of contaminated 

soil.

saFety

Safe use of Kerosene. These fuels give off a flammable 
vapour when heated moderately. Vapour ignites easily, burns 
intensely and may cause explosion. The vapour can follow 
along at ground level for considerable distances from open 
containers and spillages collecting as an explosive mixture in 
drains, cellars, etc.

Fuels remove natural oils and fats from the skin and this may 
cause irritation and cracking of skin. Barrier cream containing 
lanolin is highly recommended together with good personal 
hygiene and where necessary appropriate persona protection 
equipment (P.P.E.).

gas  oil  may  also  cause  irreversible  damage  to  health  on            
prolonged or repeated skin contact.

Always store fuels in a properly constructed and labelled 
tank. Always handle fuel in open air or well ventilated space 
away from sources of ignition and refrain from smoking.

Always drain fuel using a proper fuel retriever, funnel or 
mechanical siphon. Never apply heat to a fuel tank, container 
or pipework. Never siphon fuel through tube by mouth.

Avoid inhaling fuel vapour as this can cause light headedness 
and seriously impair judgement.

FiRst aiD

If fuel is accidentally swallowed:

* Seek medical attention immediately.

Do NOT induce vomiting.

If fuel is splashed into eyes:

* Wash out with running water for at least ten

minutes and seek medical attention.

safety -  conformity was demonstrated by meeting the             
following standards:

BS EN 60335-1: 2012 + A13: 2017: Household and Similar  
Electrical Appliances - Safety - Part 1: general Requirements

BS EN 60335-2-102: 2006 + A2: 2016: Household and 
Similar Electrical Appliances - Safety - Part 2-102: Particular 
Requirements for gas, Oil and Solid-fuel Burning Appliances 
having Electrical Connections

Содержание Envirogreen Combi HE

Страница 1: ...the householder once installation is complete Combi HE Combipac HE Slimline Combi HEATING SOLUTIONS ENVIRONMENT INNOVATION TECHNOLOGY Technical Manual Condensing BoileR C o m b i H E C o m b i p a c H...

Страница 2: ......

Страница 3: ...nd efficiency of all domestic central heating oil boilers Our boilers and burners are supplied as matched units Page 1 Safety 2 2 Standards Regulations 3 2 1 Condensate Disposal 4 2 2 Flue Regulations...

Страница 4: ...ht following eye contact or prolonged reddening of the skin The small quantities of adhesives and sealants used in the product are cured They present no known hazards when used in the manner for which...

Страница 5: ...Building Regulations To ensure the highest standards of installation safety it is important that the boiler be installed in compliance with the following regulations where applicable It is the respon...

Страница 6: ...r in an unheated garage should not exceed 3 meters and Should be lagged with water proof insulation to prevent freezing Boiler Sealed Condensate Drain Discharge Pipe 75mm Soak Away Lime Stone Chipping...

Страница 7: ...of the boiler on the base fixed to the casing of the boiler or mounted on the wall alongside the boiler Condensate pump wired in to come on with burner Inlet connected to condensate trap at base of bo...

Страница 8: ...1 STANDARDS REGULATIONS Condensate Disposal Condensate Trap Fitting 1 Push washer into trap socket and screw trap onto boiler socket 2 Push flexible pipe onto trap socket 3 Final assembly Washer S S...

Страница 9: ...Q R Pressure Jet Location Appliance Burner Type Condensing UK ROI NI A Directly below an opening airbrick opening window etc 1000mm 600mm B Horizontally to an opening airbrick opening window etc 1000m...

Страница 10: ...ved for low level flue and low level balanced flue discharge when tested to BS EN 303 1 5 Terminating positions must be at least 1 8m distant from a fuel storage tank unless a wall with at least 30 mi...

Страница 11: ...disperse vapours 3 The effect of the moisture generated must be considered in relation to the possible corrosion of metal parts it might reach and to the possible formation of ice on pathways in freez...

Страница 12: ...ate System 35 flexible liner suitable for condensing applications System 35 adaptor 500mm Adjustable length Boiler adaptor Condensing boiler Condensing boiler NOTE All brick chimney constructions must...

Страница 13: ...piers with a waterproof membrane between the piers of the tank Fuel storage tanks should not be sited within 1 8m of boiler flue outlets Do not allow household waste or hot ashes container in vicinity...

