FIP FLS F3.00.W Скачать руководство пользователя страница 12

12

INSTALLATION FITTINGS

Type

Description

Plastic Tees

• Size: d20 to d50 (0.5” to 1.5”)

• Materials: PVC, C-PVC, PP, PVDF

PVC-U Clamp Saddles

• Size: d63 to d225 (2” to 8”)

• Insert Materials: C-PVC, PVDF

316L SS Tees

• Size: d63 to d315

• Materials: PVC, C-PVC, PP, PE

Metal Strap-on Saddles

• Size: DN80 to DN450

• Insert Material: C-PVC

• Special order for other sizes

316L SS Weld-on Adapters

• Size: d50 to d600 (1.5” to 24”)

Содержание FLS F3.00.W

Страница 1: ...all associated instrument manuals before using with it Product installation and wiring connections should only be performed by qualified staff Do not modify product construction To optimize the system functionality please refer to section System location Installation and Commissioning Statements Remove power to the instrument before wiring input and output connections Do not exceed maximum specifi...

Страница 2: ...ELECTRIC AND ELECTRONIC EQUIPMENT This product falls under the field of application of Directive 2012 19 EU concerning electric and electronic equipment waste management WEEE The equipment must not be discarded with domestic waste since made up of various materials that can be recycled at suitable centres Apply to your town authorities as to the location of disposal sites that can receive the prod...

Страница 3: ...mA Output signal for flow and for signal lack square wave frequency 45Hz per m s nominal 13 7 Hz per ft s nominal type transistor NPN open collector Output signal for low battery type NPN open collector max pull up voltage 24V DC max current 50mA battery level 0VCC low battery VCC fully charged Environmental Operating temperature 20 to 70 C 4 to 158 F Storage temperature 30 to 80 C 22 to 176 F Rel...

Страница 4: ...um Operating Pressure Temperature 25 years lifetime CPVC body 10 bar 145 psi 25 C 77 F 1 5 bar 22 psi 80 C 176 F PVDF body 10 bar 145 psi 25 C 77 F 2 5 bar 36 psi 100 C 212 F SS body 25 bar 363 psi 100 C 212 F ...

Страница 5: ...r To identify the proper position please refer to the FIP mark on the box cap Receiver must face the left side of FIP mark see the image below A Sensor body B F3 00 W Paddlewheel Flow transmitter C Receiver PCB D Receiver DIN bar adapter 1 Sensor body PVCC PVDF 316L SS 2 O Ring EPDM or FPM 3 Halar Rotor Ceramic shaft bearings for PVDF and PVC C version and 316 SS shaft for metal version 4 ABS cap ...

Страница 6: ... transmitter and receiver HIGH the level of signal is good and safe To connect with PLC Check the signal strength Put the JUMPER in the SIGNAL TEST position as indicated in the image below Connect with digital input as indicated in the section POWER WIRING DIAGRAM Set the PLC considering the following correspondence between the output frequency and the signal intensity 100Hz the level of signal is...

Страница 7: ...rement the sensor can NOT be exposed to air bubbles at any time The three installations in Fig 3 should be avoided unless you are absolutely sure the sensor is not exposed to air bubbles In gravity flow systems the connection to the tank must be designed so the level does not drop below the outlet this to avoid pipe to draw air in from the tank causing a inaccurate measurement of sensor see Fig 4 ...

Страница 8: ... Fig 2 can be chosen in case air bubbles are not present Do not mount the sensor on the bottom of the pipe Fig 1 if sediments are likely Do not mount paddlewheel at 90 otherwise friction can affect measurement Installation in a vertical pipe runs can be done fixing any orientation Upward flow is preferred to ensure full pipe Process connection 1 Lubricate the sensor O rings with a silicone lubrica...

Страница 9: ...unted 4 Install the PCB according to the picture Installation on the upper part of the box is reccommended DIN bar adapter 1 Remove the external fins following the dotted line indication on the receiver PCB see figure 1 2 assemble the receiver PCB following the sequence in the figure 2 Fig 1 REMOVABLE PART REMOVABLE PART CUTTING LINE CUTTING LINE Fig 2 ...

Страница 10: ...ed when connecting more than one wire to a single terminal Remove the upper part of the terminals for an easy cabling Insert wire tip or ferrule completely into the terminal and fix with the screw until finger tight Do not route the sensor or DC power in conduit containing AC power wiring Electrical noise may interfere with sensor signal Routing the sensor cable in grounded metal conduit can help ...

Страница 11: ...on to a PLC Connection to FLS M9 03 M9 07 and M9 08 monitors Connection for signal intensity function JUMPER IN SIGNAL TEST POSITION Please note on M9 02 M9 03 M9 07 and M9 08 DIR is the connection for low battery alarm Connection to FLS M9 03 monitor sensor input 1 ...

Страница 12: ... PVC C PVC PP PVDF PVC U Clamp Saddles Size d63 to d225 2 to 8 Insert Materials C PVC PVDF 316L SS Tees Size d63 to d315 Materials PVC C PVC PP PE Metal Strap on Saddles Size DN80 to DN450 Insert Material C PVC Special order for other sizes 316L SS Weld on Adapters Size d50 to d600 1 5 to 24 ...

