background image

15

  If installing in a caravan there maybe other 

substances present, that may not normally 

be found in the home, that could effect 

the reliability of the CO alarm. Avoid using 

the following in close proximity to the 

alarm; oils, cleaning fluids, polishes, paints 

and greases.

   Move the detector to a safe location and 

store in a plastic bag before painting, 

wall papering, or performing any other 

activities using substances that emit 

strong fumes. Remember to remove it 

from the bag and replace the detector 

when these activities are finished.

Failure of any test should be reported to the 

Technical  Support  Team  (see  page  21  for 

contact details).
Do  not  attempt  to  repair  your  CO  detector. 

Do not remove any screws or open the main 

casing  of  your  detector.  Any  attempt  to  do 

so may cause malfunction and will invalidate 

the warranty.

WHAT TO DO IN THE 

EVENT OF AN ALARM

WARNING:

  A  loud  alarm  is  a  warning 

that  unusually  high  and  potentially 

lethal levels of carbon monoxide are present. 

Never  ignore  this  alarm,  further  exposure 

can be fatal. Immediately check residents for 

symptoms  of  carbon  monoxide  poisoning, 

and contact the proper authorities to resolve 

all CO problems. NEVER IGNORE ANY ALARM.
Please  carefully  review  this  owner’s  manual 

to ensure that you know what actions to take 

in the event of an alarm.

What to do during an alarm

  Keep calm and open the doors and 

windows to ventilate the property.

  Stop using all fuel burning appliances and 

ensure, if possible, that they are turned 

off.

  Evacuate the property leaving the doors 

and windows open.

  Contact your gas or other fuel supplier 

on their emergency number; keep the 

number in a prominent place.

Write your fuel supplier’s emergency number 

here (see page 17 for more useful numbers):

____________________________________

  Do not re-enter the property until the 

alarm has stopped. When exposed to 

Содержание CO-9D

Страница 1: ...DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM Includes all colour variants CO 9D User Manual Please read me as I could save your life Please retain this user manual for future reference ...

Страница 2: ......

Страница 3: ...R TEST UNDERSTANDING THE PRODUCT S INDICATORS MAINTAINING TESTING YOUR DETECTOR WHAT TO DO IN THE EVENT OF AN ALARM USEFUL NUMBERS TECHNICAL INFORMATION DISPOSAL 7 YEAR WARRANTY RETURNS PRODUCT RANGE NOTES DISABLING TAB STORAGE PAGE 2 2 3 5 7 8 9 9 11 12 14 15 17 18 19 20 21 21 22 CONTENTS Note This User Manual is also available in large text and other formats Please call 0800 141 2561 for further...

Страница 4: ...eAngel manufactures some of the most technologically advanced carbon monoxide detectors in the world FEATURES An advanced electrochemical sensor designed to accurately measure low levels of carbon monoxide CO providing an early warning of toxic CO levels in your home Detects carbon monoxide continuously Resistant to false alarms caused by normal household contaminants Sounds a loud 85dB alarm at 1...

Страница 5: ...ache nausea vomiting fatigue often described as flu like symptoms Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate Extreme Exposure Unconsciousness convulsions cardiorespiratory failure death Your FireAngel CO detector monitors the level of CO as parts per million ppm in the atmosphere surrounding the detector 35ppm The maximum allowable concentration for continuous e...

Страница 6: ...or this and other reasons do not use this carbon monoxide detector on an intermittent basis or as a portable detector for trying to trace one source of the spillage of combustion products from fuel burning appliances or from chimneys Do not IGNORE ANY WARNING FROM YOUR CO DETECTOR Burn charcoal inside your home caravan tent or cabin Install convert or service fuel burning appliances without proper...

Страница 7: ...ent in other areas In which room should the detector be installed Ideally an apparatus should be installed in every room containing a fuel burning appliance Additional apparatus may be installed to ensure that adequate warning is given for occupants in other rooms by locating apparatus in Remote rooms in which the occupant s spend considerable time whilst awake and from which they may not be able ...

Страница 8: ...ocated at a height greater than the height of any door or window c it should be at least 150mm from the ceiling If the apparatus is located on the ceiling a it should be at least 300mm from any wall and any ceiling obstruction e g light fittings Apparatus located in sleeping rooms and in rooms remote from a fuel burning appliance Apparatus located in sleeping rooms or located in rooms remote from ...

Страница 9: ...on monoxide ingress through air vents due to the nearby presence of other vehicles engines generators or barbecues however this does not change the basic guidance on location of the alarm Caravans should be fitted with an alarm in the same room as any combustion appliance s located in accordance with previous advice in this section If the caravan has a single living space which incorporates the sl...

Страница 10: ...nce every minute c Test the sounder power pack and circuitry by pushing the centre of the Test Mode button briefly to confirm that the detector is operating properly The sounder will sound as soon as the button is pressed and the Alarm LED will illuminate red indicating that the sounder is working and the power pack is providing power to the unit You ll notice that the display will switch to tempe...

Страница 11: ...ng out a thin metal paper clip into a U shape OPERATING FEATURES Your FireAngel detector offers many features which set it apart from other CO detectors on the market today Standby mode The alarm can display two views when in normal standby mode the current level of CO or the current room temperature in degrees centigrade ºC When the alarm is showing the current CO Level you will see something sim...