Страница 14: ...ause Burner Lockout The boiler is factory fitted with a burner control box lockout safety feature which operates automatically if a fault occurs in the burner operation Should this occur the light on...

Страница 15: ...uate temperature controls to ensure return values are as stated above PLASTIC PIPING The boiler thermostat control and safety system is not designed and must not be relied on to protect plastic pipe f...

Страница 16: ...not allow the unit to exceed 1 bar while filling and a maximum of 2 bar when the radiators are at full operating temperature The automatic air vent will allow air to dispel from the boiler To remove a...

Страница 17: ...ost protection It is also required to operate the post purge function on the burner when applicable If a permanent live supply is not provided the burner will not operate Permanent live Earth Neutral...

Страница 18: ...d flue TOP mark Snorkel 1 Push the flap valve into the balanced flue air intake 2 Ensure that the flap valve is in the correct position 3 Push the snorkel hose over the flap valve and air intake and s...

Страница 19: ...ls may not be sufficient to cope with plume dispersal from a condensing boiler 3 17 3 2 Combi HE Combipac HE INSTALLER GUIDELINES 90 terminal should be tilted up to prevent condensate droping from end...

Страница 20: ...760 300 157 61 642 372 344 72 40 676 47 Model Envirogreen output range Weight kg Dimensions mm H W D A C E F G I J K M N Envirogreen Combipac HE 12 20kW 200 945 720 625 795 180 95 691 285 351 133 34...

Страница 21: ...1 Heat deflector ACC000HTD ACC000HTD ACC000HTD 12 1 Air hose ACC000SSH ACC000SSH ACC000SSH 13 1 Flap valve ACC000FLP ACC000FLP ACC000FLP 14 1 Control panel ACP001CCE ACP001CCE ACP001CCE 15 1 Casing r...

Страница 22: ...1 1 Heat deflector ACC000HTD ACC000HTD ACC000HTD 12 1 Flap valve adapter ACC000FVA ACC000FVA ACC000FVA 13 1 Flap valve ACCOOOFLP ACCOOOFLP ACCOOOFLP 14 1 Control panel ACP001CCP ACP001CCP ACP001CCP 15...

Страница 23: ...ue Assembly 125 5 mm dia 125 5 mm dia 125 5 mm dia Max Low Level Flue Length 1 5m 1 5m 1 5m Max High Level Balanced Flue Length 6m 6m 6m Heating System Sealed Fit in accordance with BS 7074 Part 1 BS...

Страница 24: ...perates automatically if a fault occurs in the burner operation Should this occur the light on the front of the burner will illuminate Press the reset button a maximum of two times If the boiler fails...

Страница 25: ...ufacturer for their instruction on how to ensure their product never overheats Our boiler control and safety high limit thermostats are not designed to fulfil this function Firebird accepts no respons...

Страница 26: ...ith a 5A fuse This appliance must be earthed A qualified electrician must carry out all electric wiring in accordance with current ETCI IET Regulations and any local regulations which may apply The bo...

Страница 27: ...nced flue TOP mark Snorkel 1 Push the flap valve into the balanced flue air intake 2 Ensure that the flap valve is in the correct position 3 Push the snorkel hose over the flap valve and air intake an...

Страница 28: ...760 147 325 80 Envirogreen Slimline Combi 20 26kW 168 855 520 600 760 147 325 80 A W H I D A C J Cut out 70x130 mm 770 730 750 780 65 45 80 120 135 Front View Side View Rear View Top View Central heat...

Страница 29: ...ose ACC000FLX ACC000FLX 10 1 Stat pocket ACC001PKT ACC001PKT 11 1 Heat deflector ACC000HTD ACC000HTD 12 1 Air hose ACC000SSH ACC000SSH 13 1 Flap valve ACC000FLP ACC000FLP 14 1 Control panel ACP001CSL...

Страница 30: ...125 5 mm dia Max Low Level Flue Length 1 5m 1 5m Max High Level Balanced Flue Length 6m 6m Heating System Sealed Fit in accordance with BS 7074 Part 1 BS 5449 OFTEC standards and all other relevant le...

Страница 31: ...that the boiler is properly commissioned when first used u The boiler should be commissioned by a competent qualified engineer preferably OFTEC registered and familiar with Firebird products u The ins...

Страница 32: ...es including the tubular baffles in the condensing section and clean them 2 Remove the condensate trap and clean it place a tray under the connection for the trap Vacuum out any loose debris from the...