Страница 13: ...VC 150 160 2 69 SVIC200DVC 180 200 1 65 SVIC225DVC 200 225 1 28 SMIC250IVC 225 250 1 01 SMIC280IVC 250 280 0 79 SMIC315IVC 280 315 0 61 ISO Metric PVC Tee Fittings for ISO SDR 21 pipes female ends for solvent welding Part No DN d K Factor TFIV20B 15 20 235 45 TFIV25B 20 25 142 46 TFIV32B 25 32 91 53 TFIV40B 32 40 51 57 TFIV50B 40 50 42 89 TFIV20D 15 20 235 45 TFIV25D 20 25 142 46 TFIV32D 25 32 91 ...

Страница 14: ...AC4 0DVM 4 00 6 47 SVAC5 0DVM 5 00 4 00 SVAC6 0DVM 6 00 2 68 SVAC8 0DVM 8 00 1 46 NPT Female Threaded PVC Tee Fittings for ASTM SCH 80 pipes NPT threaded female ends Part No SIZE R K Factor TFNV20B 0 50 1 2 235 45 TFNV25B 0 75 3 4 142 46 TFNV32B 1 00 1 91 53 TFNV40B 1 25 1 1 4 51 57 TFNV50B 1 50 1 1 2 42 89 TFNV20D 0 50 1 2 235 45 TFNV25D 0 75 3 4 142 46 TFNV32D 1 00 1 91 53 TFNV40D 1 25 1 1 4 51 ...

Страница 15: ... Female Threaded PP Tee Fittings for BS pipes parallel threaded female ends Part No DN R K Factor TFFM20B 15 1 2 212 17 TFFM25B 20 3 4 135 32 TFFM32B 25 1 89 36 TFFM40B 32 1 1 4 48 94 TFFM50B 40 1 1 2 42 10 TFFM20D 15 1 2 212 17 TFFM25D 20 3 4 135 32 TFFM32D 25 1 89 36 TFFM40D 32 1 1 4 48 94 TFFM50D 40 1 1 2 42 10 ISO Clamp Saddles for ISO SDR 21 pipes Part No DN d K Factor SVIC063BVC 50 63 21 69 ...

Страница 16: ...5 140 4 49 SVIC160BME 150 160 3 38 SVIC200BME 180 200 2 07 SVIC225BME 200 225 1 60 SVIC063DME 50 63 27 50 SVIC075DME 65 75 18 56 SVIC090DME 80 90 12 44 SVIC110DME 100 110 7 59 SVIC125DME 110 125 5 77 SVIC140DME 125 140 4 49 SVIC160DME 150 160 3 38 SVIC200DME 180 200 2 07 SVIC225DME 200 225 1 60 SMIC250IME 225 250 1 27 SMIC280IME 250 280 0 99 SMIC315IME 280 315 0 77 ASTM SCH 80 Clamp Saddles for AS...

Страница 17: ...50 63 20 58 SVIF 075BF 65 75 14 09 SVIF 090BF 80 90 9 29 SVIF 110BF 100 110 5 69 SVIF 125BF 110 125 4 31 SVIF 140BF 125 140 3 36 SVIF 160BF 150 160 2 52 SVIF 200BF 180 200 1 55 SVIF 225BF 200 225 1 20 SVIF 063DF 50 63 20 58 SVIF 075DF 65 75 14 09 SVIF 090DF 80 90 9 29 SVIF 110DF 100 110 5 69 SVIF 125DF 110 125 4 31 SVIF 140DF 125 140 3 36 SVIF 160DF 150 160 2 52 SVIF 200DF 180 200 1 55 SVIF 225DF ...

Страница 18: ... SZIC250I 250 0 75 SZIC300I 300 0 52 SZIC350I 350 0 43 SZIC400I 400 0 32 SZIC450I 450 316L SS Weld on Adapters mounted on Other Metal pipes Part No DN K Factor WAIXL0 40 36 17 WAIXL0 50 23 71 WAIXL0 60 WAIXL0 65 13 93 WAIXL0 80 9 61 WAIXL0 100 5 22 WAIXL0 110 WAIXL0 125 3 31 WAIXL0 150 2 22 WAIXL0 175 WAIXL0 200 1 23 WAIXL1 225 0 75 WAIXL1 250 0 52 WAIXL1 300 0 43 WAIXL1 350 0 32 WAIXL1 400 WAIXL1...

Страница 19: ...15 Hall See electrical data section L1 CPVC EPDM IP65 0 15 to 8 m s 0 5 to 25 ft s 800 F3 00 W 16 Hall See electrical data section L1 CPVC FPM IP65 0 15 to 8 m s 0 5 to 25 ft s 800 F3 00 W 17 Hall See electrical data section L0 PVDF EPDM IP65 0 15 to 8 m s 0 5 to 25 ft s 750 F3 00 W 18 Hall See electrical data section L0 PVDF FPM IP65 0 15 to 8 m s 0 5 to 25 ft s 750 F3 00 W 19 Hall See electrical...

Страница 20: ...FIP Formatura Iniezione Polimeri S p A Loc Pian di Parata 16015 Casella Genova Italy Tel 39 010 96211 Fax 39 010 9621209 www flsnet it I2445 IMF300WE REV 01 05 2020 ...