7
HOW TO INSTALL YOUR
DETECTOR
NOTE:
This apparatus should be installed
by a competent person who feels able to
install it according to the instructions.
Firstly write the installation date on
your detector in the area provided. We
recommend that your detector is installed on
the wall.
To mount on a wall or ceiling:
Please ensure that you use the screws
provided, as they were chosen specifically
for use with this product. Use the template
below for guidance on marking hole
positions. Drill holes into the wall. Insert the
plastic wall plugs. Screw in the screws. Ensure
screws are protruding from the wall by 3mm
to allow detector to slot onto screws.
To place on a shelf:
The base of the detector has been designed
to allow it to stand freely on a shelf.
WARNING:
When placing on a shelf,
please adhere to the same positional
recommendations as described on pages 5
and 6.
65mm
Drill hole spacing
Caravans
Caravans may have additional risks of carbon
monoxide ingress through air vents due
to the nearby presence of other vehicles,
engines, generators or barbecues, however
this does not change the basic guidance
on location of the alarm. Caravans should
be fitted with an alarm in the same room
as any combustion appliance(s), located
in accordance with previous advice in this
section. If the caravan has a single living
space which incorporates the sleeping
accommodation, it can be considered to
be equivalent to a bedsit, and a single
alarm is sufficient. However, any sleeping
accommodation which is in a separate room
from the combustion appliance(s) should
also contain an alarm, located in accordance
with previous advice in this section.
It is not always possible to find an optimum
location for an apparatus, for example, a
small caravan may not have suitable vertical
surfaces available. Nevertheless, when
fitting an apparatus in such situations, the
two most important considerations when
selecting an appropriate location are:
•
Not mounting the apparatus directly
above a source of heat or steam; and
•
Mounting the apparatus at a distance
of 1 – 3 m from the nearest edge of the
potential source.