![Fiori E81 AQUA Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/fiori/e81-aqua/e81-aqua_user-manual_2290582006.webp)
6
Mounting and replacing the carbon filter:
a)
Disconnect the hood from the electricity.
b)
Remove the metal grease filters (Fig. 1).
c)
If the filters have not been installed, place one
filter on each side so that they cover the grates
protecting the rotor on the motor. Then turn the
center handle for the filters in the clockwise
direction (Fig. 2).
d)
If the charcoal filters have already been
installed (covering the grates protecting the
rotor on the motor) and must be replaced, turn
the central handle in the counter-clockwise
direction until the filters are unlocked.
e )
Refit the the metal grease filters.
Cleaning
To clean the outside of the hood use a cloth
moistened with denatured alcohol or neutral liquid
detergents. Never use products containing
abrasive.
Wipe brushed stainless steel in the same direction
as the brushing to avoid scratching.
Attention
Failure to observe the rules for cleaning the
appliance and changing and cleaning the filters
may cause fires.
Therefore, we recommend observing these
instructions.
Replacing the lamp
a)
Disconnect the hood from the electricity.
b)
Unscrew the light shield (Fig. 3).
c)
Replace the damaged lamp with a new halogen
lamp of 20 Watt max.
d)
Refit the the metal grease filters and the light
shield.
e )
Before calling for repair service because the
hood fails to light up, make sure the bulbs are
screwed in tightly.
Use:Two systems are available
Exhaust mode (S)
Vapors are extracted outside through an exhausting pipe that is
affixed to the connectionring above the hood.Diameter of the
exhausting pipe must be equal tothat of the connection ring.
Attention!
If the hood is supplied with carbon filter,then it must be removed.
Filter version (K)
The air is filtered through a carbon filter (for itsinstallation see
paragraph "Carbon filter") andrecirculated into the room through
the grating onthe lower side of the chimney.
Attention!
If the hood is not supplied with carbonfilter, then it must be
ordered and mounted.
This version is used when there is no exhaustduct for venting
outdoors or when it is impossibleto install one.