background image

 
9 servicing instructions 
 

The stove is fitted with a pilot light and flame sensing device 
which is also an oxygen depletion sensor (O.D.S)  

 
This system is not adjustable and must not be put out of action. 
If any parts of this system require replacement only original 
manufacturers parts must be used. 
 
(i) The following servicing procedure should be carried out 
regularly and only by a qualified person. 
 
Ensure that the stove is turned off and is cold. 
(ii) Slacken the allen screw securing the stove door. 
(iii) Remove the logs, back board and front log piece in the 
reverse order to that described in 5. POSITIONING THE 
LOGS. 
(iv) Remove any deposition of dirt, lint, etc. carefully from the 
burner flame strip, tray and pilot assembly with a soft brush. 

(v)

 

Due to intense temperatures reached in the fire, 
some surface cracks may appear on the ceramic 
components. This is quite normal and will not affect 
the safe operation of the stove. 

(vi)

 

Replace the front log piece, back board and logs as 
described in 5. POSITIONING THE LOGS 

(vii)

 

Close the stove door and secure with an Allen key 

(viii)

 

Check the supply pressure as described in 
6.COMMISIONING THE STOVE. 

(ix)

 

Ensure correct operation of the flue as described in 
7. CHECK FOR SPILLAGE. 

 

 

Содержание FB1 Gas

Страница 1: ...Installation and Servicing Instructions FB1 Gas GB IE Unit 16 Upper Mills Canalside Slaithwaite Huddersfield HD7 5HA UK...

Страница 2: ...Countries AT CH DK ES FI GB IE IT PT SE NL BE CH ES FR GB IE IT PT Gas Connection 8mm Tube 8mm Tube 8mm Tube 2 Important Notes This stove is a fuel effect radiant convector Before installation ensure...

Страница 3: ...Regulations The stove is fitted with a spillage combustion monitoring safety device O D S This system is not adjustable and must not be put out of action If any parts of the spillage monitoring syste...

Страница 4: ...tances must be extended to a minimum clearance of 500mm from any combustible material ii Hearth The stove must stand on a fireproof hearth made of non combustible material of minimum thickness 12mm an...

Страница 5: ...e flue v VENTILATION Ventilation should be in accordance with National Regulations In the United Kingdom purpose provided ventilation is not normally required except in new build houses vi GAS CONNECT...

Страница 6: ...5 positioning of the logs Slacken the Allen screw using an Allen key securing the stove door and open the door as shown below...

Страница 7: ...Close the stove door and secure with an Allen key Under no circumstances should the stove be operated with the door open without the door attached or the glass damaged...

Страница 8: ...counter clockwise to activate piezo continue to hold down for ten seconds after pilot burner has been lit If pilot does not light steps 1 and 2 can be repeated immediately Upon lighting release knob a...

Страница 9: ...ning knob B To Turn Off Gas to Stove Turn knob A clockwise until reaching stop In this position only pilot gas flows To shut off the valve completely press down slightly and continue to turn clockwise...

Страница 10: ...t For the handset to function correctly the transmitter must remain within the range of the receiver The transmitter should not be used in very close proximity of the receiver less than 1 metre 3 ft a...

Страница 11: ...m Point out the explanation of this system is in the Users Instructions Advise that if the monitoring system repeatedly shuts off the stove it should be switched off and a specialist consulted Advise...

Страница 12: ...e the logs back board and front log piece in the reverse order to that described in 5 POSITIONING THE LOGS iv Remove any deposition of dirt lint etc carefully from the burner flame strip tray and pilo...