Specifications 

Model: 

      60803 

Voltage: 

      120 

volts 

Amps: 

      12.5 

amps 

Wattage:      1500 

watts 

Lamp 

Type: 

     Quartz 

Halogen 

Minimum Operational Height:  

7 ft., 11 in. (95 in.) 

Assembled 

Weight: 

   69 

lbs. 

Head Unit Dimensions:   

 

25.6” x 21.6” x 18.1” 

Heater Assembled Dimensions: 

15.75” diameter base, 95” height 

 

Storage 
* Always UNPLUG the unit when not in use. 

Once the head unit has completely cooled, store the heater with the protective vinyl cover on the 

head unit. 
* When heater is not in use for an extended period of time, store in a covered location that is dry and 
out of the weather. Make sure the heater is stored in a location that is out of the way of people and pets 
that may accidentally knock the heater over or damage the appliance. Before storing the heater, make 
sure the electrical cord is coiled and out of the way. 
* When storing, 

ALWAYS

 lower the telescopic pole to its lowest level. This will make it easier to 

store and reduce the risk of any accidental tipping over of the heater. 
 

Maintenance 

Your Infrared Heating System is virtually maintenance free! A minute to wipe down exposed surfaces 
is all it takes to maintain your heater. 
* Head unit and shield: Use a non-abrasive cleaner and a soft cloth to wipe off debris and dirt from the 
exposed surfaces. 

NEVER spray liquids or cleaners into the housing area where the halogen lamp 

is located.

 Do not try to disassemble of clean the inner cavity where the halogen lamp is located. For 

any maintenance on the head unit, please call the toll free customer service hotline. 
* Telescopic pole and curved arm components: These can easily be wiped clean using a non-abrasive 
cleaner and a soft cloth. 
* Base with wheel assembly: Use non-abrasive cleaner and a soft cloth. Any scratches, chips or rust 
spots can be touched up using an exterior matte finish paint. 

 

13 

Содержание 60803

Страница 1: ...GS AND OPERATIONAL INSTRUCTIONS CONTAINED IN THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND OR PERSONAL INJURY For Residential Use Only Important Notice Do not return to place of purchase Please...

Страница 2: ...of Fire There is always a risk of fire when working with a heater Keep it away from flammable liquids and any material that could easily catch fire 2 Risk of Fire If the heater falls this unit might s...

Страница 3: ...Bracket 15 5 foot 14 AWG grounded electrical cord 2 Mounting Bracket attaches head unit to telescopic pole 3 Upper support tube section for telescopic body 4 Telescopic Body includes 2 sections 4 1 a...

Страница 4: ...hen remove plug from electrical outlet 10 Connect to properly grounded outlets only 11 Do not insert or allow foreign objects to enter any ventilation or exhaust opening doing so may cause an electric...

Страница 5: ...clean level preferably carpeted location A flat piece of cardboard will also work for assembly Unpack and identify all components listed on page 3 of this manual and lay them out on the carpeted floo...

Страница 6: ...ket Part 2 to head unit Part 1 as shown in Figure 3 STEP 4 Align tilt switch black box on head unit Part 1 to threaded holes on Mounting bracket Part 2 and insert M4 10 Round head screws Hardware C wi...

Страница 7: ...res 5 and 6 STEP 6 Attach Top cover finishing piece Part 6 to Upper support tube section Part 3 with 4 M6 12 Oval head screws Hardware A as shown in Figure 7 STEP 7 Attach L shaped bracket Part 8 to U...

Страница 8: ...gh assembled Upper support tube section Part 3 as show in Figure 9 STEP 9 Attach assembled Upper support tube section Part 3 to Mounting bracket Part 2 with 4 M6 12 Oval head screws Hardware A as show...

Страница 9: ...large round hole at the bottom of the section see Figure 12 and slide section 4 1 down into section 4 2 until you can see the small machined hole from section 4 2 through the large round hole at the b...

Страница 10: ...y Part 4 1 as shown in Figure 14 STEP 12 Attach wheel assembly to base assembly with 3 M8 16 Hexagon screws Hardware I Mount Support collar flange Part 9 to Base assembly with wheels Part 10 as shown...

Страница 11: ...Base assembly Part 10 and out of the hole on the Base assembly as shown in Figure 16 STEP 14 Carefully lift assembled pole and head unit and insert lower end of pole into Support collar Part 9 as show...

Страница 12: ...and then push in clamp levers to secure DO NOT over tighten tension knobs There should only be a moderate amount of tension to maintain the telescopic position of your heater Step 1 Before turning on...

Страница 13: ...way When storing ALWAYS lower the telescopic pole to its lowest level This will make it easier to store and reduce the risk of any accidental tipping over of the heater Maintenance Your Infrared Heat...

Страница 14: ...emove the left and right front air vent panels and protective wire grill 3 Note the position of end clips on vent panel They must be aligned as close to the end connectors of lamp tube as possible whe...

Страница 15: ...le slips down Tighten black tension knobs on clamp collars Telescopic pole is unsteady Tighten screws on support collar at base Telescopic pole will not adjust Electrical cord may be kinked Gently pul...

Страница 16: ...N THIS MANUAL CAN RESULT IN SEVERE PROPERTY DAMAGE AND OR PERSONAL INJURY IN NO EVENT WILL WELL TRAVELED LIVING OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHE...

Отзывы: