CAUTION: This service is to be completed only by an authorized gas appliance installer. Do
not attempt this conversion on your own as there is risk of serious injury or death.
To The Authorized Gas Appliance Installer,
All TriParo Gas Log Fire Pits are shipped from the factory equipped to burn on liquid propa ne fuel. Enclosed with this kit is
a natural gas conversion kit to allow the owner to convert and operate this unit on natural gas. To perform this conversion,
please follow the directions below and to the local regulation standards in your area.
STEP # 1:
Make sure unit is not in operation and is cool enough to perform this service. Shut off and disconnect propane
fuel source at the regulator end.
STEP # 2:
Carefully remove the storage cover, lava rocks and fire logs. Turn unit over to access hose connec tions
underneath.
STEP # 3:
While holding the propane orifice in place with a wrench, unscrew brass fitting on fuel inlet hose. Unscrew
propane orifice and remove, along with the protective screening over the air inlet.
STEP # 4:
Using the new protective screen and air inlet control cover, insert it over the fuel inlet hose leading into the
base of the burner. Turn it slightly to allow a controlled amount of air flow through the screen and into the fuel supply tube.
Flame should have good retention.
STEP # 5:
Refer to photo below for proper placement of parts. The washer should insert next to the protective screen
cover, then the spring is to be aligned with the hole and finally the natural gas orifice is to be threaded into the end of the
fuel inlet leading into the burner. Once tight the other brass fitting connection can be made from the fuel line fitted
between the valve and the orifice.
STEP # 6:
Connect natural gas supply hose, (not included with kit), from supply source. Test for leaks.
STEP # 7:
Once the conversion is completed and leak tested, reload the fit pit with the lava rocks and fire logs. Test the
unit while in place and verify it works properly. If flame from burner is not properly adjusted you can adjust air intake by
turning the protective screen cover and air intake sleeve on the fuel supply tube.
Fire Stone Home Products 12400 Portland Ave S., Suite 195, Burnsville, MN 55337
Fuel Supply End
Burner End
Direction of Fuel Flow
Natural Gas
Orifice
Tension
Spring
Washer
Protective Screen & Air
Intake Sleeve