The WD6 has an integrated flue damper which has two positions 

– open and closed.  

 

 

The flue damper MUST be in the open position when the fire is being used. To set the flue damper 
to the open position, simply push it to the rear of the fire.  

 

 

If the fire is not being used for an extended period (for example, over summer), the flue damper 
can be pulled forward to the closed position, which reduces external noises and drafts. 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Ongoing maintenance

. It is recommended that the flue be swept every year (some insurance 

companies require this), or more often if required.  

 

……………….. 

TROUBLESHOOTING

 

 

Problem

 

 

 

Probable Cause

 

 

Action

 

 
Smoke coming out the front of the fire 
 
 
 
 

 
1.  Poor quality or damp wood 
2.  Flue damper is closed 
3.  Draft flowing into or across fire  
4.  Flue terminates at poor position 

outside (eg. windy part of roof) 

5.  A nearby extractor fan is sucking 

smoke from the fire 

 

 
1.  Change wood 
2.  Open flue damper 
3.  Remove source of draft 
4.  Reposition flue termination 
 
5.  Switch off or reposition extractor fan   
 

 

 

 

 

 

Содержание WD6

Страница 1: ...WD6 Timber Cavity Installation Guide Operating Instructions Warranty...

Страница 2: ...ce become extremely hot during operation and can result in serious injury and burns if touched It is therefore recommended that a fireguard complying with BS 8423 2002 is used in the presence of young...

Страница 3: ...1 Unpack and ensure all components are correct and undamaged Steel firebox Outer cavity box Ashpan AAC panels AAC supporting brackets Flue kit WD6 technical specifications to be read in conjunction wi...

Страница 4: ...dimensions are correct refer to technical specifications Ensure hearth dimensions are correct refer to technical specifications Plan flue path The starting point Timber frame Note Timber lintel to sui...

Страница 5: ...upporting brackets into cavity Fix the AAC supporting brackets into position in accordance with technical specifications example shown Rear brackets have 6 x fixing holes each and the front brackets h...

Страница 6: ...eel supporting brackets Countersink 2 x 5mm 80mm long steel screws per bracket NOTE ensure fixing bolts screws don t extend past and into the base under the AAC supporting brackets 3 Fix hearth AAC pa...

Страница 7: ...nimum of two people slide the firebox and outer cavity box into position 3 Fix the fire box through the AAC panel and into the AAC supporting brackets 2 x 5mm x 120mm long self drilling steel fixings...

Страница 8: ...The inner casing runs into the outer cavity box The outer casing finishes 25mm above the outer cavity box 2 Complete the rest of the flue installation Note The 1600mm wide model has 2 flues 3 Complete...

Страница 9: ...Version March 2019 9 Step 7 Insert ashpan into fire box cavity Insert ashpan into firebox Appliance is now ready for customer specified outer finishes...

Страница 10: ...h 2019 10 Step 8 Show owner how to operate appliance Following the Operating Instructions on the next page show the owner how to operate the baffle If the owner is not available leave this manual by t...

Страница 11: ...position which reduces external noises and drafts Ongoing maintenance It is recommended that the flue be swept every year some insurance companies require this or more often if required TROUBLESHOOTIN...

Страница 12: ...d warping if a firebox outer skin or support frame defect occurs contact The Fire Dept and the defect will be repaired or replaced at our discretion with all costs covered The Fire Dept warrants the S...

Отзывы: