12
PRODUCT INDICATORS
Mode
Green LED
Red LED
Amber LED
Chirp
Normal Operation
Flashes once per
minute
-
-
-
Alarm
-
Flashes once every
five seconds
-
Four audible ‘chirps’
repeated
Low battery / End of
sensor life
-
-
Flashes once per
minute
Chirps once per
minute at the same
time as the amber
LED flashes
Sensor fault
-
-
Double flashes
Chirps at a different
time to the amber
LED flashes
IMPORTANT:
The selected power pack was chosen to provide power beyond the lifetime of the product, in
particular the sensor (under normal operating conditions). The sensor life is 10 years. For this reason, the alarm
should be replaced after 10 years from the date of installation.
The Alarm LED (red) is flashing
If the red LED is flashing every second and the alarm is sounding, a
carbon monoxide leak has been detected. Keep calm and open the
doors and windows to ventilate the property. Stop using all fuel burning
appliances and ensure, if possible, that they are turned off. Evacuate the
property leaving the doors and windows open. Contact your gas or other
fuel supplier on their emergency number.
The Fault LED (amber) is
illuminated and the alarm is
making a “chirping” sound.
If the amber LED is flashing once per minute and at around the same
time as the chirp, this indicates a low battery condition and the alarm
should be replaced as soon as possible and certainly within 30 days. If this
fault occurs at night, when it may be inconvenient to replace your alarm,
please refer to the 'Sleep Easy
TM
' feature. If the amber LED is flashing once
per minute but at a different time to the chirp, this indicates a fault and the
alarm should be replaced immediately.