INSTALLATION
: LPG
(TSYFHYZXKTWFXXNXYFSHJa\\\GFQPJSJMTRJHTR
IF USING UNIT WITH AN LPG FUEL SOURCE:
Connect hose and regulator to cylinder. The propane gas and
cylinder are sold separately. Use a standard 20 lb propane
cylinder only. Use this fire pit only with a propane vapor
withdrawal supply system. See chapter 5 of the standard storage
and handling of liquefied petroleum gas, ANSI/NFPA 58. Your
local library or fire department should have this book.
Storage of an appliance indoors is permissible only if the
cylinder/gas supply is disconnected and removed from the
appliance. A cylinder must be stored outdoors in a well-
ventilated area out of the reach of children. A disconnected
cylinder must have dust caps tightly installed and must not be
stored in a building, garage, or any other enclosed area. The
maximum inlet gas supply pressure: 250 PSI. The minimum inlet
gas supply pressure: 5 PSI.
The minimum hourly of 10,000 BTU is required input rating for a
fire pit for automatic operation at ratings less than full input
rating. The pressure regulator and hose assembly supplied with
the appliance must be used.
Installation must conform with local codes, or in the absence of
local codes, with national fuel gas code, ANSI Z223.1/NFPA54,
natural gas and propane installation Code, CSA B149.1, or
propane storage and handling code, B149.2.
5