Version: March 2019 11
OPERATING INSTRUCTIONS
The WD6 has an integrated flue damper which has two positions
– open and closed.
The flue damper MUST be in the open position when the fire is being used. To set the flue damper
to the open position, simply push it to the rear of the fire.
If the fire is not being used for an extended period (for example, over summer), the flue damper
can be pulled forward to the closed position, which reduces external noises and drafts.
Ongoing maintenance
. It is recommended that the flue be swept every year (some insurance
companies require this), or more often if required.
………………..
TROUBLESHOOTING
Problem
Probable Cause
Action
Smoke coming out the front of the fire
1. Poor quality or damp wood
2. Flue damper is closed
3. Draft flowing into or across fire
4. Flue terminates at poor position
outside (eg. windy part of roof)
5. A nearby extractor fan is sucking
smoke from the fire
1. Change wood
2. Open flue damper
3. Remove source of draft
4. Reposition flue termination
5. Switch off or reposition extractor fan