9 servicing instructions
The stove is fitted with a pilot light and flame sensing device
which is also an oxygen depletion sensor (O.D.S)
This system is not adjustable and must not be put out of action.
If any parts of this system require replacement only original
manufacturers parts must be used.
(i) The following servicing procedure should be carried out
regularly and only by a qualified person.
Ensure that the stove is turned off and is cold.
(ii) Slacken the allen screw securing the stove door.
(iii) Remove the logs, back board and front log piece in the
reverse order to that described in 5. POSITIONING THE
LOGS.
(iv) Remove any deposition of dirt, lint, etc. carefully from the
burner flame strip, tray and pilot assembly with a soft brush.
(v)
Due to intense temperatures reached in the fire,
some surface cracks may appear on the ceramic
components. This is quite normal and will not affect
the safe operation of the stove.
(vi)
Replace the front log piece, back board and logs as
described in 5. POSITIONING THE LOGS
(vii)
Close the stove door and secure with an Allen key
(viii)
Check the supply pressure as described in
6.COMMISIONING THE STOVE.
(ix)
Ensure correct operation of the flue as described in
7. CHECK FOR SPILLAGE.