Страница 12: ...nd circuitry test Pressing the Test Mode button will also test the power pack sounder and circuitry of the alarm The unit will sound and the alarm LED below will illuminate red You should perform this test once per week Peak Level Reading feature The alarm will record the highest reading of CO that is has detected in the last 4 weeks This information is useful if your alarm has sounded so you can ...

Страница 13: ...ource of CO Step 3 Light an incense stick or cigarette using a match or lighter Extinguish the lighter or put out the match and place it into a dish of water Step 4 Hold the incense stick or burning cigarette 15cm 6 inches below the detector so that the smoke goes into the holes at the bottom of the detector As the smoke gets into the alarm the display will show the amount of CO being detected Whe...

Страница 14: ...291 1 2010 so the alarm will only sound when it has detected CO for a prescribed length of time the higher the level of CO the quicker the alarm must sound However with FireAngel s CO 9D there is an early visual warning that CO is present When CO is first detected the alarm indicates it s presence by displaying the level on the screen in parts per million ppm If CO continues to be present addition...

Страница 15: ...ppear as the CO in the sensor clears Alarm in absence If the Peak level reading symbol is showing on the screen but there is no full alarm sound and you are not pressing the test button then your detector is warning that it has detected Carbon Monoxide in your absence Immediately vacate the premises and seek medical attention for anyone suffering the effects of CO poisoning headache nausea see pag...

Страница 16: ... to potentially hazardous CO concentrations in your home when maintained properly To keep your FireAngel detector in proper working order and to ensure that the sensor will last for the lifetime of the product it is recommended that you Test the sounder power pack and circuitry of your detector at least once per week by pressing the Test Mode button briefly see page 10 Perform the Sensor Test annu...

Страница 17: ...nty WHAT TO DO IN THE EVENT OF AN ALARM WARNING A loud alarm is a warning that unusually high and potentially lethal levels of carbon monoxide are present Never ignore this alarm further exposure can be fatal Immediately check residents for symptoms of carbon monoxide poisoning and contact the proper authorities to resolve all CO problems NEVER IGNORE ANY ALARM Please carefully review this owner s...

Страница 18: ...arbon monoxide detected Get medical help immediately for anyone suffering the effects of carbon monoxide poisoning headache nausea and advise that carbon monoxide poisoning is suspected Do not use the appliance again until it has been checked by an expert In the case of gas appliances the engineer must be registered ...

Страница 19: ...olid fuel appliances HETAS Trade association for solid fuel engineers OFTEC Trade association for Oil Fired Appliance engineers NACS National Association of Chimney Sweeps IPHE Institute of Plumbing and Heating Engineers 0800 111 999 24 Hours 0800 408 5500 0845 601 4406 0845 223 3033 0845 658 5080 01785 811 732 01708 472 791 ...

Страница 20: ...Humidity Range 30 90 RH Weight 120 grams 4 23oz Certified to EN 50291 1 2010 EN 50291 2 2010 This FireAngel carbon monoxide detector is designed to continuously monitor for CO Its response times meet the requirements of European standard EN 50291 1 2010 The alarm will sound Between 60 and 90 minutes when exposed to 50ppm of CO Between 10 and 40 minutes when exposed to 100ppm of CO Within 3 minutes...

Страница 21: ...ack in to the socket located on the underside of the detector see page 9 If the disabling tab is no longer available then the clip can be replicated by opening out a thin metal paper clip into a U shape WARNING DO NOT ATTEMPT TO OPEN DO NOT BURN WARNING APPARATUS CONFORMING TO THIS STANDARD MAY NOT PROTECT PEOPLE WHO ARE AT SPECIAL RISK FROM CARBON MONOXIDE EXPOSURE BY REASON OF AGE PREGNANCY OR M...

Страница 22: ...haser from the date of original retail purchase and is not transferable Proof of purchase is required This warranty does not cover damage resulting from accident misuse disassembly abuse or lack of reasonable care of the product or applications not in accordance with the user manual It does not cover events and conditions outside of Sprue Safety Products Ltd s control such as Acts of God fire seve...

Страница 23: ...r the phone this is to prevent unnecessary returns that take a longer time to process Alternatively e mail technicalsupport fireangel co uk If there is a fault that we are unable to resolve then our technical support team member will provide you with a returns authority number so that your product can be returned for testing To return your FireAngel smoke alarm under warranty send it suitably pack...

Страница 24: ...22 NOTES STORE DISABLING TAB HERE Tape disabling tab here for future use ...

Страница 25: ...23 NOTES ...

Страница 26: ...24 NOTES ...

Страница 27: ......

Страница 28: ...800 141 2561 EIRE dial 1 800 523171 Email technicalsupport fireangel co uk Web www fireangel co uk CO 9D GN0637R6 EN 50291 1 2010 EN 50291 2 2010 KM 551504 Sprue Safety Products Ltd Vanguard Centre Sir William Lyons Road Coventry CV4 7EZ UK A Sprue Safety Products Brand ...

Отзывы: