FIPLEX • Electromagnetic Devices for Radiocommunication Systems
FIPLEX BIDIRECTIONAL AMPLIFIER - USER MANUAL
REMOTE CONTROL MODULE (RC)
Remote control module has an RS-232 interface with a D-Sub type 9 posittions
male connecto labeled as “NOTEBOOK” that allows a notebook conection by means of a
DB9 female straight cable.
Configuration of the repeater can be accomplished using BDA Local Management
Software (please see BDA LOCAL MANAGEMENT SOFTWARE section for further
details).
A modem conection is also available in the same module allowing the repeater to
be controlled and configured remotely by means of a wireless conection.
This module is able to work under mains failure condition by means of its own
backup battery, allowing the repeater to report this critical condition.
Backup battery must be enabled taking the jumper to the “ENABLE” position (see
above figure), factory default condition is disabled.
Battery provides autonomy of approximately 3 hours of continuous operation
approximately.
17
Document FIP-BDAM-07-EN