WARNING
Make sure all appliance components are completely cooled and gas supply is turned off and
removed
from the appliance prior to performing the conversion.
WARNING
Make sure all control knobs and cylinder valves are in OFF position before converting.
tanks and their use are covered elsewhere in this manual). If a Natural Gas connection is available, the user may wish to
change the gas delivery system to the more permanent Natural Gas Supply.
This appliance is certified for use with either Liquid Propane (LP Gas) or Natural Gas and comes complete with the
necessary parts to convert the appliance for use with Natural Gas. A Natural Gas hose and regulator are also required and
are sold separately. The conversion valves allow the use of Natural Gas without replacing the burners or entire valve
system.
The process of converting the burner from Propane to Natural Gas is relatively simple and can be accomplished by any handy
homeowner. We recommend, however, that a qualified gas technician do the conversion. Your warranty may be voided if
the conversion is improperly completed. Please retain the parts supplied with the appliance and these instructions so the
technician can do the conversion.
Orifice Chart
The different burner valves in this appliance have different BTU ratings. The holes in the orifices are drilled to different sizes so as
to allow the proper amount of gas to flow through them. Please note the chart below to give an easy reference for the various
orifice opening sizes for the different valves in the appliance.
Propane (Pressure 11”)
NG (Pressure 7”)
Input Rate (BTU/h)
Input Rate (BTU/h)
2.
3
mm
55
,000
3.78
mm
55
,000
NG Hose and Regulator Conversion
Tools Required:
•
Adjustable Wrench
(2)
CONVERSION
TO