Version: August 2020
10
Flow from the In-Line Fan to termination
In-Line Fan
Casing slip
In-Line Fan assembly details
Step 1:
Connect the flue and outer casing to the appliance
1. Make sure the In-line Fan has adequate access for future maintenance.
2. Run the flue from the appliance to the location of the In-line Fan.
3. Run the outer casing from the appliance to finish 90mm shorter than the flue.
Note
: The outer casing must have the crimped end removed.
Step 2:
Connect the In-Line Fan to the flue and outer casing
1. Fit the Casing slip over the outer casing.
2. Fit the flue over the inlet spigot to the In-Line Fan.
3. Fix the flue to the inlet spigot at the In-Line Fan.
Step 3
Complete the flue installation
1. Slide the casing slip up the outer casing and over the outer casing spigot
at the In-Line Fan.
2. Fix the casing slip to the outer casing and the In-Line fan
3. Complete the flue installation. Refer to appropriate Fire Dept product
specification for fixing details and specific minimum requirements.