Страница 1: ...English English English English TETRA and UHF Compact Repeater User Installation Manual ...

Страница 2: ...I Document History Description Revision Date Issued Preliminary release for early field trials 1 0 August 3 rd 2009 Indicator panel and cabinet modifications 2 0 April 13 th 2010 Software screenshots updated 3 0 August 20 th 2010 ...

Страница 3: ...ftware Hardware and software mentioned in this manual are subjected to continuous development and improvement Consequently there may be minor discrepancies between the information in the manual and the performance and design of the hardware and software Specifications dimensions and other statements mentioned in this manual are subject to change without notice This manual or parts of it may not be...

Страница 4: ... Discharge 1 Disposal of Electric and Electronic Waste 1 2 Product Description 2 Dimensions 3 3 Installation 4 Sitting the repeater 4 Mounting 4 4 Commissioning 8 Connection 8 Starting operation 9 Status Indicators 11 Automatic Gain Control AGC 12 Overload Protection 12 Laboratory Measurements 12 Part 2 SOFTWARE 13 5 Installation 13 6 Overview 19 General Tabsheet 19 Status tabsheet 20 Configuratio...

Страница 5: ...bile communication ETACS Extended Total Access Communication System ETSI European Telecommunications Standard Institute GSM Global System for Mobile communication HW Hardware LED Light Emitting Diode LNA Low Noise Amplifier uplink and downlink MS Mobile Station MS antenna towards the mobile station OMS Operation and Maintenance System OL Overload PA Power Amplifier PCN Personal Communication Netwo...

Страница 6: ...r from all persons R TTE Compliance Statement This equipment complies with the appropriate essential requirements of Article 3 of the R TTE Directive 1999 5 EC Station Ground BTS chassis Repeater feeders donor antenna service antenna s and auxiliary equipment splitters tabs etc are required to be bonded to protective grounding using the bonding stud or screw provided with each unit Electrostatic D...

Страница 7: ...UM 0100 03 09 August 2010 2 2 Product Description ...

Страница 8: ...UM 0100 03 09 August 2010 3 Dimensions ...

Страница 9: ...ining snowing or hailing there must be some kind of permanent or temporary protection This is applicable to gentle rainfall snowfall or hail We extremely recommend not operating the repeater under very bad weather conditions such as Intense rainfall snowfall or hail Storm or high wind Extremely low or high temperature High humidity of the air Mounting 1 Mount the provided bracket Normally the repe...

Страница 10: ...0 03 09 August 2010 5 1 After attaching the bracket hang the repeater Figure 3 2 Screw the cabinet to the bracket Attach repeater s cabinet to the bracket using four M6 x 2 allen screws Release repeater cover ...

Страница 11: ...UM 0100 03 09 August 2010 6 Open repeater cover Place and screw the four M6 x 2 allen screws ...

Страница 12: ...UM 0100 03 09 August 2010 7 Close repeater cover Secure repeater cover ...

Страница 13: ...na TO MOBILE port and donor antenna TO BASE port coaxial cables N type female connectors are used in the repeater 2 Once RF ports of the repeater are properly loaded connect mains to the AC source Electrical installation must provide differential and termo magnetic breaker elements according to electric safety international regulations L N TMB DB ...

Страница 14: ... takes about 20 seconds to run a booting routine After that time repeater is ready to be connected via USB cable to a computer running pFOMS in order to be properly configured See Part 2 Software of this manual to install pFOMS Starting operation 1 Setup desired filter configuration using pFOMS only for programmable band selective and programmable channel selective models For fixed bandwidth repea...

Страница 15: ...UM 0100 03 09 August 2010 10 Figure 5 Figure 5 shows how to set up manual attenuation values ...

Страница 16: ...ble 1 1 Start UP Every time the repeater is plugged to AC mains or auxiliary DC power will start a self diagnosis and booting sequence that lasts around 20 seconds during this time repeater is not available for traffic and the reason is because an automatic antenna isolation control procedure runs in order to detect poor isolation conditions During this time all leds in the front panel will blink ...

Страница 17: ...he maximum composite output power available from the repeater Anyway is a good practice to increase attenuation reducing gain until AGC led turns off this operation releases AGC circuitry dynamic range Also is a good practice to check signals from donor site to ensure that undesired signals are not being amplified by the repeater or even desired signal levels are not excessively high taking repeat...

Страница 18: ...E PROPERLY LOADED BE SURE THAT TO MOBILE AND TO BASE PORTS ARE PROPERLY LOADED BE SURE THAT TO MOBILE AND TO BASE PORTS ARE PROPERLY LOADED BE SURE THAT TO MOBILE AND TO BASE PORTS ARE PROPERLY LOADED EITHER WITH 50 OHMS DUMMY LOADS EITHER WITH 50 OHMS DUMMY LOADS EITHER WITH 50 OHMS DUMMY LOADS EITHER WITH 50 OHMS DUMMY LOADS OR RADIATING SYSTEM OR RADIATING SYSTEM OR RADIATING SYSTEM OR RADIATIN...

Страница 19: ... 03 09 August 2010 14 4 Windows will start its hardware installation assistant follow the steps and indicate the driver location Select No not this time Select Install from a list or specific location Advanced ...

Страница 20: ...UM 0100 03 09 August 2010 15 Windows probably complains because this is not an official Microsoft Windows driver click in Continue Anyway ...

Страница 21: ...UM 0100 03 09 August 2010 16 5 After having installed the CDC RS232 Fiplex driver run pFOMS Software Click Connect ...

Страница 22: ...ose Select The Serial Com port that just appeared on your PC Remember that the BDA driver installs itself as a generic Com Port so if properly installed you should have a new comport not present before connecting the Repeater Click Continue ...

Страница 23: ...UM 0100 03 09 August 2010 18 Choose Flow Control None Click Accept This window will be active while Repeater is establishing connection with pFOMS ...

Страница 24: ... repeater this information is stored at repeater s firmware Device Information four fields at the upper right of the window displays static nominal values of the repeater this information are shown by pFOMS after detecting repeater model Gain these fields allow user to know actual manual attenuation AGC and effective gain of repeater this is dynamic information constantly and automatically being u...

Страница 25: ... be purple Band selective programmable filters shows Start Stop channel and Start Stop frequency Channel selective programmable filters will only show Start channel in this case the meaning for start channel is filter center BW channel Band selective fixed filters will show start frequency or channel and the meaning is center BW frequency or channel Manual attenuation shows the status of uplink an...

Страница 26: ...anual attenuation UL and or DL and filters user must click Edit at the bottom right corner of Status tabsheet Now user is free to change configurable values Once configured operational parameters click Accept after a few seconds changes will be displayed once pFOMS refresh the window with updated information ...

Отзывы: