A. Installation 

 

This controller is installed inside the steam room only,  and it comes 
with a built-in temperature sensor.  The best location for the control is 
close to your bench for easy access,  also further away from steam 

head.  It is recommended to install the control pad from 36" up to the 
maximum 48" height.  

 

Note:

 

The controller is provided with a 25 ft standard-length connector 

cable.  If you need to extend up to 50 ft, use 4-core wires (22 to 18 AWG). 

 

B. Operation 

Programme for temperature setpoint and time setting. 

 
1.

 

Power Sign

:  Turns on or shut off the steam. When the control is in standby mode, the power 

light stays on. 

 

2.

 

Temperature control

:  Controls the temperature set point in the steam room, which can set 

from 10°C(50°F) to 85°C(185°F). To change the temperature setpoint, just touch the 

TEMP

 

sign for 3 seconds, while the control is on, then use the 

 (Up) or 

 (Down) to set it to desired 

value (hold it to change faster), touch the 

ENTER

 to save it. 

 

3.

 

Time control

:  Controls the duration of steam operation, which can be set from 5 to 90 

minutes in 1-minute increments.  The unit will work until it times out.  To change the time 

setting, Touch the 

TIME

 sign for 3 seconds while the control is on, then use the 

 (Up) or 

 

(Down) to set it on desired time (hold it to change faster), touch the 

ENTER 

to save it. 

 

4.

 

Temperature/Time display

:  When the control is turned on, it displays the current 

temperature in the steam room; By simply touch the temperature / time sign to switch the 
display on temperature or time. On the time display, it will show the minutes counting down. 

 

5.

 

Celsius to Fahrenheit:  

To switch the display reading between Celsius and Fahrenheit, first, 

turn off the control.  Then touch the 

TEMP

 sign until the "F" or “C” turns on the display. 

 
6.

 

Lights (LEDs)

: There are 5 lights around the 

display, each indicating a status:    

 

-

 

Power:

  is on as control is off in standby mode. 

-

 

TEMP: 

 is on when there is a call for steam. 

-

 

TIME:

  is on when timer is still counting down.  

-

 

°c: 

 is on when temperature is set for Celsius. 

-

 

°f: 

 is on when temp. is set for Fahrenheit. 

 

7.

 

Default Setpoints:  

The control goes back to the 

following default settings if the power is interrupted. 

 

 

Temperature defaults:  47°C (117°F). 

 

Set range:  (10 to 85°C)/(50 to 185°F). 

 

Time default:  30 minutes. 

 

 

Set range:  5 to 90 minutes. 

FiNO Control -  Glass Touch 

 

Содержание CS 11

Страница 1: ... E EN N NE E ER R RA A AT T TO O OR R RS S S I I IN N NS S ST T TA A AL L LL L LA A AT T TI I IO O ON N N O O OP P PE E ER R RA A AT T TI I IO O ON N N A A AN N ND D D M M MA A AI I IN N NT T TE E EN N NA A AN N NC C CE E E M M MA A AN N NU U UA A AL L L ...

Страница 2: ...has been tested and approved by CSA and listed with UL also manufactured as per ISO 9001 2008 Quality Management System so you are assured of the highest quality and safety standard This manual is a comprehensive guide to proper installation operation and maintenance of your RS CS and RV Series steam units It covers the following Models RS Series CS Series CS Large RV Series RS 50 CS 11 CS 18 RV 9...

Страница 3: ... CS12 12 240 1 50 6 400 550 25 x9 x10 30 lbs CS13 13 240 1 55 6 450 600 25 x9 x10 30 lbs CS15 15 240 1 63 4 500 700 25 x9 x10 30 lbs CS18 18 240 1 75 3 600 800 25 x9 x10 30 lbs CS24 24 240 1 100 1 03 up to 1200 25 x9 x18 60 lbs CS30 30 240 1 125 2 02 up to 1500 25 x9 x18 60 lbs CALCULATE THE STEAM ROOM S VOLUME V in cubic feet by multiplying its length x width x height in feet Based on the constru...

Страница 4: ...ture off JP2 Open External timer with or without button Close Only E Touch button with 30 min built in timer JP3 Open Digital Timer Connectors CN1 240V AC Input Power CN2 Output Connector CN3 Mechanical or digital timer input CN4 Water Level Probe CN5 E Touch Button Connector Not Used Only with special instructions from the manufacturer INSTALLATION GUIDE ...

Страница 5: ...se to the unit Before connecting water line to the unit flush the line into a pail or drain to free it of any plumbing residue After it is thoroughly flushed attach the water line to the inlet line on the unit and open the water supply Check for any leaks If the water supply minerals are high refer to Filtration section in the end of this manual Step 2 Steam Connection A compression fitting is sup...

Страница 6: ...equipment failure or personal injury and the warranty will be null and void For all models please note the following steps When you need to shut down the power 1 Turn off the unit at the timer 2 Wait for 15 30 seconds 3 Shut down the main power supply Failure to do this may cause the microprocessor to malfunction 1 Read all instructions in this guide prior to installing your steam generator 2 Alwa...

Страница 7: ...r Clean water level probe Calcium mineral build up send back to refurbish Water comes from steam head when Power on Power off Water Level Probe faulty Heating element burnt Dirt on solenoid seat Clean water level probe Check power leakage on Ground wire replace heating element Clean solenoid valve clean filter Thumping noise when unit is running Water hammer on inlet Water condensing on steam line...

Страница 8: ...h can be set from 5 to 90 minutes in 1 minute increments The unit will work until it times out To change the time setting Touch the TIME sign for 3 seconds while the control is on then use the Up or Down to set it on desired time hold it to change faster touch the ENTER to save it 4 Temperature Time display When the control is turned on it displays the current temperature in the steam room By simp...

Страница 9: ...on Operation Maintenance Manual 8 Touch to turn on and shut off steam with blue LED indicator light Touch to turn on and shut off steam with blue LED indicator light LED STONE TOUCH BUTTON LED PUSH BUTTON STEAM HEADS ...

Страница 10: ... as a secondary system However even if there is a water softener set up on the house water other than R O System it is set up to accommodate only the heating of water and not the boiling of water A secondary small softener dedicated to the steam generator is generally recommended It will need to be set up slightly differently than the house softener so that it strips all mineral impurities from th...

Страница 11: ...FINO Installation Operation Maintenance Manual 10 ...

Отзывы: