9
EN
WIRELESS SET-UP
How to ‘learn-in’ a wireless device to the relay:
Install unit as described earlier (see ‘Installation’).
Install the smoke, heat or CO alarm in its appropriate
location.
1.
Using a ballpoint pen briefly push and release the
‘learn button’ marked “LRN” on the front section of
the relay. The ‘learn’ LED will illuminate “Blue” once
for 5 seconds.
2. While the LED is on, briefly press the test button on
the alarm to wirelessly interlink the two. The alarm
will give an audible sound consisting of two cycles
of three loud beeps.
3. The “Blue” ‘learn’ LED of the relay unit will flash
repeatedly to indicate that it has been ‘learned-
in’ successfully. If the test button is not pressed
quickly enough, the ‘learn-in’ process will fail. If
this happens, repeat the process.
Your relay unit counts as one unit within the network.
The network cannot exceed 50 units in size including
the relay unit.
To complete the installation, fit the relay unit cover
using the screws provided.
Unlearning the relay from the network:
NOTE: Ensure to disconnect mains power prior to
removing lid and unscrewing unit from its installation
position.