Temperature at which the boiler cooling will be activated
Parameter
No.
Factory
set-up
Description
06
65
Boiler temperature at which boiler pump (Laddomat) will
be activated
07
250
Maximum flue gases temperature permitted
08
85
Flue gases temperature level at which the burning
process stops when glow function is not activated
09
115
Flue gases temperature level at which the burning
process stops when glow function is activated
10
120
Boiler warming up period (minutes).
If combustion is not successful after this time, i.e. min flue
gas temperature is not achieved, then the boiler is
deactivated and the FUEL light goes on.
11
95
Maximum lower accumulator temperature
12
5
Minimal upper temperature difference between the first
accumulator and the room temperature in order to enable
the heating pump