background image

FINO

®

 Installation, Operation & Maintenance Manual  

 

 

 
 

Symptoms

 

Possible cause

 

Possible Solution

 

New unit does not produce 
steam after it is connected

 

- Water is shut off 
- Electrical Power is off 
 

- Timer is not set 
- Thermostat not set 
 

- Unit not installed 

correctly 

- Not connected properly 

- Ground terminal 

connected with neutral 

Thermostat sensor loose 

   Connection 
- Temperature setting 

lower than room temp.  

- Damage in shipping 

 

- Turn on water supply 
- Turn on power. Check circuit 

breaker. 

- Turn on timer 
- Adjust thermostat to desired 

temperature 

- See Installation Guide & 

Instructions on page 3 & 4. 

- Check wiring 

- Connect Ground Wire to the 

Ground Terminal. 

- Connect sensor to control panel 

have room temp on display. 

- Increase temperature set point 

over the room temperature 

- Contact manufacturer 
 

Used unit not producing 
steam

 

- No power 
- Power is on, not working 
- Water filter clogged  

- Water keep running 
- Drain valve stuck open  
- Element burned out 

- Contactor not engage 
- Water level probe faulty 
- Unit not produce enough  

steam.

 

- Check & reset circuit 
- Check & replace 1A/250V fuse 
- Replace or clean filter 

- Open & clean inlet valve 
- Open & clean drain valve  
- Replace element 

- Check resistance on contactor 
- Clean water level probe 
- Calcium & mineral build up, send  

   back to refurbish.

 

Water comes from steam 
head when    * Power on 
                      

                    * Power off 

- Water Level Probe faulty 
- Heating element burnt 
 

- Dirt on solenoid seat

 

- Clean water level probe 
- Check power leakage on Ground   
   wire, replace heating element 

- Clean solenoid valve, clean filter

 

Thumping noise when unit 

is running. 
 

 

- Water hammer on inlet 

 
- Water condensing on  
   steam line 

- Contactor buzzing noise 

 

- Install water hammer suppressor  

  or flex in lieu of 

1/4"

 copper tube. 

- Find out low points, replace pipe 
 

- Replace contactor 

Unit does not drain; 
Water runs through drain 
valve continuously 

- Drain stuck open 
- Seal broken  
- Drain plugged  

- Manual drain optio 

- Open valve & clean up  
- Install rebuilt kit  
- Open & clean valve 

- Manually drain it after each use. 

Unit heats but does not 

produce sufficient steam

 

- Drain valve stuck open 

and water leak through 

- Heating element burnt  
- Unit too small

 

- Clean valve 

 
- Replace heating element  
- Upgrade to larger unit

 

Steam room too hot, steam 

dissipates

 

- Thermostat sensor not 

properly placed 

- Temperature setting 

wrong

 

- Relocate sensor 

 
- Check the temperature setting 

 

Steam room not hot enough 
 

 

 

- Thermostat sensor not 

properly placed 

- Steam line may too long 
- Temperature set too low 
- Improper sized unit

 

- Relocate sensor 
 

- Insulate steam line 
- Increase temperature set point 
- Contact manufacturer

 

BASIC TROUBLE SHOOTING GUIDE 

Содержание CS 11

Страница 1: ... E EN N NE E ER R RA A AT T TO O OR R RS S S I I IN N NS S ST T TA A AL L LL L LA A AT T TI I IO O ON N N O O OP P PE E ER R RA A AT T TI I IO O ON N N A A AN N ND D D M M MA A AI I IN N NT T TE E EN N NA A AN N NC C CE E E M M MA A AN N NU U UA A AL L L ...

Страница 2: ...has been tested and approved by CSA and listed with UL also manufactured as per ISO 9001 2008 Quality Management System so you are assured of the highest quality and safety standard This manual is a comprehensive guide to proper installation operation and maintenance of your RS CS and RV Series steam units It covers the following Models RS Series CS Series CS Large RV Series RS 50 CS 11 CS 18 RV 9...

Страница 3: ... CS12 12 240 1 50 6 400 550 25 x9 x10 30 lbs CS13 13 240 1 55 6 450 600 25 x9 x10 30 lbs CS15 15 240 1 63 4 500 700 25 x9 x10 30 lbs CS18 18 240 1 75 3 600 800 25 x9 x10 30 lbs CS24 24 240 1 100 1 03 up to 1200 25 x9 x18 60 lbs CS30 30 240 1 125 2 02 up to 1500 25 x9 x18 60 lbs CALCULATE THE STEAM ROOM S VOLUME V in cubic feet by multiplying its length x width x height in feet Based on the constru...

Страница 4: ...ture off JP2 Open External timer with or without button Close Only E Touch button with 30 min built in timer JP3 Open Digital Timer Connectors CN1 240V AC Input Power CN2 Output Connector CN3 Mechanical or digital timer input CN4 Water Level Probe CN5 E Touch Button Connector Not Used Only with special instructions from the manufacturer INSTALLATION GUIDE ...

Страница 5: ...se to the unit Before connecting water line to the unit flush the line into a pail or drain to free it of any plumbing residue After it is thoroughly flushed attach the water line to the inlet line on the unit and open the water supply Check for any leaks If the water supply minerals are high refer to Filtration section in the end of this manual Step 2 Steam Connection A compression fitting is sup...

Страница 6: ...equipment failure or personal injury and the warranty will be null and void For all models please note the following steps When you need to shut down the power 1 Turn off the unit at the timer 2 Wait for 15 30 seconds 3 Shut down the main power supply Failure to do this may cause the microprocessor to malfunction 1 Read all instructions in this guide prior to installing your steam generator 2 Alwa...

Страница 7: ...r Clean water level probe Calcium mineral build up send back to refurbish Water comes from steam head when Power on Power off Water Level Probe faulty Heating element burnt Dirt on solenoid seat Clean water level probe Check power leakage on Ground wire replace heating element Clean solenoid valve clean filter Thumping noise when unit is running Water hammer on inlet Water condensing on steam line...

Страница 8: ...h can be set from 5 to 90 minutes in 1 minute increments The unit will work until it times out To change the time setting Touch the TIME sign for 3 seconds while the control is on then use the Up or Down to set it on desired time hold it to change faster touch the ENTER to save it 4 Temperature Time display When the control is turned on it displays the current temperature in the steam room By simp...

Страница 9: ...on Operation Maintenance Manual 8 Touch to turn on and shut off steam with blue LED indicator light Touch to turn on and shut off steam with blue LED indicator light LED STONE TOUCH BUTTON LED PUSH BUTTON STEAM HEADS ...

Страница 10: ... as a secondary system However even if there is a water softener set up on the house water other than R O System it is set up to accommodate only the heating of water and not the boiling of water A secondary small softener dedicated to the steam generator is generally recommended It will need to be set up slightly differently than the house softener so that it strips all mineral impurities from th...

Страница 11: ...FINO Installation Operation Maintenance Manual 10 ...

Отзывы: